1 1  (% class="wikigeneratedid" id="H8BasicFunction" %)
2 -This chapter provides information about basic functions and configuration in PIStudio.
2 +This chapter provides information about basic functions and configiration in PIStudio.
3 3  
4 -= **Alarm** =
4 += **{{id name="_Toc28532"/}}Alarm** =
5 5  
6 6  == **Bit Alarm** ==
7 7  
8 -Click "Project"->"Bit Alarm", it is displayed as the following figure.
8 +Click "Project"->"Bit alarm", it is displayed as the following figure.
9 9  
10 10  (% style="text-align:center" %)
11 11  [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]]
... ... @@ -18,20 +18,8 @@
18 18  1. **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
19 19  1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
20 20  
21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud aand it is alarm data. (Only ig supported)
22 22  
23 -**✎Note:**
24 -
25 -* After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
26 -* The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
27 -
28 -(% style="margin-left:auto; margin-right:auto; width:358px" %)
29 -|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
30 -|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
31 -|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
32 -|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
33 -|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
34 -
35 35  **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
36 36  
37 37  **(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
... ... @@ -49,7 +49,7 @@
49 49  
50 50  **✎Note:**
51 51  
52 -* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
40 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communnication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
53 53  * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure.
54 54  
55 55  **Operating Procedures of Adding One Alarm**
... ... @@ -72,11 +72,11 @@
72 72  1. Other settings can be set according to the actual situation".
73 73  1. Click "OK" button to complete settings.
74 74  
75 -== **Word Alarm** ==
63 +== **{{id name="_Toc5343"/}}{{id name="_Word_alarm"/}}Word Alarm** ==
76 76  
77 77  Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated.
78 78  
79 -Click "Project"->"Word alarm", it is displayed as the following figure.
67 +Click "Porject"->"Word alarm", it is displayed as the following figure.
80 80  
81 81  (% style="text-align:center" %)
82 82  [[image:字报警 1.png||class="img-thumbnail"]]
... ... @@ -89,20 +89,13 @@
89 89  
90 90  **(4)  Group No.: **Group number of word alarm. The name is unique and cannot be duplicated.
91 91  
92 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud aand it is alarm data. (Only ig supported)
93 93  
94 94  **✎Note:**
95 95  
96 -* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
84 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communnication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
97 97  * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure.
98 98  
99 -(% style="margin-left:auto; margin-right:auto; width:358px" %)
100 -|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
101 -|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
102 -|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
103 -|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
104 -|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
105 -
106 106  **(6) Record alarm:**  Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location.
107 107  
108 108  **(7) Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
... ... @@ -169,7 +169,7 @@
169 169  
170 170  The maximum number of group in recipe is 1000, and the maximum number of member in each group is 1500.
171 171  
172 -Recipe could store the data in USB flash disk and SD card and view the recipe data by object "Recipe display". It has two mode: simple mode and advanced mode.
153 +Recipe could store the data in USB flash disk and SD card and view the recipe data by obejct "Recipe display". It has two mode: simple mode and advanced mode.
173 173  
174 174  1. **Simple: **Only support the data operation of one recipe file, including read and write.
175 175  1. **Advanced:** Support the data operation of multiple recipe files, including read, write, insert and index. View and select recipe file by object "File list".
... ... @@ -292,9 +292,9 @@
292 292  
293 293  == **Recipe display** ==
294 294  
295 -Select the file type "Traditional recipe file" in object "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.
276 +Select the file type "Traditional recipe file" in onject "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.
296 296  
297 -**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as following shown:
278 +**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as follwoing shown:
298 298  
299 299  (% style="text-align:center" %)
300 300  [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]]
... ... @@ -385,7 +385,7 @@
385 385  
386 386  **(1) Basic settings**
387 387  
388 -1. **Curve NO.: **It is for setting curve number,
369 +1. **Curve NO.: **It is for setting curvenumber,
389 389  1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes.
390 390  1. **Curve (1~~8):** It is for setting the number of curves. The default is 3.
391 391  1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves.
... ... @@ -392,7 +392,7 @@
392 392  
393 393  **(2) Sample Type**
394 394  
395 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit.
376 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.
396 396  1. **Sample unit:** 100ms.
397 397  
398 398  **(3) Quick Setting**
... ... @@ -403,7 +403,7 @@
403 403  [[image:趋势图设置 3.png||class="img-thumbnail"]]
404 404  
405 405  (% start="2" %)
406 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
387 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
407 407  
408 408  **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content.
409 409  
... ... @@ -427,7 +427,7 @@
427 427  
428 428  **(1) Basic settings**
429 429  
430 -1. **Curve NO.: **It is for setting curve number,
411 +1. **Curve NO.: **It is for setting curvenumber,
431 431  1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes.
432 432  1. **Curve (1~~8):** It is for setting the number of curves. The default is 3.
433 433  1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves.
... ... @@ -434,7 +434,7 @@
434 434  
435 435  **(2) Sample Type**
436 436  
437 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit.
418 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.
438 438  1. **Sample unit:** 100ms.
439 439  
440 440  **(3) Quick Setting**
... ... @@ -445,7 +445,7 @@
445 445  [[image:image-20220616145435-1.png]]
446 446  
447 447  (% start="2" %)
448 -1. **Sample address: **Fill in the start address that read the device data. If the sample address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
429 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
449 449  
450 450  **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content.
451 451  
... ... @@ -482,7 +482,7 @@
482 482  
483 483  The data record stored in SD card is also organized according to the above figure.
484 484  
485 -The sample time and save time is consistent in the same record group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.
466 +The sample time and save time is consistent in the same recored group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.
486 486  
487 487  **Sampling interval: **The interval between two consecutive samples was recorded.
488 488  
... ... @@ -530,7 +530,7 @@
530 530  1. **Trigger to record by sample cycle: **Data will be recorded in every same time, when trigger control bit set ON.
531 531  1. **Trigger to record once and reset: **Data will be recorded when trigger control bit set ON, and the bit will be reset automatically.
532 532  1. **Trigger to record once: **Data will be recorded when trigger control bit set ON, and the bit need to be reset manually.
533 -1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycle for trigger sampling address is 1s.
514 +1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cyclce for trigger sampling address is 1s.
534 534  
535 535  **(3) Total channels (1~~100): **Set the numbers of channels. Click "apply" to view the channel lists on the right record channel.
536 536  
... ... @@ -546,8 +546,8 @@
546 546  
547 547  **(7) Quick Settings**
548 548  
549 -1. **Start Channel:** It sets the continuous addresses for channels.
550 -1. **Data Format: **It sets the same data format for channels.
530 +1. **Start Channel:** It sets the continuous addressesfor channels.
531 +1. **Data Format: **It setsthe samedata format for channels.
551 551  1. **Number of Digits:** It sets the digits’ number for channels.
552 552  1. **Language Settings**: The text in HMI can be in 8 languages, user can set language in here.
553 553  
... ... @@ -589,7 +589,7 @@
589 589  [[image:用户权限 1.png||class="img-thumbnail"]]
590 590  
591 591  1. Click "User Permission" in "Data Tool" toolbar.
592 -1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users.
573 +1. Edit user name, click "User0" cellunder "UserName", and then enter the user name, one project allows maximum 20 users.
593 593  1. Edit password, click "User0" cell under "PassWord", and then enter the user name.
594 594  1. Edit description, click "User0" cell under "Desc", and then enter, description is not necessary。
595 595  1. Check the groups for each user, there are 11 groups beside admin.
... ... @@ -616,7 +616,7 @@
616 616  1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded;
617 617  1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode;
618 618  
619 -**Log information description**
600 +**Log imformation description**
620 620  
621 621  1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
622 622  1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
... ... @@ -781,7 +781,7 @@
781 781  
782 782  **For Example:**
783 783  
784 -Trigger address is 011, during inserting a USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
765 +Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
785 785  
786 786  1. **Show message: **Check it to display message when HMI is running. It is checked by default.
787 787  1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default.
... ... @@ -800,14 +800,12 @@
800 800  
801 801  * If you do not want this prompt during the running of HMI, please uncheck "Show message".
802 802  * "Reload text" function would be invalid after clicking "save".
803 -* These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&".
784 +* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&".
804 804  
805 -= **Cloud** =
786 += **Cloud (Only ig series)** =
806 806  
807 807  **Introduction**
808 808  
809 -Cloud function is available for following models: the ig series and 8000/9000 series with -R after system upgrade
810 -
811 811  You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
812 812  
813 813  Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
... ... @@ -817,24 +817,56 @@
817 817  
818 818  **(1) Enable**
819 819  
820 -If the HMI supports the Cloud function, check it to enable the Cloud function, and it will collect the real-time data from HMI upload to the Cloud. The number of data collection is limited, and the specific parameters are as follows:
799 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
821 821  
822 -|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data
823 -|8000-R|300|200|100|1000
824 -|9000-R|300|200|100|1000
825 -|3000ig|100|20|50|500
826 -|8000ig|300|200|100|1000
801 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
802 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
803 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
827 827  
828 -For example:
805 +**{{id name="_GoBack"/}}(2) Server Selection**
829 829  
830 -~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
807 + **Server**: China, ASEAN, and Europe.
831 831  
832 -2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
809 + **Password**:
833 833  
834 -3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
811 +1. If the HMI is not bound, this access password will be updated and downloaded into the HMI screen simultaneously.
812 +1. If the HMI is bound, this access password in the project cannot effectively change the binding password of the device, and it can only be changed through V-NET.
835 835  
836 -**(2) Server Selection**
814 +**(3) Upload Selection**
837 837  
816 +To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected.
817 +
818 +1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET.
819 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".
820 +
821 +After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally.
822 +
823 +**4) Low Data Mode setting**
824 +
825 +1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default.
826 +1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags.
827 +
828 += **Cloud (Only ig series)** =
829 +
830 +**Introduction**
831 +
832 +You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
833 +
834 +Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
835 +
836 +(% style="text-align:center" %)
837 +[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]]
838 +
839 +**(1) Enable**
840 +
841 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
842 +
843 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
844 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.4AlarmRecord]] for details)
845 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.3DataRecord]])
846 +
847 +**{{id name="_GoBack"/}}(2) Server Selection**
848 +
838 838   **Server**: China, ASEAN, and Europe.
839 839  
840 840   **Password**:
... ... @@ -847,7 +847,7 @@
847 847  To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected.
848 848  
849 849  1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET.
850 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".
861 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to [[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#H10.19CloudInterface]].
851 851  
852 852  After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally.
853 853