Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -230,21 +230,20 @@ 230 230 231 231 **Edit** 232 232 233 -* **Read address: **Read value from specified address. 233 +* **Read address: **Read value from object display. 234 +* **Same read-write address**: Enable it if want to the read address and write address is exactly same. 234 234 * **Write address: **Write value to specified address. 235 235 236 -Read and write address could be the same; 237 - 238 238 **Data format** 239 239 240 -* **Format**: It is for settingoperatingdata format;itcouldsupport sevenmodes.239 +* **Format**: Set the data format: 16bit BCD, 16bit Unsigned, 16bit Signed, 32bit BCD, 32bit Unsigned, 32bit Signed, 32bit Float. 241 241 242 -**Mode** . It is for setting operating mode for value, it could support 3 modes.241 +**Mode** 243 243 244 244 * **Set value: **Set a constant value for the word address. 245 -* **Increase: **Increase the [operand]value for each time the switch is triggered.246 -* **Decrease:** Decrease the [operand]value for each time the switch is triggered.247 -* **High/Low limit:** The value will not increase/decrease when the value reaches limits.244 +* **Increase: **Increase Operand value for each time the switch is triggered. 245 +* **Decrease:** Decrease Operand value for each time the switch is triggered. 246 +* **High/Low limit:** The value will be not able to change when the value reaches limits. 248 248 249 249 (% class="box infomessage" %) 250 250 ((( ... ... @@ -265,53 +265,45 @@ 265 265 266 266 **Address** 267 267 268 -* **Read address:** read the value from specified address. 267 +* **Read address:** Read the value from object display. 268 +* **States count: **Total status number for current word address, which could change the state value according to different status in button [State values], range: 1-256. 269 +* **State with value out of range**: When the value of the read address is not on the range of states' value, it will cause no corresponding status number is displayed. There are two modes for process when the value is out of range. 270 +* **Hide**: Hide the object when the value is out of range; 271 +* **Show state**: Specify a status when the value is out of range, for example the total states is 6(range from state No.0~~No.5), but the read value is 6, at this moment the object will show the state No.0 if selected item of show state is No.0; 269 269 270 -**States settings** 271 - 272 -* **States count: **The default Word state displays the number of States 1, which could be selected by the drop-down list to display the state of object, range: 1-256. 273 -* **State value: **Users could set different values to correspond to different states, the setting window as below figure shows. 274 - 275 275 **For example** 276 276 277 - Bydefault,whenvalueof read address is0, objectdisplaysstate0.275 +The state No.0 default fill value 0, No.1 default fill value 1... and so on. 278 278 279 279 If change settings as below figure shows 280 280 281 -When value of read address is 11, object displays state 1. 279 +When value of read address is 11, object displays state No.1. 282 282 283 283 (% style="text-align:center" %) 284 284 [[image:6.Objects_html_da9a6696f320b427.gif||class="img-thumbnail"]] 285 285 286 -**State of value out of range: **When the value of read address exceeds the maximum state number, there is no corresponding state to be displayed. So there are two modes of processing for it: "Hide" and "Show state" 287 - 288 -**Hide: **When the value of the read address exceeds the set range value, the word state display object will be blank. 289 - 290 -**Show state: **When the value of the read address exceeds the set range value, the object will display the "Specified state". For example, set the maximum is state 7 (value is 6), when the read address of the value is greater than 6, it will display state 2 text and pictures. 291 - 292 292 **Transform state** 293 293 294 -* **Quick Read: ** Directly read thevalueoftheconnecteddevice without goingthroughtheHMIcache286 +* **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 295 295 * **Auto transforms:** Object switch states automatically 296 296 297 297 (% style="text-align:center" %) 298 298 [[image:6.Objects_html_b643c9a6a4bd6919.gif||class="img-thumbnail"]] 299 299 300 -**Trigger:**Control bit to enable switch automatically 292 +* **Trigger to transform: **Trigger condition of auto transform 293 +* **Auto return:** Return to the initial state after reaching the final state; 294 +* **Time of transform:** Set the interval of transform between two states; 295 +* **Dynamic interval: **Set the dynamic interval of transform between two states. If the value in address is 10, then the frequency of automatic switching state is 10*100ms = 1s. 301 301 302 -* **Auto return:** return to the initial state after reaching the final state; 303 -* **Time of transform:** it is used for setting the frequency in automatic switching state. Unit: 100ms. 304 -* **Dynamic interval: **set the frequency of automatic switching state and read it from the address. Unit: 100ms. If the value in address is 10, then the frequency of automatic switching state is 10*100ms = 1s. 305 - 306 306 **Manual** 307 307 308 308 (% style="text-align:center" %) 309 309 [[image:6.Objects_html_a8b6636bd862369c.gif||class="img-thumbnail"]] 310 310 311 -* **Set state: **Set a constant value for thewordaddress.312 -* **State increase: **Increase stateforeach time the switchisriggered.313 -* **State decrease:** Decrease stateforeachtime theswitchistriggered.314 -* **Last state:** statewillnot increase/decreasewhen reaches limits.302 +* **Set state: **Set a constant value to address(according to the operate state selection) when click the object. 303 +* **State increase: **Increase the address value by one step when click the object, the upper limit is depends on the Last state selection. 304 +* **State decrease:** Decrease the address value by one step when click the object, the lower limit is depends on the Last state selection.. 305 +* **Last state: **The upper limit or lower limit(Final state) of state increase/decrease; 315 315 316 316 (% class="box infomessage" %) 317 317 ((( ... ... @@ -318,9 +318,9 @@ 318 318 ✎**Note:** For [[text>>https://docs.we-con.com.cn/bin/view/PIStudio/7.Library/#HText]]/[[graphics>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HGraphic]]/[[security>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HSecurity]]/[[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>path:https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 319 319 ))) 320 320 321 -== Keypad switch==312 +== Button == 322 322 323 - Keypad switchis designed to input datamanually;this object need to work with theKeypad.User could assign letters or numbers for eachswitch, when the switch is triggered the data will inputthe textbox.314 +Button is designed to input data into the corresponding inputbox, this object need to work with the numeric input and character input. User could assign letters or numbers for each button. 324 324 325 325 **Description** 326 326 ... ... @@ -338,7 +338,7 @@ 338 338 339 339 == Function switch == 340 340 341 -Function switch is designed to switch screens, and call and close sub screen, and transfer datarecord files.332 +Function switch is designed to switch screens, and call and close sub screen, and transfer record files. 342 342 343 343 **Description** 344 344 ... ... @@ -345,8 +345,6 @@ 345 345 (% style="text-align:center" %) 346 346 [[image:6.Objects_html_31c4ad387507a16d.gif||class="img-thumbnail"]] 347 347 348 -**Operation** 349 - 350 350 * **Screen No: **Switch to the selected screen, it could not be subscreen; 351 351 * **Open sub screen: **Pop-up selected sub screen, and set sub screen position, default position is (0, 0), this is the coordinates of the top left corner of the screen; 352 352 ... ... @@ -375,7 +375,7 @@ 375 375 376 376 **Using trigger address**. As the figure above, when 00 is ON, then selected operation of the function switch will be executed. 377 377 378 -**All terminals effect** .When this function is enabled, all terminals (screens, mobile phones, ipads, computers, etc.) will execute the function Switch Function simultaneously. For example, the screens of each terminal are different. When the screen is clicked to jump to the "Home" screen, all terminals will jump to the home screen.367 +**All terminals effect**: When this function is enabled, all terminals (screens, mobile phones, ipads, computers, etc.) will execute the function Switch Function simultaneously. For example, the screens of each terminal are different. When the screen is clicked to jump to the "Home" screen, all terminals will jump to the home screen. 379 379 380 380 (% class="box infomessage" %) 381 381 (((