Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -1,11 +1,11 @@ 1 1 (% class="wikigeneratedid" id="H8BasicFunction" %) 2 2 This chapter provides information about basic functions and configuration in PIStudio. 3 3 4 -= **Alarm** = 4 += **{{id name="_Toc28532"/}}Alarm** = 5 5 6 -== **Bit Alarm** ==6 +== **Bit alarm** == 7 7 8 -Click "Project"->"Bit Alarm", it is displayed as the following figure.8 +Click "Project"->"Bit alarm", it is displayed as the following figure. 9 9 10 10 (% style="text-align:center" %) 11 11 [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] ... ... @@ -18,20 +18,8 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig s eries and 8000/9000 series with -R after systemupgrade are supported)21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 22 22 23 -**✎Note:** 24 - 25 -* After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 26 -* The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 27 - 28 -(% style="margin-left:auto; margin-right:auto; width:358px" %) 29 -|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 30 -|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 31 -|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 32 -|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 33 -|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 34 - 35 35 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 36 36 37 37 **(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. ... ... @@ -72,7 +72,7 @@ 72 72 1. Other settings can be set according to the actual situation". 73 73 1. Click "OK" button to complete settings. 74 74 75 -== **Word Alarm** == 63 +== **{{id name="_Toc5343"/}}{{id name="_Word_alarm"/}}Word Alarm** == 76 76 77 77 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 78 78 ... ... @@ -89,7 +89,7 @@ 89 89 90 90 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 91 91 92 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig s eries and 8000/9000 series with -R after systemupgrade are supported)80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 93 93 94 94 **✎Note:** 95 95 ... ... @@ -96,13 +96,6 @@ 96 96 * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 97 97 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 98 98 99 -(% style="margin-left:auto; margin-right:auto; width:358px" %) 100 -|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 101 -|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 102 -|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 103 -|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 104 -|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 105 - 106 106 **(6) Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. 107 107 108 108 **(7) Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. ... ... @@ -802,12 +802,10 @@ 802 802 * "Reload text" function would be invalid after clicking "save". 803 803 * These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&". 804 804 805 -= **Cloud** = 786 += **Cloud (Only ig series)** = 806 806 807 807 **Introduction** 808 808 809 -Cloud function is available for following models: the ig series and 8000/9000 series with -R after system upgrade 810 - 811 811 You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.) 812 812 813 813 Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. ... ... @@ -817,24 +817,14 @@ 817 817 818 818 **(1) Enable** 819 819 820 -If the HMI supports theCloudfunction,check ittoenable theCloudfunction,andit willcollectthe real-time datafrom HMIuploadto theCloud. The number ofdatacollection is limited,andthe specific parameters are as follows:799 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows. 821 821 822 -|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data 823 -|8000-R|300|200|100|1000 824 -|9000-R|300|200|100|1000 825 -|3000ig|100|20|50|500 826 -|8000ig|300|200|100|1000 801 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100. 802 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 803 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 827 827 828 - For example:805 +**{{id name="_GoBack"/}}(2) Server Selection** 829 829 830 -~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100. 831 - 832 -2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 833 - 834 -3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 835 - 836 -**(2) Server Selection** 837 - 838 838 **Server**: China, ASEAN, and Europe. 839 839 840 840 **Password**: