Changes for page 06 Data Tool

Last modified by Jett on 2025/02/18 16:43

From version 12.1
edited by Hunter
on 2022/07/09 10:40
Change comment: There is no comment for this version
To version 3.3
edited by Stone Wu
on 2022/06/30 11:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Stone
Content
... ... @@ -1,11 +1,11 @@
1 1  (% class="wikigeneratedid" id="H8BasicFunction" %)
2 2  This chapter provides information about basic functions and configuration in PIStudio.
3 3  
4 -= **Alarm** =
4 += **{{id name="_Toc28532"/}}Alarm** =
5 5  
6 -== **Bit Alarm** ==
6 +== **Bit alarm** ==
7 7  
8 -Click "Project"->"Bit Alarm", it is displayed as the following figure.
8 +Click "Project"->"Bit alarm", it is displayed as the following figure.
9 9  
10 10  (% style="text-align:center" %)
11 11  [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]]
... ... @@ -18,21 +18,8 @@
18 18  1. **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
19 19  1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
20 20  
21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
22 22  
23 -**✎Note:**
24 -
25 -(1) After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
26 -
27 -(2) The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
28 -
29 -(% style="margin-left:auto; margin-right:auto; width:358px" %)
30 -|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
31 -|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
32 -|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
33 -|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
34 -|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
35 -
36 36  **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
37 37  
38 38  **(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
... ... @@ -73,7 +73,7 @@
73 73  1. Other settings can be set according to the actual situation".
74 74  1. Click "OK" button to complete settings.
75 75  
76 -== **Word Alarm** ==
63 +== **{{id name="_Toc5343"/}}{{id name="_Word_alarm"/}}Word Alarm** ==
77 77  
78 78  Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated.
79 79  
... ... @@ -90,7 +90,7 @@
90 90  
91 91  **(4)  Group No.: **Group number of word alarm. The name is unique and cannot be duplicated.
92 92  
93 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. ((Only ig series and 8000/9000 series with -R after system upgrade are supported))
80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
94 94  
95 95  **✎Note:**
96 96  
... ... @@ -379,7 +379,7 @@
379 379  
380 380  **(1) Basic settings**
381 381  
382 -1. **Curve NO.: **It is for setting curve number,
369 +1. **Curve NO.: **It is for setting curvenumber,
383 383  1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes.
384 384  1. **Curve (1~~8):** It is for setting the number of curves. The default is 3.
385 385  1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves.
... ... @@ -386,7 +386,7 @@
386 386  
387 387  **(2) Sample Type**
388 388  
389 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit.
376 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.
390 390  1. **Sample unit:** 100ms.
391 391  
392 392  **(3) Quick Setting**
... ... @@ -397,7 +397,7 @@
397 397  [[image:趋势图设置 3.png||class="img-thumbnail"]]
398 398  
399 399  (% start="2" %)
400 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
387 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
401 401  
402 402  **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content.
403 403  
... ... @@ -421,7 +421,7 @@
421 421  
422 422  **(1) Basic settings**
423 423  
424 -1. **Curve NO.: **It is for setting curve number,
411 +1. **Curve NO.: **It is for setting curvenumber,
425 425  1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes.
426 426  1. **Curve (1~~8):** It is for setting the number of curves. The default is 3.
427 427  1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves.
... ... @@ -428,7 +428,7 @@
428 428  
429 429  **(2) Sample Type**
430 430  
431 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit.
418 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.
432 432  1. **Sample unit:** 100ms.
433 433  
434 434  **(3) Quick Setting**
... ... @@ -439,7 +439,7 @@
439 439  [[image:image-20220616145435-1.png]]
440 440  
441 441  (% start="2" %)
442 -1. **Sample address: **Fill in the start address that read the device data. If the sample address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
429 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
443 443  
444 444  **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content.
445 445  
... ... @@ -476,7 +476,7 @@
476 476  
477 477  The data record stored in SD card is also organized according to the above figure.
478 478  
479 -The sample time and save time is consistent in the same record group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.
466 +The sample time and save time is consistent in the same recored group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.
480 480  
481 481  **Sampling interval: **The interval between two consecutive samples was recorded.
482 482  
... ... @@ -524,7 +524,7 @@
524 524  1. **Trigger to record by sample cycle: **Data will be recorded in every same time, when trigger control bit set ON.
525 525  1. **Trigger to record once and reset: **Data will be recorded when trigger control bit set ON, and the bit will be reset automatically.
526 526  1. **Trigger to record once: **Data will be recorded when trigger control bit set ON, and the bit need to be reset manually.
527 -1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycle for trigger sampling address is 1s.
514 +1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cyclce for trigger sampling address is 1s.
528 528  
529 529  **(3) Total channels (1~~100): **Set the numbers of channels. Click "apply" to view the channel lists on the right record channel.
530 530  
... ... @@ -540,8 +540,8 @@
540 540  
541 541  **(7) Quick Settings**
542 542  
543 -1. **Start Channel:** It sets the continuous addresses for channels.
544 -1. **Data Format: **It sets the same data format for channels.
530 +1. **Start Channel:** It sets the continuous addressesfor channels.
531 +1. **Data Format: **It setsthe samedata format for channels.
545 545  1. **Number of Digits:** It sets the digits’ number for channels.
546 546  1. **Language Settings**: The text in HMI can be in 8 languages, user can set language in here.
547 547  
... ... @@ -583,7 +583,7 @@
583 583  [[image:用户权限 1.png||class="img-thumbnail"]]
584 584  
585 585  1. Click "User Permission" in "Data Tool" toolbar.
586 -1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users.
573 +1. Edit user name, click "User0" cellunder "UserName", and then enter the user name, one project allows maximum 20 users.
587 587  1. Edit password, click "User0" cell under "PassWord", and then enter the user name.
588 588  1. Edit description, click "User0" cell under "Desc", and then enter, description is not necessary。
589 589  1. Check the groups for each user, there are 11 groups beside admin.
... ... @@ -610,7 +610,7 @@
610 610  1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded;
611 611  1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode;
612 612  
613 -**Log information description**
600 +**Log imformation description**
614 614  
615 615  1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
616 616  1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
... ... @@ -775,7 +775,7 @@
775 775  
776 776  **For Example:**
777 777  
778 -Trigger address is 011, during inserting a USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
765 +Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
779 779  
780 780  1. **Show message: **Check it to display message when HMI is running. It is checked by default.
781 781  1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default.
... ... @@ -794,14 +794,12 @@
794 794  
795 795  * If you do not want this prompt during the running of HMI, please uncheck "Show message".
796 796  * "Reload text" function would be invalid after clicking "save".
797 -* These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&".
784 +* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&".
798 798  
799 -= **Cloud** =
786 += **Cloud (Only ig series)** =
800 800  
801 801  **Introduction**
802 802  
803 -Cloud function is available for following models: the ig series and 8000/9000 series with -R after system upgrade
804 -
805 805  You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
806 806  
807 807  Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
... ... @@ -811,24 +811,56 @@
811 811  
812 812  **(1) Enable**
813 813  
814 -If the HMI supports the Cloud function, check it to enable the Cloud function, and it will collect the real-time data from HMI upload to the Cloud. The number of data collection is limited, and the specific parameters are as follows:
799 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
815 815  
816 -|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data
817 -|8000-R|300|200|100|1000
818 -|9000-R|300|200|100|1000
819 -|3000ig|100|20|50|500
820 -|8000ig|300|200|100|1000
801 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
802 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
803 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
821 821  
822 -For example:
805 +**{{id name="_GoBack"/}}(2) Server Selection**
823 823  
824 -~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
807 + **Server**: China, ASEAN, and Europe.
825 825  
826 -2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
809 + **Password**:
827 827  
828 -3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
811 +1. If the HMI is not bound, this access password will be updated and downloaded into the HMI screen simultaneously.
812 +1. If the HMI is bound, this access password in the project cannot effectively change the binding password of the device, and it can only be changed through V-NET.
829 829  
830 -**(2) Server Selection**
814 +**(3) Upload Selection**
831 831  
816 +To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected.
817 +
818 +1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET.
819 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".
820 +
821 +After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally.
822 +
823 +**4) Low Data Mode setting**
824 +
825 +1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default.
826 +1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags.
827 +
828 += **Cloud (Only ig series)** =
829 +
830 +**Introduction**
831 +
832 +You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
833 +
834 +Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
835 +
836 +(% style="text-align:center" %)
837 +[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]]
838 +
839 +**(1) Enable**
840 +
841 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
842 +
843 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
844 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.4AlarmRecord]] for details)
845 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.3DataRecord]])
846 +
847 +**{{id name="_GoBack"/}}(2) Server Selection**
848 +
832 832   **Server**: China, ASEAN, and Europe.
833 833  
834 834   **Password**:
... ... @@ -841,7 +841,7 @@
841 841  To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected.
842 842  
843 843  1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET.
844 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".
861 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to [[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#H10.19CloudInterface]].
845 845  
846 846  After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally.
847 847