Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.Stone - Content
-
... ... @@ -1,9 +1,9 @@ 1 1 (% class="wikigeneratedid" id="H8BasicFunction" %) 2 -This chapter provides information about basic functions and config iration in PIStudio.2 +This chapter provides information about basic functions and configuration in PIStudio. 3 3 4 4 = **{{id name="_Toc28532"/}}Alarm** = 5 5 6 -== **Bit Alarm** ==6 +== **Bit alarm** == 7 7 8 8 Click "Project"->"Bit alarm", it is displayed as the following figure. 9 9 ... ... @@ -18,7 +18,7 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud a and it is alarm data. (Only ig supported)21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 22 22 23 23 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 24 24 ... ... @@ -37,7 +37,7 @@ 37 37 38 38 **✎Note:** 39 39 40 -* If the "cloud" function is enabled and "upload to cloud" is checked, the commun nication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally.40 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 41 41 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 42 42 43 43 **Operating Procedures of Adding One Alarm** ... ... @@ -64,7 +64,7 @@ 64 64 65 65 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 66 66 67 -Click "P orject"->"Word alarm", it is displayed as the following figure.67 +Click "Project"->"Word alarm", it is displayed as the following figure. 68 68 69 69 (% style="text-align:center" %) 70 70 [[image:字报警 1.png||class="img-thumbnail"]] ... ... @@ -77,11 +77,11 @@ 77 77 78 78 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 79 79 80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud a and it is alarm data. (Only ig supported)80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 81 81 82 82 **✎Note:** 83 83 84 -* If the "cloud" function is enabled and "upload to cloud" is checked, the commun nication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.84 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 85 85 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 86 86 87 87 **(6) Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. ... ... @@ -119,13 +119,13 @@ 119 119 1. Click "Project"-> "Word Alarm" as below shows. 120 120 121 121 (% style="text-align:center" %) 122 -[[image:8.Basic Function_html_1b59522c984cd7c2.png|| class="img-thumbnail" height="144" width="492"]]122 +[[image:8.Basic Function_html_1b59522c984cd7c2.png||height="144" width="492" class="img-thumbnail"]] 123 123 124 124 (% start="2" %) 125 125 1. Click [Add] button to open [Word Alarm] setting window. 126 126 127 127 (% style="text-align:center" %) 128 -[[image:8.Basic Function_html_942107c81fc6901c.png|| class="img-thumbnail" height="307" width="554"]]128 +[[image:8.Basic Function_html_942107c81fc6901c.png||height="307" width="554" class="img-thumbnail"]] 129 129 130 130 (% start="3" %) 131 131 1. Set Basic information of word alarm. ... ... @@ -150,7 +150,7 @@ 150 150 151 151 The maximum number of group in recipe is 1000, and the maximum number of member in each group is 1500. 152 152 153 -Recipe could store the data in USB flash disk and SD card and view the recipe data by ob ejct "Recipe display". It has two mode: simple mode and advanced mode.153 +Recipe could store the data in USB flash disk and SD card and view the recipe data by object "Recipe display". It has two mode: simple mode and advanced mode. 154 154 155 155 1. **Simple: **Only support the data operation of one recipe file, including read and write. 156 156 1. **Advanced:** Support the data operation of multiple recipe files, including read, write, insert and index. View and select recipe file by object "File list". ... ... @@ -232,12 +232,12 @@ 232 232 1) Click "Project"->"Bit Alarm" as below shows. 233 233 234 234 (% style="text-align:center" %) 235 -[[image:8.Basic Function_html_a7d1546a3a9f752f.png|| class="img-thumbnail" height="144" width="535"]]235 +[[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]] 236 236 237 237 2) Click "Add" button to open "Recipe" setting window. 238 238 239 239 (% style="text-align:center" %) 240 -[[image:8.Basic Function_html_8f04e01413981054.png|| class="img-thumbnail" height="307" width="554"]]240 +[[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]] 241 241 242 242 3) Set basic settings for recipe. 243 243 ... ... @@ -273,9 +273,9 @@ 273 273 274 274 == **Recipe display** == 275 275 276 -Select the file type "Traditional recipe file" in o nject "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.276 +Select the file type "Traditional recipe file" in object "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line. 277 277 278 -**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as foll woing shown:278 +**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as following shown: 279 279 280 280 (% style="text-align:center" %) 281 281 [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]] ... ... @@ -423,7 +423,7 @@ 423 423 1. **Data format: **It is for setting all the curves, select the data format for all curves, and setting the reading addresses for curves. There are as follows. 424 424 425 425 (% style="text-align:center" %) 426 -[[image: http://docs.we-con.com.cn/wiki/pistudio/download/Helps/08.Basic%20Function/WebHome/%E8%B6%8B%E5%8A%BF%E5%9B%BE%E8%AE%BE%E7%BD%AE%203.png?rev=1.1||alt="趋势图设置 3.png" class="img-thumbnail"]]426 +[[image:image-20220616145435-1.png]] 427 427 428 428 (% start="2" %) 429 429 1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. ... ... @@ -437,13 +437,13 @@ 437 437 1. Click "Project" -> "History XY Plot" to open the function selecting windows. 438 438 439 439 (% style="text-align:center" %) 440 -[[image:8.Basic Function_html_5da6ca44bd28acbe.png|| class="img-thumbnail" height="144" width="533"]]440 +[[image:8.Basic Function_html_5da6ca44bd28acbe.png||height="144" width="533" class="img-thumbnail"]] 441 441 442 442 (% start="2" %) 443 443 1. Click "Add" button to open [History XY Plot] setting windows. 444 444 445 445 (% style="text-align:center" %) 446 -[[image:8.Basic Function_html_6345b50ea55168fa.png|| class="img-thumbnail" height="307" width="554"]]446 +[[image:8.Basic Function_html_6345b50ea55168fa.png||height="307" width="554" class="img-thumbnail"]] 447 447 448 448 1. Setting the function of History XY Plot. 449 449 1. Click "OK" to save the setting. ... ... @@ -459,7 +459,7 @@ 459 459 The topology is shown in the following figure. 460 460 461 461 (% style="text-align:center" %) 462 -[[image:8.Basic Function_html_1b4bd09dafa7e049.png|| class="img-thumbnail" height="332" width="554"]]462 +[[image:8.Basic Function_html_1b4bd09dafa7e049.png||height="332" width="554" class="img-thumbnail"]] 463 463 464 464 The data record stored in SD card is also organized according to the above figure. 465 465 ... ... @@ -477,7 +477,7 @@ 477 477 **Settings** 478 478 479 479 (% style="text-align:center" %) 480 -[[image:数据记录设置 1.png|| class="img-thumbnail" height="533" width="848"]]480 +[[image:数据记录设置 1.png||height="533" width="848" class="img-thumbnail"]] 481 481 482 482 **Operating Procedures** 483 483 ... ... @@ -501,7 +501,7 @@ 501 501 * If the total amount exceeds the range, an alarm will be given during project compilation. 502 502 503 503 (% style="text-align:center" %) 504 -[[image:数据记录设置 2.png|| class="img-thumbnail" height="572" width="850"]]504 +[[image:数据记录设置 2.png||height="572" width="850" class="img-thumbnail"]] 505 505 506 506 **(1) Group name:** Set group name, and he name should be unique. 507 507 ... ... @@ -749,7 +749,7 @@ 749 749 [[image:消息提示 2.png||class="img-thumbnail"]] 750 750 751 751 (% style="text-align:center" %) 752 -[[image:8.Basic Function_html_5ce2091d6f7cd732.png|| class="img-thumbnail" height="515" width="704"]]752 +[[image:8.Basic Function_html_5ce2091d6f7cd732.png||height="515" width="704" class="img-thumbnail"]] 753 753 754 754 **(1) Message** 755 755 ... ... @@ -792,7 +792,7 @@ 792 792 Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. 793 793 794 794 (% style="text-align:center" %) 795 -[[image:云配置1.png|| class="img-thumbnail" height="494" width="750"]]795 +[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]] 796 796 797 797 **(1) Enable** 798 798 ... ... @@ -834,7 +834,7 @@ 834 834 Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. 835 835 836 836 (% style="text-align:center" %) 837 -[[image:云配置1.png|| class="img-thumbnail" height="494" width="750"]]837 +[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]] 838 838 839 839 **(1) Enable** 840 840
- image-20220616145435-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Joey - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.6 KB - Content