Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -1,11 +1,11 @@ 1 1 (% class="wikigeneratedid" id="H8BasicFunction" %) 2 2 This chapter provides information about basic functions and configuration in PIStudio. 3 3 4 -= **Alarm** = 4 += **{{id name="_Toc28532"/}}Alarm** = 5 5 6 -== **Bit Alarm** ==6 +== **Bit alarm** == 7 7 8 -Click "Project"->"Bit Alarm", it is displayed as the following figure.8 +Click "Project"->"Bit alarm", it is displayed as the following figure. 9 9 10 10 (% style="text-align:center" %) 11 11 [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] ... ... @@ -18,21 +18,8 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig s eries and 8000/9000 series with -R after systemupgrade are supported)21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 22 22 23 -**✎Note:** 24 - 25 -(1) After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 26 - 27 -(2) The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 28 - 29 -(% style="margin-left:auto; margin-right:auto; width:358px" %) 30 -|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 31 -|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 32 -|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 33 -|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 34 -|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 35 - 36 36 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 37 37 38 38 **(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. ... ... @@ -73,7 +73,7 @@ 73 73 1. Other settings can be set according to the actual situation". 74 74 1. Click "OK" button to complete settings. 75 75 76 -== **Word Alarm** == 63 +== **{{id name="_Toc5343"/}}{{id name="_Word_alarm"/}}Word Alarm** == 77 77 78 78 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 79 79 ... ... @@ -90,7 +90,7 @@ 90 90 91 91 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 92 92 93 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. ( (Only ig series and 8000/9000 series with -R after systemupgrade are supported))80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 94 94 95 95 **✎Note:** 96 96 ... ... @@ -476,7 +476,7 @@ 476 476 477 477 The data record stored in SD card is also organized according to the above figure. 478 478 479 -The sample time and save time is consistent in the same record group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address. 466 +The sample time and save time is consistent in the same recored group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address. 480 480 481 481 **Sampling interval: **The interval between two consecutive samples was recorded. 482 482 ... ... @@ -524,7 +524,7 @@ 524 524 1. **Trigger to record by sample cycle: **Data will be recorded in every same time, when trigger control bit set ON. 525 525 1. **Trigger to record once and reset: **Data will be recorded when trigger control bit set ON, and the bit will be reset automatically. 526 526 1. **Trigger to record once: **Data will be recorded when trigger control bit set ON, and the bit need to be reset manually. 527 -1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycle for trigger sampling address is 1s. 514 +1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cyclce for trigger sampling address is 1s. 528 528 529 529 **(3) Total channels (1~~100): **Set the numbers of channels. Click "apply" to view the channel lists on the right record channel. 530 530 ... ... @@ -540,8 +540,8 @@ 540 540 541 541 **(7) Quick Settings** 542 542 543 -1. **Start Channel:** It sets the continuous addresses 544 -1. **Data Format: **It sets 530 +1. **Start Channel:** It sets the continuous addressesfor channels. 531 +1. **Data Format: **It setsthe samedata format for channels. 545 545 1. **Number of Digits:** It sets the digits’ number for channels. 546 546 1. **Language Settings**: The text in HMI can be in 8 languages, user can set language in here. 547 547 ... ... @@ -583,7 +583,7 @@ 583 583 [[image:用户权限 1.png||class="img-thumbnail"]] 584 584 585 585 1. Click "User Permission" in "Data Tool" toolbar. 586 -1. Edit user name, click "User0" cell 573 +1. Edit user name, click "User0" cellunder "UserName", and then enter the user name, one project allows maximum 20 users. 587 587 1. Edit password, click "User0" cell under "PassWord", and then enter the user name. 588 588 1. Edit description, click "User0" cell under "Desc", and then enter, description is not necessary。 589 589 1. Check the groups for each user, there are 11 groups beside admin. ... ... @@ -610,7 +610,7 @@ 610 610 1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded; 611 611 1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode; 612 612 613 -**Log i nformation description**600 +**Log imformation description** 614 614 615 615 1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 616 616 1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. ... ... @@ -775,7 +775,7 @@ 775 775 776 776 **For Example:** 777 777 778 -Trigger address is 011, during inserting 765 +Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message. 779 779 780 780 1. **Show message: **Check it to display message when HMI is running. It is checked by default. 781 781 1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default. ... ... @@ -794,14 +794,12 @@ 794 794 795 795 * If you do not want this prompt during the running of HMI, please uncheck "Show message". 796 796 * "Reload text" function would be invalid after clicking "save". 797 -* These 5 special characters are not supported in the header Multi 784 +* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&". 798 798 799 -= **Cloud** = 786 += **Cloud (Only ig series)** = 800 800 801 801 **Introduction** 802 802 803 -Cloud function is available for following models: the ig series and 8000/9000 series with -R after system upgrade 804 - 805 805 You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.) 806 806 807 807 Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. ... ... @@ -811,24 +811,56 @@ 811 811 812 812 **(1) Enable** 813 813 814 -If the HMI supports theCloudfunction,check ittoenable theCloudfunction,andit willcollectthe real-time datafrom HMIuploadto theCloud. The number ofdatacollection is limited,andthe specific parameters are as follows:799 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows. 815 815 816 -|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data 817 -|8000-R|300|200|100|1000 818 -|9000-R|300|200|100|1000 819 -|3000ig|100|20|50|500 820 -|8000ig|300|200|100|1000 801 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100. 802 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 803 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 821 821 822 - For example:805 +**{{id name="_GoBack"/}}(2) Server Selection** 823 823 824 - ~1.In 3000ig's Cloud, themonitoring tags upload to theloudinrealtimeis limitedto100.807 + **Server**: China, ASEAN, and Europe. 825 825 826 - 2.For 3000ig's Alarm, the Alarm recordsof word alarmsand bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] fordetails).809 + **Password**: 827 827 828 -3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 811 +1. If the HMI is not bound, this access password will be updated and downloaded into the HMI screen simultaneously. 812 +1. If the HMI is bound, this access password in the project cannot effectively change the binding password of the device, and it can only be changed through V-NET. 829 829 830 -**( 2)ServerSelection**814 +**(3) Upload Selection**: 831 831 816 +To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected. 817 + 818 +1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET. 819 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]". 820 + 821 +After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally. 822 + 823 +**4) Low Data Mode setting** 824 + 825 +1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default. 826 +1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags. 827 + 828 += **Cloud (Only ig series)** = 829 + 830 +**Introduction** 831 + 832 +You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.) 833 + 834 +Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. 835 + 836 +(% style="text-align:center" %) 837 +[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]] 838 + 839 +**(1) Enable** 840 + 841 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows. 842 + 843 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100. 844 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.4AlarmRecord]] for details) 845 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.3DataRecord]]) 846 + 847 +**{{id name="_GoBack"/}}(2) Server Selection** 848 + 832 832 **Server**: China, ASEAN, and Europe. 833 833 834 834 **Password**: ... ... @@ -841,7 +841,7 @@ 841 841 To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected. 842 842 843 843 1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET. 844 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".861 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to [[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#H10.19CloudInterface]]. 845 845 846 846 After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally. 847 847