Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,9 +3,9 @@ 3 3 4 4 = **Alarm** = 5 5 6 -== **Bit alarm** ==6 +== **Bit Alarm** == 7 7 8 -Click "Project"->"Bit alarm", it is displayed as the following figure.8 +Click "Project"->"Bit Alarm", it is displayed as the following figure. 9 9 10 10 (% style="text-align:center" %) 11 11 [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] ... ... @@ -18,8 +18,20 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series after system upgrade are supported) 21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 22 22 23 +**✎Note:** 24 + 25 +* After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 26 +* The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 27 + 28 +(% style="margin-left:auto; margin-right:auto; width:358px" %) 29 +|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 30 +|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 31 +|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 32 +|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 33 +|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 34 + 23 23 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 24 24 25 25 **(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. ... ... @@ -77,7 +77,7 @@ 77 77 78 78 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 79 79 80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 92 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 81 81 82 82 **✎Note:** 83 83 ... ... @@ -84,6 +84,13 @@ 84 84 * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 85 85 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 86 86 99 +(% style="margin-left:auto; margin-right:auto; width:358px" %) 100 +|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 101 +|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 102 +|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 103 +|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 104 +|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 105 + 87 87 **(6) Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. 88 88 89 89 **(7) Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. ... ... @@ -471,8 +471,17 @@ 471 471 472 472 For the file storage of data, see the file size configuration during data record configuration. 473 473 474 -✎**Note: ** The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.493 +✎**Note: ** 475 475 495 +1) 496 + 497 +2) 498 + 499 +3) The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters. 500 + 501 +4) Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ". 502 + 503 + 476 476 (% class="wikigeneratedid" id="HSettings" %) 477 477 **Settings** 478 478