Changes for page 05 Objects

Last modified by Jett on 2025/07/04 09:41

From version 88.2
edited by Hunter
on 2024/02/20 10:59
Change comment: There is no comment for this version
To version 91.1
edited by Hunter
on 2024/07/05 19:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -626,9 +626,9 @@
626 626  * **Read Address:** The data from designated address will be displayed.
627 627  * **Input: **Enable input function and "Write Address" configuration.
628 628  * **Same read-write address:** Configure "Write Address" is the same as "Read Address".
629 -* **Read DWord: **Read address is 2 words format
629 +* **Read DWord: **Read the address data at double byte format.
630 630  * **Write address: **Write data to designated address. The address could be different "Read Address".
631 -* **Keypad:** it is standard numeric keypad, allow to input decimal and floating.
631 +* **Keypad:** Built-in character keyboard input(Screen No.1001) could allow input a~~z, A~~Z, 0~~9.
632 632  * **Note**: After the keypad is opened, the content of note will be input into special register HUW1402. The maximum length allowed for the note is 63 characters.
633 633  * **Continuous Input: **Use the same keyboard to input the objects from the same Group NO according to the order of NO, and automatically close the keyboard after the last NO (object) is input.
634 634  * **NO: **the number of numeric input object.
... ... @@ -646,9 +646,9 @@
646 646  * **Center:** data display on the center of object.
647 647  * **Align left: **data display on the left.
648 648  * **Align right: **data display on the right.
649 -* **Exchange high-low byte: **Exchange High-low byte: Check it to exchange and display the contents of the high and low bytes. If the number of contents is not a multiple of 2, the rounding process will be performed.
649 +* **Exchange high-low byte: **Swap the contents of high byte and low byte then display. High byte data into low byte position, low byte data into high byte position. If the length of characters is not a multiple of 2, it will exchange after rounded.
650 650  * **Length: **The length of characters, the maximum length is 256.
651 -* **Exchange high-low word: **Check it to exchange and display the contents of high and low word. Only valid if the number of operating characters of the part is a multiple of 4.
651 +* **Exchange high-low word: **Swap the contents of high word and low word then display. Only valid when the length of characters is a multiple of 4.
652 652  
653 653  **Keypad position**
654 654  
... ... @@ -1410,7 +1410,7 @@
1410 1410  
1411 1411  == **Pointer meter** ==
1412 1412  
1413 -The meter responds to change in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1413 +This object shows the numerical change of the word address by meter format.
1414 1414  
1415 1415  (% style="text-align:center" %)
1416 1416  [[image:image-20220805161001-1.jpeg]]
... ... @@ -1488,7 +1488,7 @@
1488 1488  
1489 1489  **(3) Alarm settings**
1490 1490  
1491 -It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color.
1491 +Alarm setting can be configured to display different colors, with each color corresponding to a different range. There are a maximum of four alert ranges.
1492 1492  
1493 1493  **(4) Show scale**
1494 1494  
... ... @@ -2240,6 +2240,15 @@
2240 2240  [[image:企业微信截图_1673081156755.png]]
2241 2241  
2242 2242  (% class="wikigeneratedid" %)
2243 +**EZVIZ Camera Parameters Comparison for HMI Series**
2244 +
2245 +|=(% style="width: 190px;" %)HMI Series|=(% style="width: 240px;" %)System Version|=(% style="width: 284px;" %)Number of Cameras Supported|=(% style="width: 245px;" %)Actual Screen Support Display Camera or not|=(% style="width: 240px;" %)V-NET Display|=(% style="width: 223px;" %)V-NET APP Display
2246 +|=(% style="width: 190px;" %)8000 Series|(% style="width:240px" %)HMI V2.0|(% style="width:284px" %)1|(% style="width:245px" %)Yes|(% style="width:240px" %)Yes|(% style="width:223px" %)Yes
2247 +|=(% style="width: 190px;" %)9000 Series|(% style="width:240px" %)HMI V2.0|(% style="width:284px" %)4|(% style="width:245px" %)Yes|(% style="width:240px" %)Yes|(% style="width:223px" %)Yes
2248 +|=(% style="width: 190px;" %)3000ig Series|(% style="width:240px" %)HMI V2.0|(% style="width:284px" %)1|(% style="width:245px" %)No|(% style="width:240px" %)Yes|(% style="width:223px" %)Yes
2249 +|=(% style="width: 190px;" %)8000ig Series|(% style="width:240px" %)HMI V2.0|(% style="width:284px" %)4|(% style="width:245px" %)Yes|(% style="width:240px" %)Yes|(% style="width:223px" %)Yes
2250 +
2251 +(% class="wikigeneratedid" %)
2243 2243  The function address will occupy the 125 word address, the following table is using the HDW6000 as a example:
2244 2244  
2245 2245  (% style="width:892px" %)