Changes for page 06 Data Tool

Last modified by Joe on 2025/09/09 10:40

From version 1.1
edited by Wecon
on 2025/09/03 21:03
Change comment: Imported from XAR
To version 8.1
edited by Joe
on 2025/09/08 17:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Wecon
1 +XWiki.joe
Content
... ... @@ -507,6 +507,77 @@
507 507  
508 508  Gray level display: When the object is locked, the text message will be grayed out.
509 509  
510 +== **New recipe function address** ==
511 +
512 +In recipe, new special address is used as Function address.
513 +
514 +**Address Type:** RPG
515 +
516 +(% style="text-align:center" %)
517 +[[image:企业微信截图_17570533194720.png]]
518 +
519 +(% style="text-align:center" %)
520 +[[image:企业微信截图_17570534728083.png]]
521 +
522 +(% class="box infomessage" %)
523 +(((
524 +Note: There is a set of function address in each recipe.
525 +)))
526 +
527 +|(% style="width:107px" %)Name|(% style="width:162px" %)Data format|Length|Function
528 +|(% style="width:107px" %)File name|(% style="width:162px" %)String|15 word address|Input file name
529 +|(% style="width:107px" %)Record select|(% style="width:162px" %)16-bit unsigned decimal|(((
530 +1 word address
531 +
532 +(0-65535)
533 +)))|Currently selected record, numbered starting from 0. When the record selection value changes, the corresponding value will be updated.
534 +|(% style="width:107px" %)Function address|(% style="width:162px" %)16-bit unsigned decimal|(((
535 +1 word address
536 +
537 +(0-65535)
538 +)))|(((
539 +Enter a specific value to send a command to the selected record
540 +
541 +"1": Add a new recipe record
542 +
543 +"2": Delete the selected recipe record
544 +
545 +"3": Upload the recipe
546 +
547 +"4": Download the recipe
548 +
549 +"5": Update the selected recipe record
550 +)))
551 +|(% style="width:107px" %)Result|(% style="width:162px" %)16-bit unsigned decimal|1 word address (-32768~-~-32767)|(((
552 +View the result of executing the command.
553 +
554 +Display "1": Successfully executed the command
555 +
556 +Display "2": The record limit has been reached and no new records can be added.
557 +
558 +Display "4": No corresponding option
559 +
560 +Display "8": unknown command
561 +
562 +Display "16": recipe download failed.
563 +
564 +Display "32": recipe upload failed.
565 +
566 +Display "64": recipe update failed.
567 +)))
568 +|(% style="width:107px" %)Record count|(% style="width:162px" %)16-bit unsigned decimal|(((
569 +1 word address
570 +
571 +(0-65535)
572 +)))|Display the number of records in the current recipe
573 +|(% style="width:107px" %)Element address|(% style="width:162px" %)16-bit unsigned decimal|(((
574 +1 word address
575 +
576 +(0-65535)
577 +)))|Element address
578 +
579 +
580 +
510 510  = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) =
511 511  
512 512  Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.
... ... @@ -827,6 +827,86 @@
827 827  
828 828  You could click here to jump to object "[[Data Record Display>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]"
829 829  
901 += Column Chart =
902 +
903 +Use the bar chart  to monitor and visualize register data in real time
904 +
905 +== **Y-axis configuration** ==
906 +
907 +Configure the Y-axis parameters, including  value type, minimum ,maximum ,data types, and decimal point settings.
908 +
909 +(% style="text-align:center" %)
910 +[[image:Screenshot 2025-09-08 172930.png]]
911 +
912 +== **Channel setting** ==
913 +
914 +Set the channel address to be displayed.
915 +
916 +**Dynamic color:** Change value of a word address to change the color of the channel display.
917 +
918 +Dynamic color sequence: The color sequence number bound to the channel (click to enter the color sequence configuration interface)
919 +
920 +(% style="text-align:center" %)
921 +[[image:1.png]]
922 +
923 +(% class="wikigeneratedid" %)
924 +**Color sequence configuration interface**
925 +
926 +
927 +**Upgrade to Global Configuration: **This color sequence is upgraded to the global default.
928 +
929 +**Global Configuration:** When a new bar chart control is created in a project, the color sequence has a default configuration. When you upgrade an existing configuration to a global configuration, the default color sequence for the new control will be the same as the configured color sequence.
930 +
931 +(% style="text-align:center" %)
932 +[[image:2.png]]
933 +
934 +
935 +**Enable Baseline:** Set baselines on the bar chart.
936 +
937 +**Baseline: **The baseline ID bound to the channel) (click to enter the baseline configuration interface).
938 +
939 +(% style="text-align:center" %)
940 +[[image:121.png]]
941 +
942 +**Baseline Configuration:**
943 +
944 +**Value type: **Baseline value type
945 +
946 +(**Fixed value: **baseline value is fixedly set; **Dynamic address:** baseline value is read from address).
947 +
948 +**Upgrade to Global Configuration:** This will make this warning zone the global default configuration.
949 +
950 +Global Configuration: When a new bar chart control is created in a project, the warning zone has a default configuration. When you upgrade an existing configuration to a global configuration, the default configuration for the new control will be the same as the configured one.
951 +
952 +(% style="text-align:center" %)
953 +[[image:3.png]]
954 +
955 +== **Appearance setting** ==
956 +
957 +(% class="wikigeneratedid" %)
958 +Set a configuration for the X-axis, background color, etc.
959 +
960 +(% style="text-align:center" %)
961 +[[image:4.png]]
962 +
963 +== **Function settings** ==
964 +
965 +
966 +**Column Update Method:**
967 +
968 +**Periodic Update:** Updates the histogram periodically.
969 +
970 +**Triggered Update: **Controls whether the histogram updates based on an address.
971 +
972 +**Triggered Periodic Update:** Triggers a periodic update of the histogram.
973 +
974 +**Cycle update time: **Periodic update time setting, unit: seconds
975 +
976 +**Function control starting address: **The function of the bar chart can be controlled by the address. The starting address is configured here. For specific functions, refer to the address description list.
977 +
978 +(% style="text-align:center" %)
979 +[[image:0.png]]
980 +
830 830  = **User permission** =
831 831  
832 832  **Introduction**
... ... @@ -1271,8 +1271,8 @@
1271 1271  |3000ig
1272 1272  |8000ig
1273 1273  
1274 -
1275 1275  
1426 +
1276 1276  **MQTT Configuration (Common Settings/AWS IOT Settings/ALi Settings/Huawei Settings)**
1277 1277  
1278 1278  This chapter explains how to use configurable type MQTT. Users can publish message to the MQTT server or subscribe topics from the MQTT server.
1.png
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Wecon
1 +XWiki.joe
Size
... ... @@ -1,1 +1,1 @@
1 -476 bytes
1 +24.9 KB
Content
2.png
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Wecon
1 +XWiki.joe
Size
... ... @@ -1,1 +1,1 @@
1 -419 bytes
1 +6.5 KB
Content
3.png
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Wecon
1 +XWiki.joe
Size
... ... @@ -1,1 +1,1 @@
1 -13.4 KB
1 +15.1 KB
Content
4.png
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Wecon
1 +XWiki.joe
Size
... ... @@ -1,1 +1,1 @@
1 -26.6 KB
1 +34.5 KB
Content
0.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +32.6 KB
Content
121.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +31.2 KB
Content
Screenshot 2025-09-08 172930.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +17.7 KB
Content
企业微信截图_17570533194720.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +237.6 KB
Content
企业微信截图_17570534728083.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +192.8 KB
Content