Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -1,11 +1,11 @@ 1 1 (% class="wikigeneratedid" id="H8BasicFunction" %) 2 2 This chapter provides information about basic functions and configuration in PIStudio. 3 3 4 -= **Alarm** = 4 += **{{id name="_Toc28532"/}}Alarm** = 5 5 6 -== **Bit Alarm** ==6 +== **Bit alarm** == 7 7 8 -Click "Project"->"Bit Alarm", it is displayed as the following figure.8 +Click "Project"->"Bit alarm", it is displayed as the following figure. 9 9 10 10 (% style="text-align:center" %) 11 11 [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] ... ... @@ -18,7 +18,7 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig s eries and 8000/9000 series with -R after systemupgrade are supported)21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 22 22 23 23 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 24 24 ... ... @@ -60,7 +60,7 @@ 60 60 1. Other settings can be set according to the actual situation". 61 61 1. Click "OK" button to complete settings. 62 62 63 -== **Word Alarm** == 63 +== **{{id name="_Toc5343"/}}{{id name="_Word_alarm"/}}Word Alarm** == 64 64 65 65 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 66 66 ... ... @@ -77,7 +77,7 @@ 77 77 78 78 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 79 79 80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. ( (Only ig series and 8000/9000 series with -R after systemupgrade are supported))80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 81 81 82 82 **✎Note:** 83 83 ... ... @@ -762,7 +762,7 @@ 762 762 763 763 **For Example:** 764 764 765 -Trigger address is 011, during inserting 765 +Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message. 766 766 767 767 1. **Show message: **Check it to display message when HMI is running. It is checked by default. 768 768 1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default. ... ... @@ -781,14 +781,12 @@ 781 781 782 782 * If you do not want this prompt during the running of HMI, please uncheck "Show message". 783 783 * "Reload text" function would be invalid after clicking "save". 784 -* These 5 special characters are not supported in the header Multi 784 +* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&". 785 785 786 -= **Cloud** = 786 += **Cloud (Only ig series)** = 787 787 788 788 **Introduction** 789 789 790 -Cloud function is available for following models: the ig series and 8000/9000 series with -R after system upgrade 791 - 792 792 You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.) 793 793 794 794 Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. ... ... @@ -798,24 +798,56 @@ 798 798 799 799 **(1) Enable** 800 800 801 -If the HMI supports theCloudfunction,check ittoenable theCloudfunction,andit willcollectthe real-time datafrom HMIuploadto theCloud. The number ofdatacollection is limited,andthe specific parameters are as follows:799 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows. 802 802 803 -|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data 804 -|8000-R|300|200|100|1000 805 -|9000-R|300|200|100|1000 806 -|3000ig|100|20|50|500 807 -|8000ig|300|200|100|1000 801 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100. 802 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 803 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 808 808 809 - For example:805 +**{{id name="_GoBack"/}}(2) Server Selection** 810 810 811 - ~1.In 3000ig's Cloud, themonitoring tags upload to theloudinrealtimeis limitedto100.807 + **Server**: China, ASEAN, and Europe. 812 812 813 - 2.For 3000ig's Alarm, the Alarm recordsof word alarmsand bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] fordetails).809 + **Password**: 814 814 815 -3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 811 +1. If the HMI is not bound, this access password will be updated and downloaded into the HMI screen simultaneously. 812 +1. If the HMI is bound, this access password in the project cannot effectively change the binding password of the device, and it can only be changed through V-NET. 816 816 817 -**( 2)ServerSelection**814 +**(3) Upload Selection**: 818 818 816 +To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected. 817 + 818 +1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET. 819 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]". 820 + 821 +After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally. 822 + 823 +**4) Low Data Mode setting** 824 + 825 +1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default. 826 +1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags. 827 + 828 += **Cloud (Only ig series)** = 829 + 830 +**Introduction** 831 + 832 +You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.) 833 + 834 +Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. 835 + 836 +(% style="text-align:center" %) 837 +[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]] 838 + 839 +**(1) Enable** 840 + 841 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows. 842 + 843 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100. 844 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.4AlarmRecord]] for details) 845 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.3DataRecord]]) 846 + 847 +**{{id name="_GoBack"/}}(2) Server Selection** 848 + 819 819 **Server**: China, ASEAN, and Europe. 820 820 821 821 **Password**: ... ... @@ -828,7 +828,7 @@ 828 828 To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected. 829 829 830 830 1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET. 831 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".861 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to [[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#H10.19CloudInterface]]. 832 832 833 833 After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally. 834 834