Changes for page 06 Data Tool

Last modified by Joe on 2025/09/09 10:40

From version 1.1
edited by Wecon
on 2025/09/03 21:03
Change comment: Imported from XAR
To version 6.1
edited by Joe
on 2025/09/08 17:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Wecon
1 +XWiki.joe
Content
... ... @@ -507,6 +507,77 @@
507 507  
508 508  Gray level display: When the object is locked, the text message will be grayed out.
509 509  
510 +== **New recipe function address** ==
511 +
512 +In recipe, new special address is used as Function address.
513 +
514 +**Address Type:** RPG
515 +
516 +(% style="text-align:center" %)
517 +[[image:企业微信截图_17570533194720.png]]
518 +
519 +(% style="text-align:center" %)
520 +[[image:企业微信截图_17570534728083.png]]
521 +
522 +(% class="box infomessage" %)
523 +(((
524 +Note: There is a set of function address in each recipe.
525 +)))
526 +
527 +|(% style="width:107px" %)Name|(% style="width:162px" %)Data format|Length|Function
528 +|(% style="width:107px" %)File name|(% style="width:162px" %)String|15 word address|Input file name
529 +|(% style="width:107px" %)Record select|(% style="width:162px" %)16-bit unsigned decimal|(((
530 +1 word address
531 +
532 +(0-65535)
533 +)))|Currently selected record, numbered starting from 0. When the record selection value changes, the corresponding value will be updated.
534 +|(% style="width:107px" %)Function address|(% style="width:162px" %)16-bit unsigned decimal|(((
535 +1 word address
536 +
537 +(0-65535)
538 +)))|(((
539 +Enter a specific value to send a command to the selected record
540 +
541 +"1": Add a new recipe record
542 +
543 +"2": Delete the selected recipe record
544 +
545 +"3": Upload the recipe
546 +
547 +"4": Download the recipe
548 +
549 +"5": Update the selected recipe record
550 +)))
551 +|(% style="width:107px" %)Result|(% style="width:162px" %)16-bit unsigned decimal|1 word address (-32768~-~-32767)|(((
552 +View the result of executing the command.
553 +
554 +Display "1": Successfully executed the command
555 +
556 +Display "2": The record limit has been reached and no new records can be added.
557 +
558 +Display "4": No corresponding option
559 +
560 +Display "8": unknown command
561 +
562 +Display "16": recipe download failed.
563 +
564 +Display "32": recipe upload failed.
565 +
566 +Display "64": recipe update failed.
567 +)))
568 +|(% style="width:107px" %)Record count|(% style="width:162px" %)16-bit unsigned decimal|(((
569 +1 word address
570 +
571 +(0-65535)
572 +)))|Display the number of records in the current recipe
573 +|(% style="width:107px" %)Element address|(% style="width:162px" %)16-bit unsigned decimal|(((
574 +1 word address
575 +
576 +(0-65535)
577 +)))|Element address
578 +
579 +
580 +
510 510  = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) =
511 511  
512 512  Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.
... ... @@ -827,6 +827,8 @@
827 827  
828 828  You could click here to jump to object "[[Data Record Display>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]"
829 829  
901 += Column Chart =
902 +
830 830  = **User permission** =
831 831  
832 832  **Introduction**
... ... @@ -1271,8 +1271,8 @@
1271 1271  |3000ig
1272 1272  |8000ig
1273 1273  
1274 -
1275 1275  
1348 +
1276 1276  **MQTT Configuration (Common Settings/AWS IOT Settings/ALi Settings/Huawei Settings)**
1277 1277  
1278 1278  This chapter explains how to use configurable type MQTT. Users can publish message to the MQTT server or subscribe topics from the MQTT server.
企业微信截图_17570533194720.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +237.6 KB
Content
企业微信截图_17570534728083.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +192.8 KB
Content