Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,9 +22,10 @@ 22 22 23 23 **✎Note:** 24 24 25 -* After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 26 -* The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 25 +(1) After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 27 27 27 +(2) The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 28 + 28 28 (% style="margin-left:auto; margin-right:auto; width:358px" %) 29 29 |=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 30 30 |(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 ... ... @@ -89,7 +89,7 @@ 89 89 90 90 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 91 91 92 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 93 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. ((Only ig series and 8000/9000 series with -R after system upgrade are supported)) 93 93 94 94 **✎Note:** 95 95 ... ... @@ -96,13 +96,6 @@ 96 96 * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 97 97 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 98 98 99 -(% style="margin-left:auto; margin-right:auto; width:358px" %) 100 -|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 101 -|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 102 -|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 103 -|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 104 -|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 105 - 106 106 **(6) Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. 107 107 108 108 **(7) Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. ... ... @@ -490,17 +490,8 @@ 490 490 491 491 For the file storage of data, see the file size configuration during data record configuration. 492 492 493 -✎**Note: ** 487 +✎**Note: **The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters. 494 494 495 -1) 496 - 497 -2) 498 - 499 -3) The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters. 500 - 501 -4) Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ". 502 - 503 - 504 504 (% class="wikigeneratedid" id="HSettings" %) 505 505 **Settings** 506 506