Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
From version 87.4
edited by Hunter
on 2024/02/19 11:18
on 2024/02/19 11:18
Change comment:
There is no comment for this version
To version 80.1
edited by Jim(Forgotten)
on 2023/08/11 09:26
on 2023/08/11 09:26
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Jim - Content
-
... ... @@ -17,29 +17,29 @@ 17 17 18 18 **Read-write** 19 19 20 -* **Write Address: **Bit address operation control for HMI or PLC. 21 -* **Read**: Enable the monitoring the read address or not. 22 -* **Same read-write address**: Enable it if want to the read address and write address is exactly same. 23 -* **Read Address: **Monitoring address. 20 +* **Write Address: **Bit switch controls PLC or HMI address. 21 +* **Read Address: **Read and display PLC or HMI bit address state. 24 24 25 25 **Mode** 26 26 27 -* **Set OFF:** Set off the write address.28 -* **Set ON:** Set on the write address.29 -* **Momentary:** Set on the write address when switch is pressed, andresettheaddresswhen switch is released.30 -* **Delay: Intervalfor keeponthe write address.For example:Assign the delay time as 500, write address will bereset after release buttonin0.5 second.31 -* **Switch:** Switch betweenTrue(1)andFalse(0)whenswitch is triggered.25 +* **Set OFF:** set off the write address. 26 +* **Set ON:** set on the write address. 27 +* **Momentary:** set on the write address when switch is pressed, and set off when switch is released. 28 +* **Delay:** set off the write address after a delay. (for example: assign the delay time as 5, write address will be set off after releasing 5 ms.) 29 +* **Switch:** switch between 0 and 1 each time the switch is triggered. 32 32 33 33 **Display** 34 34 35 35 * **Inverted Display: **Display the state picture and text of the object reversely. 36 -* **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 37 -* **Blink: **Control the state of blink by the bit address of control bit. Blinking while control bit is triggered, the frequency is editable; 38 -** **Blink when ON: **blink when control bit is ON. 39 -** **Blink when OFF: **blink when control bit is OFF. 34 +* **Quick Read: **The speed of configuring the object is priority to other objects. 40 40 41 -** Minimum hold time: **Onlywhenthe time ofpress andholdtheobjectis greater thanthesetvalue, theobjectfunctionwillbeexecuted.36 +**Blink: **Control the state of blink by the bit address of control bit. Blinking while control bit is triggered, the frequency is editable; 42 42 38 +* **Blink when ON: **blink when control bit is ON. 39 +* **Blink when OFF: **blink when control bit is OFF. 40 + 41 +**Minimum hold time: **Only when the time of pressing the object is greater than or equal to the set minimum hold time will the function of the object be performed. 42 + 43 43 **Indirect addressing:** 44 44 45 45 * **Read address**: Use the value of the read address to determine the address A after deviation, and use the address A as the read address of the object. ... ... @@ -103,19 +103,6 @@ 103 103 (% style="text-align:center" %) 104 104 [[image:位开关 6.png||class="img-thumbnail"]] 105 105 106 -**No trigger:** No way to trigger 107 - 108 -**Trigger before pressing:** Trigger bit address is set to 1 before pressing 109 - 110 -**Trigger after pressing: **After pressing Enter, trigger bit address is set to 1 before closing the keyboard 111 - 112 -**Trigger and reset before pressing: **Trigger bit address is set to 1 and then set to 0 bedore pressing 113 - 114 -**Trigger and reset after pressing: **After pressing Enter, trigger bit address is set to 1 and then set to 0 before closing the keyboard 115 - 116 -**Trigger before pressing, reset after: **Trigger bit address is set to 1 before pressing; After pressing Enter, trigger bit address is set to 0 before closing the keyboard 117 - 118 - 119 119 **Access denied setting** 120 120 121 121 Users can set enable password for object. There are following operating setting when user permissions are insufficient. But "Pop login screen" and "Hide object" are mutually exclusive. ... ... @@ -199,20 +199,18 @@ 199 199 (% style="text-align:center" %) 200 200 [[image:6.Objects_html_273aed06eb8f10f9.gif||class="img-thumbnail"]] 201 201 202 -**Address**: Monitoringand displaytheaddressstatus.189 +**Address**: It is for setting specified PLC or HMI bit address。 203 203 204 204 **Hide** 205 205 206 -* **Inverted Display: **Display reverse state of the picture and text. For example, the value of write address is on (Corresponding to state 1), while the graphic of off (Corresponding to state 0) is displayed. 207 -* **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 208 -* **Blink: **Blink condition; 209 -** Blink when ON: blink when read address is ON. 210 -** Blink when OFF: blink when read address is OFF. 211 -* **Hide: **Control the hide status of object via Control Bit's state. Hide object cannot be operated at all. 212 -* **Control Bit: **Hide condition. 213 -** **Hide when OFF**: Hide when control bit is OFF. 214 -** **Hide when ON**: Hide when control bit is ON. 215 -** **Invisible:** Object is always keeps hidden during project running. 193 +* **Inverted Display: **Display reverse state of the picture and text. *for example, the value of write address is set ON, the OFF mode is displayed. 194 +* **Blinking: **Blinking while control bit is triggered, the frequency is editable; 195 +** Blink when ON: blink when control bit is ON. 196 +** Blink when OFF: blink when control bit is OFF. 197 +* **Hide: **Display or hide object by "Control Bit" state. 198 +* **Control bit: **For hide control. 199 +** **Hide mode: **hide when OFF; hide when ON;it could not operate if [Invisible] is checked. 200 +** **Invisible:** object keeps hidden during project running. 216 216 217 217 (% class="box infomessage" %) 218 218 ((( ... ... @@ -1372,10 +1372,7 @@ 1372 1372 ** **History**: It is in data record area configured by data record. Multiple record groups could be configured, and each record group has multiple channels. 1373 1373 ** **Real Time**: It is in Real-time trend chart configured by data record. Multiple record groups could be configured, and each record group has multiple curve numbers. 1374 1374 1375 -(% class="box infomessage" %) 1376 -((( 1377 1377 **✎Note: **There must be one of settings (Data record and real-time trend chart) in configurations, otherwise there will be no data in curve buffer. 1378 -))) 1379 1379 1380 1380 * **Curve No.**: The number of curves is the same as the number of channels in the record group. A maximum of 8 curves could be displayed. After selecting the curve to be displayed, it can set the scale range and scale color of each curve. 1381 1381 * **Enable**: After selecting the corresponding curve number in the status bar and enabling the curve, set different curve styles and colors according to your needs, then select the channel number in the data buffer, and finally set the data range. ... ... @@ -1409,10 +1409,7 @@ 1409 1409 **Function start Address**: Open the sub-screen of the data record query, and the system can automatically allocate the object address of the query screen according to the configured address. When using this component, it will automatically generate buttons for four direction, you can use these four control keys to view the data record display, and automatically create a new sub-screen based on the function start address, the content of the sub-screen is the query setting for span and start time. 1410 1410 When two objects use one function screen at the same time, if the function addresses of the two object are the same, changing the built-in screen will affect the operation of the two display object at the same time. If the function addresses of the two objects are different, the second object with the built-in screen can be displayed normally, and the first object will be displayed abnormally. 1411 1411 1412 -(% class="box infomessage" %) 1413 -((( 1414 1414 **✎Note: ** When copying Data record display, it is recommended to create a new "function screen" to avoid repeated calls that may cause abnormal functions. 1415 -))) 1416 1416 1417 1417 **Start time**: Set the start time and conditions for data viewing. 1418 1418 ... ... @@ -1597,10 +1597,7 @@ 1597 1597 (% style="text-align:center" %) 1598 1598 [[image:6.Objects_html_9612d7685f349400.gif||class="img-thumbnail"]] 1599 1599 1600 -(% class="box infomessage" %) 1601 -((( 1602 1602 ✎**Note:** For the "Text" setting, please refer to "[[text>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fview%2FHelps%2F06.Objects%2F%23HText]]" in "[[Bit Switch>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fedit%2FHelps%2F06.Objects%2FWebHome%3Fsection%3D2]]". 1603 -))) 1604 1604 1605 1605 = **Display** = 1606 1606 ... ... @@ -1663,14 +1663,11 @@ 1663 1663 1. **Variable QR:** It is for setting read address, the content of QR code is from this setting address. 1664 1664 1. **QR String: **It is for set static content for QR code. 1665 1665 1666 -(% class="box infomessage" %) 1667 -((( 1668 1668 **✎Note:** 1669 1669 1670 1670 * HMI machine ID address: HSW10494 ~~ HSW10558. 1671 1671 * So if user want to use QR code to display machine ID on project screen, please check "Variable QR", and set address is HSW10494. 1672 1672 * When scanning the QR code by APP to monitor HMI, the default access password is 888888. 1673 -))) 1674 1674 1675 1675 == **Picture** == 1676 1676 ... ... @@ -1699,13 +1699,10 @@ 1699 1699 1. **Folder: **Set the name of the folder where the picture is located.The folder name can be up to 31 characters. (Note:The picture must be stored in the U disk folder and cannot be stored in the root directory of the U disk.) 1700 1700 1. **File address: **16 consecutive addresses enter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed. 1701 1701 1702 -(% class="box infomessage" %) 1703 -((( 1704 1704 ✎**Note:** 1705 1705 1706 1706 1. The image could be displayed in BMP, JPG, PNG, and JPEG formats. Images with a resolution of 1920 x 1080 or higher are not supported. 1707 1707 1. For the setting of [[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 1708 -))) 1709 1709 1710 1710 == **Rotation picture** == 1711 1711 ... ... @@ -1829,12 +1829,9 @@ 1829 1829 1830 1830 Video display is advanced function in PI HMI, this object displays the camera screen in HMI, there are two modes, one is IP camera, and the other is USB camera. But IP camera requires settings in [Project settings], the detailed information, please refer to ~[[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__Camera__>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HCameradisplay]](%%)]. 1831 1831 1832 -(% class="box infomessage" %) 1833 -((( 1834 1834 **✎Note:** 1835 1835 1836 1836 This function requires special HMI model, the detailed information, please contact sales. 1837 -))) 1838 1838 1839 1839 === **IP Camera** === 1840 1840 ... ... @@ -2450,7 +2450,7 @@ 2450 2450 ** ASHU S300 (640*480 2451 2451 ))) 2452 2452 2453 -* 2420 +* \\ 2454 2454 2455 2455 == **Camera control** == 2456 2456 ... ... @@ -2626,10 +2626,8 @@ 2626 2626 English 2 2627 2627 ))) 2628 2628 2629 -(% class="box infomessage" %) 2630 -((( 2596 +(% class="wikigeneratedid" %) 2631 2631 ✎**Note:** For [[animations>>url:http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HAmination]], see the "[[Bit Switch>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fedit%2FHelps%2F06.Objects%2FWebHome%3Fsection%3D2]]". 2632 -))) 2633 2633 2634 2634 == **Time** == 2635 2635