Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -34,9 +34,9 @@ 34 34 35 35 * **Inverted Display: **Display the state picture and text of the object reversely. 36 36 * **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 37 -* **Blink: ** Control the state of blink by the bit address of control bit.Blinking while control bit is triggered, the frequency is editable;38 -** **Blink when ON: ** blink when control bit is ON.39 -** **Blink when OFF: ** blink when control bit is OFF.37 +* **Blink: **Blinking while control bit is triggered; 38 +** **Blink when ON: **Blink when control bit is ON. 39 +** **Blink when OFF: **Blink when control bit is OFF. 40 40 41 41 **Minimum hold time: **Only when the time of press and hold the object is greater than the set value, the object function will be executed. 42 42 ... ... @@ -153,7 +153,7 @@ 153 153 * Y-axis movement. 154 154 * XY-axis movement. 155 155 156 -**For ex **a**mple**156 +**For example** 157 157 158 158 If the starting address of the movement is HDW10 and the movement type is [XY axis movement], HDW10 controls the X-axis movement, and HDW11 controls the Y-axis movement. 159 159 ... ... @@ -230,21 +230,20 @@ 230 230 231 231 **Edit** 232 232 233 -* **Read address: **Read value from specified address. 233 +* **Read address: **Read value from object display. 234 +* **Same read-write address**: Enable it if want to the read address and write address is exactly same. 234 234 * **Write address: **Write value to specified address. 235 235 236 -Read and write address could be the same; 237 - 238 238 **Data format** 239 239 240 -* **Format**: It is for settingoperatingdata format;itcouldsupport sevenmodes.239 +* **Format**: Set the data format: 16bit BCD, 16bit Unsigned, 16bit Signed, 32bit BCD, 32bit Unsigned, 32bit Signed, 32bit Float. 241 241 242 -**Mode** . It is for setting operating mode for value, it could support 3 modes.241 +**Mode** 243 243 244 244 * **Set value: **Set a constant value for the word address. 245 -* **Increase: **Increase the [operand]value for each time the switch is triggered.246 -* **Decrease:** Decrease the [operand]value for each time the switch is triggered.247 -* **High/Low limit:** The value will not increase/decrease when the value reaches limits.244 +* **Increase: **Increase Operand value for each time the switch is triggered. 245 +* **Decrease:** Decrease Operand value for each time the switch is triggered. 246 +* **High/Low limit:** The value will be not able to change when the value reaches limits. 248 248 249 249 (% class="box infomessage" %) 250 250 ((( ... ... @@ -265,53 +265,45 @@ 265 265 266 266 **Address** 267 267 268 -* **Read address:** read the value from specified address. 267 +* **Read address:** Read the value from object display. 268 +* **States count: **Total status number for current word address, which could change the state value according to different status in button [State values], range: 1-256. 269 +* **State with value out of range**: When the value of the read address is not on the range of states' value, it will cause no corresponding status number is displayed. There are two modes for process when the value is out of range. 270 +* **Hide**: Hide the object when the value is out of range; 271 +* **Show state**: Specify a status when the value is out of range, for example the total states is 6(range from state No.0~~No.5), but the read value is 6, at this moment the object will show the state No.0 if selected item of show state is No.0; 269 269 270 -**States settings** 271 - 272 -* **States count: **The default Word state displays the number of States 1, which could be selected by the drop-down list to display the state of object, range: 1-256. 273 -* **State value: **Users could set different values to correspond to different states, the setting window as below figure shows. 274 - 275 275 **For example** 276 276 277 - Bydefault,whenvalueof read address is0, objectdisplaysstate0.275 +The state No.0 default fill value 0, No.1 default fill value 1... and so on. 278 278 279 279 If change settings as below figure shows 280 280 281 -When value of read address is 11, object displays state 1. 279 +When value of read address is 11, object displays state No.1. 282 282 283 283 (% style="text-align:center" %) 284 284 [[image:6.Objects_html_da9a6696f320b427.gif||class="img-thumbnail"]] 285 285 286 -**State of value out of range: **When the value of read address exceeds the maximum state number, there is no corresponding state to be displayed. So there are two modes of processing for it: "Hide" and "Show state" 287 - 288 -**Hide: **When the value of the read address exceeds the set range value, the word state display object will be blank. 289 - 290 -**Show state: **When the value of the read address exceeds the set range value, the object will display the "Specified state". For example, set the maximum is state 7 (value is 6), when the read address of the value is greater than 6, it will display state 2 text and pictures. 291 - 292 292 **Transform state** 293 293 294 -* **Quick Read: ** Directly read thevalueoftheconnecteddevice without goingthroughtheHMIcache286 +* **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 295 295 * **Auto transforms:** Object switch states automatically 296 296 297 297 (% style="text-align:center" %) 298 298 [[image:6.Objects_html_b643c9a6a4bd6919.gif||class="img-thumbnail"]] 299 299 300 -**Trigger:**Control bit to enable switch automatically 292 +* **Trigger to transform: **Trigger condition of auto transform 293 +* **Auto return:** Return to the initial state after reaching the final state; 294 +* **Time of transform:** Set the interval of transform between two states; 295 +* **Dynamic interval: **Set the dynamic interval of transform between two states. If the value in address is 10, then the frequency of automatic switching state is 10*100ms = 1s. 301 301 302 -* **Auto return:** return to the initial state after reaching the final state; 303 -* **Time of transform:** it is used for setting the frequency in automatic switching state. Unit: 100ms. 304 -* **Dynamic interval: **set the frequency of automatic switching state and read it from the address. Unit: 100ms. If the value in address is 10, then the frequency of automatic switching state is 10*100ms = 1s. 305 - 306 306 **Manual** 307 307 308 308 (% style="text-align:center" %) 309 309 [[image:6.Objects_html_a8b6636bd862369c.gif||class="img-thumbnail"]] 310 310 311 -* **Set state: **Set a constant value for thewordaddress.312 -* **State increase: **Increase stateforeach time the switchisriggered.313 -* **State decrease:** Decrease stateforeachtime theswitchistriggered.314 -* **Last state:** statewillnot increase/decreasewhen reaches limits.302 +* **Set state: **Set a constant value to address(according to the operate state selection) when click the object. 303 +* **State increase: **Increase the address value by one step when click the object, the upper limit is depends on the Last state selection. 304 +* **State decrease:** Decrease the address value by one step when click the object, the lower limit is depends on the Last state selection.. 305 +* **Last state: **The upper limit or lower limit(Final state) of state increase/decrease; 315 315 316 316 (% class="box infomessage" %) 317 317 ((( ... ... @@ -318,9 +318,9 @@ 318 318 ✎**Note:** For [[text>>https://docs.we-con.com.cn/bin/view/PIStudio/7.Library/#HText]]/[[graphics>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HGraphic]]/[[security>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HSecurity]]/[[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>path:https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 319 319 ))) 320 320 321 -== Keypad switch==312 +== Button == 322 322 323 - Keypad switchis designed to input datamanually;this object need to work with theKeypad.User could assignletters or numbers for eachswitch,whenthe switchis triggeredthe data will inputto the textbox.314 +Button is designed to input data into the corresponding inputbox, this object need to work with the numeric input and character input. 324 324 325 325 **Description** 326 326 ... ... @@ -338,7 +338,7 @@ 338 338 339 339 == Function switch == 340 340 341 -Function switch is designed to switch screens, and call and close sub screen, and transfer datarecord files.332 +Function switch is designed to switch screens, and call and close sub screen, and transfer record files. 342 342 343 343 **Description** 344 344 ... ... @@ -345,8 +345,6 @@ 345 345 (% style="text-align:center" %) 346 346 [[image:6.Objects_html_31c4ad387507a16d.gif||class="img-thumbnail"]] 347 347 348 -**Operation** 349 - 350 350 * **Screen No: **Switch to the selected screen, it could not be subscreen; 351 351 * **Open sub screen: **Pop-up selected sub screen, and set sub screen position, default position is (0, 0), this is the coordinates of the top left corner of the screen; 352 352 ... ... @@ -375,7 +375,7 @@ 375 375 376 376 **Using trigger address**. As the figure above, when 00 is ON, then selected operation of the function switch will be executed. 377 377 378 -**All terminals effect** .When this function is enabled, all terminals (screens, mobile phones, ipads, computers, etc.) will execute the function Switch Function simultaneously. For example, the screens of each terminal are different. When the screen is clicked to jump to the "Home" screen, all terminals will jump to the home screen.367 +**All terminals effect**: When this function is enabled, all terminals (screens, mobile phones, ipads, computers, etc.) will execute the function Switch Function simultaneously. For example, the screens of each terminal are different. When the screen is clicked to jump to the "Home" screen, all terminals will jump to the home screen. 379 379 380 380 (% class="box infomessage" %) 381 381 ((( ... ... @@ -395,13 +395,11 @@ 395 395 396 396 == Combination switch == 397 397 398 -The combination switch supports thecollectionofmultiple functions onto oneobject. When the object is pressed, multiple functions arearranged in sequence to meet thespecialrequirements of the user.387 +The combination switch supports combine multiple functions onto one button. When the object is pressed, multiple functions are executed in sequence one by one to meet the requirements of the user. 399 399 400 -The combination switch contains sub-functions such as bit operation, word operation, arithmetic and screen change. Click the corresponding button on the "General" of the object to add sub-functions to the list, and up to 100 sub-functions can be added. 401 - 402 402 (% class="box infomessage" %) 403 403 ((( 404 -✎**Note:** there can only be one screen change function in the added sub-functions, and it is at the end of the list).391 +✎**Note:** There can only be one screen change function in the added sub-functions, and it is at the end of the list). 405 405 ))) 406 406 407 407 **Description** ... ... @@ -486,9 +486,9 @@ 486 486 * For [[text>>https://docs.we-con.com.cn/bin/view/PIStudio/7.Library/#HText]]/[[graphics>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HGraphic]]/[[security>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HSecurity]]/[[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>path:https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 487 487 ))) 488 488 489 -== Slide rswitch ==476 +== Slide switch == 490 490 491 - Slide switch is a special switch object.By changing the position of the slider, the corresponding address value would be changed. At the same time, the slider position will change according to the address value.478 +By changing the position of the slider, the corresponding address value would be changed. At the same time, the slider position will change according to the address value. 492 492 493 493 (% style="text-align:center" %) 494 494 [[image:6.Objects_html_cc27b49cc3421a77.gif||class="img-thumbnail"]] ... ... @@ -561,7 +561,7 @@ 561 561 562 562 == Numeric Input/Display == 563 563 564 -"Numeric Input/Display" displays the device's data or writes data to the device in a specified numeric format , and the data could be scaled.551 +"Numeric Input/Display" displays the device's data or writes data to the device in a specified numeric format. 565 565 566 566 (% style="text-align:center" %) 567 567 [[image:6-1NumericInput.png||class="img-thumbnail"]] ... ... @@ -579,7 +579,7 @@ 579 579 **✎Note: **Check it to use the comment information on the keyboard. When the user clicks on the part, the comment information will be written into the HUW1402 for display. The maximum length allowed for the comment is 63 characters; 580 580 ))) 581 581 582 -* **Continuous Input: ** Use the samekeyboardtoinputtheobjectsfromthe same Group NOaccordingtotheorderof NO, and automaticallyclosethe keyboard after thelastNO(object) is input;569 +* **Continuous Input: **Numeric input objects with the same Group NO can be entered continuously using the same keyboard according to the NO order; 583 583 * **NO: **the number of numeric input object; 584 584 * **Group NO: **the group number of numeric input object; 585 585 ... ... @@ -611,7 +611,7 @@ 611 611 612 612 **Keypad position** 613 613 614 - It is usedforsettingkeypadposition wheninput data.601 +The pop-up position of keypad screen. 615 615 616 616 **Label** 617 617 ... ... @@ -627,7 +627,7 @@ 627 627 628 628 == Character Input/Display == 629 629 630 -" Numeric Input/Display" displays the device's character or writes character to the device.617 +"Character Input/Display" displays the device's character or writes character to the device. 631 631 632 632 **Description** 633 633 ... ... @@ -639,15 +639,10 @@ 639 639 * **Read Address:** The data from designated address will be displayed. 640 640 * **Input: **Enable input function and "Write Address" configuration. 641 641 * **Same read-write address:** Configure "Write Address" is the same as "Read Address". 642 -* **Read DWord: **Read address is2wordsformat629 +* **Read DWord: **Read the address data at double byte format. 643 643 * **Write address: **Write data to designated address. The address could be different "Read Address". 644 -* **Keypad:** it is standard numeric keypad, allow to input decimal and floating; 645 - 646 -(% class="box infomessage" %) 647 -((( 648 -**✎Note:** ** **Check it to use the comment information on the keyboard. When the user clicks on the part, the comment information will be written into the HUW1402 for display. The maximum length allowed for the comment is 63 characters; 649 -))) 650 - 631 +* **Keypad:** Built-in character keyboard input(Screen No.1001) could allow input a~~z, A~~Z, 0~~9. 632 +* **Note**: After the keypad is opened, the content of note will be input into special register HUW1402. The maximum length allowed for the note is 63 characters. 651 651 * **Continuous Input: **Use the same keyboard to input the objects from the same Group NO according to the order of NO, and automatically close the keyboard after the last NO (object) is input. 652 652 * **NO: **the number of numeric input object. 653 653 * **Group NO: **the group number of numeric input object. ... ... @@ -664,9 +664,9 @@ 664 664 * **Center:** data display on the center of object. 665 665 * **Align left: **data display on the left. 666 666 * **Align right: **data display on the right. 667 -* **Exchange high-low byte: ** ExchangeHigh-lowbyte:Checkit to exchangeanddisplaythecontentsofthehigh andlow bytes.numberof contents is not a multiple of 2, therounding processwillbeperformed.649 +* **Exchange high-low byte: **Swap the contents of high byte and low byte then display. High byte data into low byte position, low byte data into high byte position. If the length of characters is not a multiple of 2, it will exchange after rounded. 668 668 * **Length: **The length of characters, the maximum length is 256. 669 -* **Exchange high-low word: ** Check it to exchange and displaythe contents of high and low word. Only validifthenumberofoperatingcharactersof the partis a multiple of 4.651 +* **Exchange high-low word: **Swap the contents of high word and low word then display. Only valid when the length of characters is a multiple of 4. 670 670 671 671 **Keypad position** 672 672 ... ... @@ -1428,7 +1428,7 @@ 1428 1428 1429 1429 == **Pointer meter** == 1430 1430 1431 -Th emeterresponds to changeinthevalue of theindicatedword address by means of a dial and a pointer.The meter looks very similarto the actual meter.1413 +This object shows the numerical change of the word address by meter format. 1432 1432 1433 1433 (% style="text-align:center" %) 1434 1434 [[image:image-20220805161001-1.jpeg]] ... ... @@ -1506,7 +1506,7 @@ 1506 1506 1507 1507 **(3) Alarm settings** 1508 1508 1509 - It provides alarmfunctioninmeter,userscouldsetalarmrange,userscouldsetthe4 ranges. And each rangecorrespondsto a different alarmcolor.1491 +Alarm setting can be configured to display different colors, with each color corresponding to a different range. There are a maximum of four alert ranges. 1510 1510 1511 1511 **(4) Show scale** 1512 1512 ... ... @@ -2258,6 +2258,15 @@ 2258 2258 [[image:企业微信截图_1673081156755.png]] 2259 2259 2260 2260 (% class="wikigeneratedid" %) 2243 +**EZVIZ Camera Parameters Comparison for HMI Series** 2244 + 2245 +|=(% style="width: 190px;" %)HMI Series|=(% style="width: 240px;" %)System Version|=(% style="width: 284px;" %)Number of Cameras Supported|=(% style="width: 245px;" %)Actual Screen Support Display Camera or not|=(% style="width: 240px;" %)V-NET Display|=(% style="width: 223px;" %)V-NET APP Display 2246 +|=(% style="width: 190px;" %)8000 Series|(% style="width:240px" %)HMI V2.0|(% style="width:284px" %)1|(% style="width:245px" %)Yes|(% style="width:240px" %)Yes|(% style="width:223px" %)Yes 2247 +|=(% style="width: 190px;" %)9000 Series|(% style="width:240px" %)HMI V2.0|(% style="width:284px" %)4|(% style="width:245px" %)Yes|(% style="width:240px" %)Yes|(% style="width:223px" %)Yes 2248 +|=(% style="width: 190px;" %)3000ig Series|(% style="width:240px" %)HMI V2.0|(% style="width:284px" %)1|(% style="width:245px" %)No|(% style="width:240px" %)Yes|(% style="width:223px" %)Yes 2249 +|=(% style="width: 190px;" %)8000ig Series|(% style="width:240px" %)HMI V2.0|(% style="width:284px" %)4|(% style="width:245px" %)Yes|(% style="width:240px" %)Yes|(% style="width:223px" %)Yes 2250 + 2251 +(% class="wikigeneratedid" %) 2261 2261 The function address will occupy the 125 word address, the following table is using the HDW6000 as a example: 2262 2262 2263 2263 (% style="width:892px" %)