Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -230,20 +230,21 @@ 230 230 231 231 **Edit** 232 232 233 -* **Read address: **Read value from object display. 234 -* **Same read-write address**: Enable it if want to the read address and write address is exactly same. 233 +* **Read address: **Read value from specified address. 235 235 * **Write address: **Write value to specified address. 236 236 236 +Read and write address could be the same; 237 + 237 237 **Data format** 238 238 239 -* **Format**: Set the data format:16bitBCD,16bitUnsigned, 16bit Signed, 32bit BCD, 32bit Unsigned,32bit Signed, 32bit Float.240 +* **Format**: It is for setting operating data format; it could support seven modes. 240 240 241 -**Mode** 242 +**Mode**. It is for setting operating mode for value, it could support 3 modes. 242 242 243 243 * **Set value: **Set a constant value for the word address. 244 -* **Increase: **Increase Operand value for each time the switch is triggered.245 -* **Decrease:** Decrease Operand value for each time the switch is triggered.246 -* **High/Low limit:** The value will benot abletochange when the value reaches limits.245 +* **Increase: **Increase the [operand] value for each time the switch is triggered. 246 +* **Decrease:** Decrease the [operand] value for each time the switch is triggered. 247 +* **High/Low limit:** The value will not increase/decrease when the value reaches limits. 247 247 248 248 (% class="box infomessage" %) 249 249 ((( ... ... @@ -264,23 +264,30 @@ 264 264 265 265 **Address** 266 266 267 -* **Read address:** Read the value from object display. 268 -* **States count: **Total status number for current word address, which could change the state value according to different status in button [State values], range: 1-256. 269 -* **State with value out of range**: When the value of the read address is not on the range of states' value, it will cause no corresponding status number is displayed. There are two modes for process when the value is out of range. 270 -* **Hide**: Hide the object when the value is out of range; 271 -* **Show state**: Specify a status when the value is out of range, for example the ; 268 +* **Read address:** read the value from specified address. 272 272 270 +**States settings** 271 + 272 +* **States count: **The default Word state displays the number of States 1, which could be selected by the drop-down list to display the state of object, range: 1-256. 273 +* **State value: **Users could set different values to correspond to different states, the setting window as below figure shows. 274 + 273 273 **For example** 274 274 275 - Thestate No.0defaultfillvalue 0,No.1 defaultfillvalue1... and so on.277 +By default, when value of read address is 0, object displays state 0. 276 276 277 277 If change settings as below figure shows 278 278 279 -When value of read address is 11, object displays state No.1.281 +When value of read address is 11, object displays state 1. 280 280 281 281 (% style="text-align:center" %) 282 282 [[image:6.Objects_html_da9a6696f320b427.gif||class="img-thumbnail"]] 283 283 286 +**State of value out of range: **When the value of read address exceeds the maximum state number, there is no corresponding state to be displayed. So there are two modes of processing for it: "Hide" and "Show state" 287 + 288 +**Hide: **When the value of the read address exceeds the set range value, the word state display object will be blank. 289 + 290 +**Show state: **When the value of the read address exceeds the set range value, the object will display the "Specified state". For example, set the maximum is state 7 (value is 6), when the read address of the value is greater than 6, it will display state 2 text and pictures. 291 + 284 284 **Transform state** 285 285 286 286 * **Quick Read: **Directly read the value of the connected device without going through the HMI cache