Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PIStudio. 1 User Manual.WebHome1 +PIStudio.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -3,38 +3,49 @@ 3 3 4 4 = **Alarm** = 5 5 6 -== **BitAlarm**==6 +== Bit alarm == 7 7 8 -Click "Project" ->"Bit Alarm", it is displayed as the following figure.8 +Click "Project"→"Bit Alarm", it is displayed as the following figure. 9 9 10 10 (% style="text-align:center" %) 11 11 [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] 12 12 13 -** (1)Group No.: **Group number of Bit alarm. The name is unique and cannot be duplicated.13 +**Group No.: **Group number of Bit alarm. The name is unique and cannot be duplicated. 14 14 15 -** (2)Bit Address: **Bit address of alarm monitoring15 +**Bit Address: **Bit address of alarm monitoring 16 16 17 -(% start="1" %) 18 -1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 -1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 17 +* **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 18 +* **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -** (3)Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)20 +**Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 22 22 23 -** (4) Alarm Condition:**It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.22 +**✎Note:** 24 24 25 -**(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. 24 +* After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 25 +* The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 26 26 27 -**(6) Beep when alarm ON: **The beep works when the alarm is triggered. If "beep once" is checked, bit address alarm only beep once and stop. 27 +(% style="margin-left:auto; margin-right:auto; width:358px" %) 28 +|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 29 +|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 30 +|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 31 +|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 32 +|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 28 28 29 -** (7)Content:isusedforsettingalarmcontent(command).34 +**Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 30 30 31 -** (8)AlarmScreen:**Pop-upalarmscreen(itneedtobe sub-screen);36 +**Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. 32 32 33 -1. **Position: **The location of the screen alarm display. 34 -1. **Pop-up Interval: **The time of reopen the alarm screen when alarm screen closed. 35 -1. **Pop-up once: **Pop up alarm screen once, and the screen would not pop up again 36 -1. **Close window when alarm off: **Automatically close the alarm screen when alarm off. 38 +**Beep when alarm ON: **The beep works when the alarm is triggered. If "beep once" is checked, bit address alarm only beep once and stop. 37 37 40 +**Content: **It is used for setting alarm content (command). 41 + 42 +**Alarm Screen: **Pop-up alarm screen (it need to be sub-screen); 43 + 44 +* **Position: **The location of the screen alarm display. 45 +* **Pop-up Interval: **The time of reopen the alarm screen when alarm screen closed. 46 +* **Pop-up once: **Pop up alarm screen once, and the screen would not pop up again 47 +* **Close window when alarm off: **Automatically close the alarm screen when alarm off. 48 + 38 38 **✎Note:** 39 39 40 40 * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally. ... ... @@ -42,42 +42,40 @@ 42 42 43 43 **Operating Procedures of Adding One Alarm** 44 44 45 - 1.Click "Project"->"Bit Alarm" as below shows.56 +* Click "Project"→"Bit Alarm" as below shows. 46 46 47 47 (% style="text-align:center" %) 48 48 [[image:8.Basic Function_html_5f8da20315334bac.png||data-xwiki-image-style-alignment="center" height="144" width="539" class="img-thumbnail"]] 49 49 50 -(% start="2" %) 51 -1. Click "Add" button to open "Bit Alarm" setting window. 61 +* Click "Add" button to open "Bit Alarm" setting window. 52 52 53 53 (% style="text-align:center" %) 54 54 [[image:8.Basic Function_html_94a019683b506e15.png||data-xwiki-image-style-alignment="center" height="307" width="554" class="img-thumbnail"]] 55 55 56 -(% start="3" %) 57 -1. Set "Bit Address". 58 -1. Set "Alarm Condition". 59 -1. Set "Content". 60 -1. Other settings can be set according to the actual situation". 61 -1. Click "OK" button to complete settings. 66 +* Set "Bit Address". 67 +* Set "Alarm Condition". 68 +* Set "Content". 69 +* Other settings can be set according to the actual situation". 70 +* Click "OK" button to complete settings. 62 62 63 -== **WordAlarm**==72 +== Word alarm == 64 64 65 65 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 66 66 67 -Click "Project" ->"Word alarm", it is displayed as the following figure.76 +Click "Project"→"Word alarm", it is displayed as the following figure. 68 68 69 69 (% style="text-align:center" %) 70 70 [[image:字报警 1.png||class="img-thumbnail"]] 71 71 72 -** (1)Alarm Name:** You can set alarm name for it. Alarm Name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters.81 +**Alarm Name:** You can set alarm name for it. Alarm Name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters. 73 73 74 -** (2)Alarm Address: **It is used for setting word address for word alarm, such as HDW0.83 +**Alarm Address: **It is used for setting word address for word alarm, such as HDW0. 75 75 76 -** (3)Data Format: **16-bit unsigned decimal, 16-bit signed decimal, 16-bit BCD, 32-bit unsigned decimal, 32-bit signed decimal, 32-bit BCD, 32-bit float.85 +**Data Format: **16-bit unsigned decimal, 16-bit signed decimal, 16-bit BCD, 32-bit unsigned decimal, 32-bit signed decimal, 32-bit BCD, 32-bit float. 77 77 78 -** (4)Group No.: **Group number of word alarm. The name is unique and cannot be duplicated.87 +**Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 79 79 80 -** (5)Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. ((Only ig series and 8000/9000 series with -R after system upgrade are supported))89 +**Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 81 81 82 82 **✎Note:** 83 83 ... ... @@ -84,22 +84,29 @@ 84 84 * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 85 85 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 86 86 87 -**(6) Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. 96 +(% style="margin-left:auto; margin-right:auto; width:358px" %) 97 +|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 98 +|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 99 +|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 100 +|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 101 +|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 88 88 89 -** (7) Notsave alarmOFF:**If checked,after the alarm is dismissed,thecorrespondingalarmrecordswill be deletedfromthe log file.103 +**Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. 90 90 91 -** (8)AlarmCondition**:Alarmis triggeredwhendesignatedaddressmeets the alarm condition,itprovidesfourconditions;105 +**Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 92 92 107 +**Alarm Condition**: Alarm is triggered when designated address meets the alarm condition, it provides four conditions; 108 + 93 93 1. **High alarm:** Alarm is triggered when it reaches high limit. It can be a constant or a variable 94 94 1. **Low alarm:** Alarm is triggered when it reaches low limit. It can be a constant or a variable 95 95 1. **Range alarm:** Alarm is triggered when it exceeds the range. It can be a constant or a variable 96 96 1. **Equivalent alarm: **Alarm is triggered when the value equals to the given data. It can be a constant or a variable 97 97 98 -** (9)Alarm Info: **It is used for setting alarm content (command);114 +**Alarm Info: **It is used for setting alarm content (command); 99 99 100 -** (10)Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.116 +**Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. 101 101 102 -** (11)Alarm Screen: **Pop-up alarm screen (it need to be sub-screen);118 +**Alarm Screen: **Pop-up alarm screen (it need to be sub-screen); 103 103 104 104 1. **Position: **The location of the screen alarm display. 105 105 1. **Pop-up Interval: **The time of reopen the alarm screen when alarm screen closed. ... ... @@ -106,38 +106,36 @@ 106 106 1. **Pop-up once: **Pop up alarm screen once. 107 107 1. **Close window when alarm off: **Automatically close the alarm screen when alarm off. 108 108 109 -** (12)Beep when alarm ON: **beep works when the alarm is triggered, in the default mode, the beep works until the alarm is released.125 +**Beep when alarm ON: **beep works when the alarm is triggered, in the default mode, the beep works until the alarm is released. 110 110 111 -** (13)Beep once:** Beep works once, when alarm is triggered.127 +**Beep once:** Beep works once, when alarm is triggered. 112 112 113 -** (14)Alarm List**129 +**Alarm List** 114 114 115 115 It displays all the word alarm lists; it will show the alarm information; 116 116 117 117 **Operating Procedures of Adding One Alarm** 118 118 119 - 1.Click "Project"->"Word Alarm" as below shows.135 +* Click "Project"→ "Word Alarm" as below shows. 120 120 121 121 (% style="text-align:center" %) 122 122 [[image:8.Basic Function_html_1b59522c984cd7c2.png||height="144" width="492" class="img-thumbnail"]] 123 123 124 -(% start="2" %) 125 -1. Click [Add] button to open [Word Alarm] setting window. 140 +* Click "AddClick" button to open "Word Alarm" setting window. 126 126 127 127 (% style="text-align:center" %) 128 128 [[image:8.Basic Function_html_942107c81fc6901c.png||height="307" width="554" class="img-thumbnail"]] 129 129 130 -(% start="3" %) 131 -1. Set Basic information of word alarm. 132 -1. Set "Content". 133 -1. Other settings can be set according to the actual situation. 134 -1. Click "OK" button to complete settings. 145 +* Set Basic information of word alarm. 146 +* Set "Content". 147 +* Other settings can be set according to the actual situation. 148 +* Click "OK" button to complete settings. 135 135 136 136 **HMI Alarm Demo Download Link** 137 137 138 138 [[https:~~/~~/drive.google.com/open?id=1Llq03CMISM_1mMIfU308hxFbs4rGdQGP>>url:https://drive.google.com/open?id=1Llq03CMISM_1mMIfU308hxFbs4rGdQGP]] 139 139 140 -= ** {{id name="_Toc17174"/}}{{id name="_Recipe"/}}Recipe** =154 += **Recipe** = 141 141 142 142 Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC. 143 143 ... ... @@ -162,23 +162,20 @@ 162 162 (% style="text-align:center" %) 163 163 [[image:8-1Recipe.png]] 164 164 165 -** (1)Basic**179 +**Basic** 166 166 167 -1. **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object); 181 +* **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object); 182 +** **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters; 183 +* **Group: **It sets the groups' initial number of recipe; 184 +* **Elements:** It sets members' initial number of each group; 185 +* **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form; 186 +* **Decimal: **It sets integer and scale digits; 168 168 169 -* *✎Note:**Recipe Folder namecan only consistf (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters;188 +**Mode Selection** 170 170 171 -(% start="2" %) 172 -1. **Group: **It sets the groups' initial number of recipe; 173 -1. **Elements:** It sets members' initial number of each group; 174 -1. **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form; 175 -1. **Decimal: **It sets integer and scale digits; 176 - 177 -**(2) Mode Selection** 178 - 179 179 Users could select Simple or Advanced mode. 180 180 181 -** (3)Function Address:**192 +**Function Address:** 182 182 183 183 All the operations for recipe is by this address 184 184 ... ... @@ -189,77 +189,83 @@ 189 189 * =8 Delete. 190 190 * =16 Delete and Sequence. 191 191 192 -** (4)Use Multiple File**203 +**Use Multiple File** 193 193 194 194 Check it to use more than one recipe file in HMI, but this option only valid in [Advanced mode]; 195 195 196 -** (5)Select language**207 +**Select language** 197 197 198 198 The text in HMI can be in 8 languages, user can set language in here; 199 199 200 -** (6)Address**211 +**Address** 201 201 202 202 1. **Group:** This address is for selecting group number; 203 203 1. **Start: **This is starting address is for reading and writing in recipe, PIStudio will automatically assigns addresses for each members; 204 204 1. **File(16 words): **This address only available when enable the Use Multiple File. This setting address is for input the recipe file's filename. 205 205 206 -** (7)Use Index**217 +**Use Index** 207 207 208 208 If the value from Group address is changed, Read address will display the new data according to new group number immediately. Relatively, if the data of write address is changed, the corresponding group from table is also changed. 209 209 210 -** (8)Query by Element**221 +**Query by Element** 211 211 212 212 Enable it for querying group by specify element, select a primary key from all the elements, except the group number. This element value from all groups must be unique if want to set as primary key; 213 213 225 +(% class="box infomessage" %) 226 +((( 214 214 **✎Note: **When this option is enabled, Group address will be invalid. 228 +))) 215 215 216 -** (9)Use Independent Write Address**230 +**Use Independent Write Address** 217 217 218 218 To separate Recipe read address and write address. 219 219 220 -** (10)Use Insert**234 +**Use Insert** 221 221 222 222 It inserts data into the specified group, if the specified group already exists, it would not cover the original data, while it will move the original group next one after it. 223 223 224 -** (11)Discontinuous Address**238 +**Discontinuous Address** 225 225 226 226 Whether enable the non-consecutive recipe operation addresses or not. If disabled, the recipe address will recover as the continuous addresses. 227 227 242 +(% class="box infomessage" %) 243 +((( 228 228 **✎Note: **This function only supported in HMI+, i series, ie series, ig series. 245 +))) 229 229 230 230 **Operating Procedures** 231 231 232 - 1)Click "Project"->"Bit Alarm" as below shows.249 +* Click "Project"→"Bit Alarm" as below shows. 233 233 234 234 (% style="text-align:center" %) 235 235 [[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]] 236 236 237 - 2)Click "Add" button to open "Recipe" setting window.254 +* Click "Add" button to open "Recipe" setting window. 238 238 239 239 (% style="text-align:center" %) 240 240 [[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]] 241 241 242 -3) Set basic settings for recipe. 259 +* Set basic settings for recipe. 260 +* Select mode according to actual condition. 261 +* Other settings can be set according to the actual situation. 262 +* Click "OK“ button to complete settings. 243 243 244 -4) Select mode according to actual condition. 245 - 246 -5) Other settings can be set according to the actual situation. 247 - 248 -6) Click [OK] button to complete settings. 249 - 250 250 **Recipe Demo Download Link** 251 251 252 252 [[https:~~/~~/drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]] 253 253 254 -= (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional Recipe**(%%) =268 += (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) = 255 255 256 256 Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC. 257 257 258 258 Traditional recipe function is valid only when the LEVI project is converted to the PI project, and the original project uses the traditional recipe. 259 259 274 +(% class="box infomessage" %) 275 +((( 260 260 **✎Note**: Currently, only HMI+, i series, ie series, and ig series support the traditional recipe. 277 +))) 261 261 262 -== **Simple recipe mode**==279 +== Simple recipe mode == 263 263 264 264 Click the "Traditional Recipe" [[image:8-2TraditionalRecipe.png]] in the "Data tool" bar in the upper side of the software, and the following interface will pop up: 265 265 ... ... @@ -271,16 +271,19 @@ 271 271 * The recipe folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (''). 272 272 * The element name of the recipe cannot include following 5 special characters: " **,** " , " **|** " , " **<** " , " **>** " , " **&** " . 273 273 274 -== **Recipe display**==291 +== Recipe display == 275 275 276 276 Select the file type "Traditional recipe file" in object "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line. 277 277 278 -**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as following shown: 295 +(% class="box infomessage" %) 296 +((( 297 +**✎Note**: The Recipe Display can display up to 50 groups of 100 elements by default, which can be to display out of range by enabled "Address Control". After the "Address Control" is enabled, the display group number can be reached to 100. If want to display more than 100, please adjust the "Start Group" from "Address Control" to index the display group, as following shown: 298 +))) 279 279 280 280 (% style="text-align:center" %) 281 281 [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]] 282 282 283 -== **Recipe transmission address**==303 +== Recipe transmission address == 284 284 285 285 The special addresses used in the Recipe are shown in the following table: 286 286 ... ... @@ -331,26 +331,26 @@ 331 331 1. The RPW register only supports word address access. 332 332 1. It can be known from the coding method of RPW~*~*~#~#~#~# that the range of RPW is from RPW000000-RPW990450, wherein the range of group number is 0-100, and the range of element is 0-450. 333 333 334 -== **Recipe example**==354 +== Recipe example == 335 335 336 336 The recipe index makes the modification and display of recipe data more convenient. Only need to modify and display the data of the recipe file through "Numeric Input/Display" Object and "Word Switch". 337 337 338 - (1)Edit the recipe configuration, create three groups of recipes, 4 elements for per group: Red, green, blue, spraying time, as following shown:358 +Edit the recipe configuration, create three groups of recipes, 4 elements for per group: Red, green, blue, spraying time, as following shown: 339 339 340 340 (% style="text-align:center" %) 341 341 [[image:8-5TraditionalRecipeCaseConfig.png]] 342 342 343 - (2)RPW 0~~3 can display the data of group for the selected line. RPW10000~~10003, RPW20000~~20003, RPW30000~~30003 each address can display the single element. Directly modify the content of the RPW address and then modify the recipe data, as following shown:363 +RPW 0~~3 can display the data of group for the selected line. RPW10000~~10003, RPW20000~~20003, RPW30000~~30003 each address can display the single element. Directly modify the content of the RPW address and then modify the recipe data, as following shown: 344 344 345 345 (% style="text-align:center" %) 346 346 [[image:8-7TraditionalRecipeCaseShowNoOpera.png]] 347 347 348 - (3)After selecting the 2nd group, trigger the download button to download the whole group data to the corresponding element address (For this case, the data will write into HDW0~~3), or trigger the upload button to upload the content of the element address to the specified recipe group.368 +After selecting the 2nd group, trigger the download button to download the whole group data to the corresponding element address (For this case, the data will write into HDW0~~3), or trigger the upload button to upload the content of the element address to the specified recipe group. 349 349 350 350 (% style="text-align:center" %) 351 351 [[image:8-6TraditionalRecipeCaseShow.png]] 352 352 353 -= ** {{id name="_Toc5565"/}}{{id name="_Trend_Chart"/}}TrendChart** =373 += **Trend chart** = 354 354 355 355 Trend chart function is used for displaying the real-time data in HMI as curve graph, which X axis represent as time, Y axis represent as data. 356 356 ... ... @@ -388,17 +388,20 @@ 388 388 389 389 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 390 390 411 +(% class="box infomessage" %) 412 +((( 391 391 **✎Note: **Curve names can only consist of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_') (' '), and other non-English characters. 414 +))) 392 392 393 393 **Trend Chart Demo Download Link** 394 394 395 395 [[https:~~/~~/drive.google.com/open?id=1smnaAvSxOWC0WQK4_uvqHXWn4vUZxGJC>>url:https://drive.google.com/open?id=1smnaAvSxOWC0WQK4_uvqHXWn4vUZxGJC]] 396 396 397 -= ** {{id name="_Toc7121"/}}{{id name="_History_XY_Plot"/}}HistoryXYPlot** =420 += **History XY plot** = 398 398 399 399 Different from TrendChart, uses need to set history XY curve items in project. Please click "Project"-> "History XY Plot" to open the setting screen. 400 400 401 -Recipe function settings will be display in "[[History XY Plot>>path:http://docs.we-con.com.cn/ wiki/pistudio/view/Helps/06.Objects/#HHistoryXYplot]]" object.424 +Recipe function settings will be display in "[[History XY Plot>>path:https://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HHistoryXYplot]]" object. 402 402 403 403 (% style="text-align:center" %) 404 404 [[image:历史XY 2.png||class="img-thumbnail"]] ... ... @@ -430,29 +430,31 @@ 430 430 431 431 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 432 432 456 +(% class="box infomessage" %) 457 +((( 433 433 **✎Note: **Curve names can only consist of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_') (' '), and other non-English characters. 459 +))) 434 434 435 435 **Operating Procedure** 436 436 437 - 1.Click "Project"->"History XY Plot" to open the function selecting windows.463 +* Click "Project" → "History XY Plot" to open the function selecting windows. 438 438 439 439 (% style="text-align:center" %) 440 440 [[image:8.Basic Function_html_5da6ca44bd28acbe.png||height="144" width="533" class="img-thumbnail"]] 441 441 442 -(% start="2" %) 443 -1. Click "Add" button to open [History XY Plot] setting windows. 468 +* Click "Add" button to open "History XY Plot” setting windows. 444 444 445 445 (% style="text-align:center" %) 446 446 [[image:8.Basic Function_html_6345b50ea55168fa.png||height="307" width="554" class="img-thumbnail"]] 447 447 448 - 1.Setting the function of History XY Plot.449 - 1.Click "OK" to save the setting.473 +* Setting the function of History XY Plot. 474 +* Click "OK" to save the setting. 450 450 451 451 **Download Link** 452 452 453 453 [[https:~~/~~/drive.google.com/open?id=1t4_HuRmIJJ-B5ryA2kVMadD9FywKhZ4r>>url:https://drive.google.com/open?id=1t4_HuRmIJJ-B5ryA2kVMadD9FywKhZ4r]] 454 454 455 -= (% style="color:inherit; font-family:inherit; font-size:29px" %)**Data Record**(%%) =480 += (% style="color:inherit; font-family:inherit; font-size:29px" %)**Data record**(%%) = 456 456 457 457 The data record function is organized according to the structure below. In a project, there can be multiple record groups, each record group containing multiple channels. Different groups have different sampling times. 458 458 ... ... @@ -471,8 +471,23 @@ 471 471 472 472 For the file storage of data, see the file size configuration during data record configuration. 473 473 474 -✎**Note: ** The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.499 +✎**Note: ** 475 475 501 +After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Data record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 502 + 503 +The number of Data records upload to Cloud shall not exceed the limit value, or the sum of the imported Data records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 504 + 505 +(% style="margin-left:auto; margin-right:auto; width:513px" %) 506 +|=(% style="width: 70px;" %)Series|=(% style="width: 442px;" %)Number of Data Record upload to Cloud 507 +|(% style="width:70px" %)8000-R|(% style="text-align:center; width:442px" %)100 508 +|(% style="width:70px" %)9000-R|(% style="text-align:center; width:442px" %)100 509 +|(% style="width:70px" %)3000ig|(% style="text-align:center; width:442px" %)50 510 +|(% style="width:70px" %)8000ig|(% style="text-align:center; width:442px" %)100 511 + 512 +The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters. 513 + 514 +Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ". 515 + 476 476 (% class="wikigeneratedid" id="HSettings" %) 477 477 **Settings** 478 478 ... ... @@ -542,17 +542,10 @@ 542 542 * The channel name does not include these 5 special characters: ", ", "| "," <", "> "," & ". 543 543 * The data would be overwritten automatically if the capacity exceed the maximum capacity. For 8000/9000 series, the size of single file cannot exceed 300MB, and total capacity of data records cannot exceed 1000MB. For 3000/3000i/3000ie series, the size of single file cannot exceed 4MB, and total capacity of data records cannot exceed 10MB. If the total amount exceeds the range , an error will be prompted when the project is compiled. 544 544 545 -You could click here to jump to object "[[Data Record Display>>http://docs.we-con.com.cn/ wiki/pistudio/view/Helps/06.Objects/#HDataRecordDisplay]]"585 +You could click here to jump to object "[[Data Record Display>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]" 546 546 547 -(% class="wikigeneratedid" id="H" %) 548 -**PI Data Record Demo Download** 587 += **User permission** = 549 549 550 -**[[Demo Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 551 - 552 -**[[Video Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 553 - 554 -= **{{id name="_Toc3497"/}}{{id name="_User_Permission"/}}User Permission** = 555 - 556 556 **Introduction** 557 557 558 558 1. User permission is one of expansion function in PI Series HMI; it provides multi-level of permission for control HMI operations. ... ... @@ -560,11 +560,14 @@ 560 560 1. Operating record: it records user operations information, the records files are saved in HMI flash; its path is [~\~\flash~\~\UserOperationLogs.db]. 561 561 1. When it is on simulator mode, the files are saved in C disk, its path is [C:~\~\WECON\UserMgrFile\UserOperationLogs.db]. 562 562 596 +(% class="box infomessage" %) 597 +((( 563 563 ✎**Note: **The user name and password must be unique. 599 +))) 564 564 565 -== **Settings**==601 +== Settings == 566 566 567 - **Open PIStudio software, then operate as the following figure.**603 +Open PIStudio software, then operate as the following figure. 568 568 569 569 (% style="text-align:center" %) 570 570 [[image:用户权限 1.png||class="img-thumbnail"]] ... ... @@ -583,25 +583,26 @@ 583 583 * When the configured file does not have the administrator account, a new user can be added through "Funtion address" and set as the administrator. 584 584 * If you select hidden fucntion when configuring user account, the account would display as "~*~*~*~*~*~*" in the list. You only need to enter the password of the corresponding hidden user to log in. 585 585 586 -== **Object permission configuration**==622 +== Object permission configuration == 587 587 588 588 (% style="text-align:center" %) 589 589 [[image:用户权限 2.png||class="img-thumbnail"]] 590 590 591 - {{id name="OLE_LINK3"/}}{{id name="OLE_LINK4"/}}**Operation Procedure of Object Permission**627 +**Operation Procedure of Object Permission** 592 592 593 593 1. Open the object setting windows; 594 -1. Select [Security]windows;595 -1. Check the [User Permission];596 -1. Select [Level]to set permission level;597 -1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded;598 -1. Select the ~[[[Access Denied Setting>>path:#_Security]]]mode;630 +1. Select "Security" windows; 631 +1. Check the "User Permission"; 632 +1. Select "Level" to set permission level; 633 +1. Enter "Log Message", it is for operation records, if it was empty, the operation for this object would be not be recorded; 634 +1. Select the "Access Denied Setting" mode; 599 599 600 600 **Log information description** 601 601 602 -1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 603 -1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. 638 +A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 604 604 640 +The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. 641 + 605 605 The data format are as follows. 606 606 607 607 (% class="table-bordered" %) ... ... @@ -617,8 +617,7 @@ 617 617 |W|Single word 618 618 |D|Double word 619 619 620 -(% start="3" %) 621 -1. Examples. 657 +Examples. 622 622 623 623 * Unsigned decimal, BCD, 32-bit float and Signed decimal are as follows. 624 624 ... ... @@ -741,7 +741,7 @@ 741 741 742 742 [[https:~~/~~/drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq>>url:https://drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq]] 743 743 744 -= **{{id name="_Toc29015"/}}{{id name="_MessagePrompt"/}}MessagePrompt**=780 += Message prompt = 745 745 746 746 A message box is a window used to show some prompts or warnings to users. For example, the application process a task in the process of pop-up message box, suggesting that "U disk has been detected", then the customer can carry out data dump function. 747 747 ... ... @@ -808,12 +808,10 @@ 808 808 809 809 For example: 810 810 811 -~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100. 847 +* In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100. 848 +* For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 849 +* For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 812 812 813 -2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 814 - 815 -3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 816 - 817 817 **(2) Server Selection** 818 818 819 819 **Server**: China, ASEAN, and Europe.