Changes for page 06 Data Tool

Last modified by Jett on 2025/02/18 16:43

From version 16.1
edited by Hunter
on 2022/07/09 11:12
Change comment: There is no comment for this version
To version 3.5
edited by Stone Wu
on 2022/06/30 11:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Stone
Content
... ... @@ -1,11 +1,11 @@
1 1  (% class="wikigeneratedid" id="H8BasicFunction" %)
2 2  This chapter provides information about basic functions and configuration in PIStudio.
3 3  
4 -= **Alarm** =
4 += **{{id name="_Toc28532"/}}Alarm** =
5 5  
6 -== **Bit Alarm** ==
6 +== **Bit alarm** ==
7 7  
8 -Click "Project"->"Bit Alarm", it is displayed as the following figure.
8 +Click "Project"->"Bit alarm", it is displayed as the following figure.
9 9  
10 10  (% style="text-align:center" %)
11 11  [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]]
... ... @@ -18,20 +18,8 @@
18 18  1. **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
19 19  1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
20 20  
21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
22 22  
23 -**✎Note:**
24 -
25 -* After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
26 -* The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
27 -
28 -(% style="margin-left:auto; margin-right:auto; width:358px" %)
29 -|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
30 -|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
31 -|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
32 -|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
33 -|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
34 -
35 35  **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
36 36  
37 37  **(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
... ... @@ -72,7 +72,7 @@
72 72  1. Other settings can be set according to the actual situation".
73 73  1. Click "OK" button to complete settings.
74 74  
75 -== **Word Alarm** ==
63 +== **{{id name="_Toc5343"/}}{{id name="_Word_alarm"/}}Word Alarm** ==
76 76  
77 77  Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated.
78 78  
... ... @@ -89,7 +89,7 @@
89 89  
90 90  **(4)  Group No.: **Group number of word alarm. The name is unique and cannot be duplicated.
91 91  
92 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
93 93  
94 94  **✎Note:**
95 95  
... ... @@ -96,13 +96,6 @@
96 96  * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
97 97  * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure.
98 98  
99 -(% style="margin-left:auto; margin-right:auto; width:358px" %)
100 -|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
101 -|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
102 -|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
103 -|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
104 -|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
105 -
106 106  **(6) Record alarm:**  Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location.
107 107  
108 108  **(7) Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
... ... @@ -490,24 +490,8 @@
490 490  
491 491  For the file storage of data, see the file size configuration during data record configuration.
492 492  
493 -✎**Note: **
474 +✎**Note: **The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.
494 494  
495 -1) After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Data record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
496 -
497 -2) The number of Data records upload to Cloud shall not exceed the limit value, or the sum of the imported Data records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
498 -
499 -(% style="margin-left:auto; margin-right:auto; width:513px" %)
500 -|=(% style="width: 70px;" %)Series|=(% style="width: 442px;" %)Number of Data Record upload to Cloud
501 -|(% style="width:70px" %)8000-R|(% style="text-align:center; width:442px" %)100
502 -|(% style="width:70px" %)9000-R|(% style="text-align:center; width:442px" %)100
503 -|(% style="width:70px" %)3000ig|(% style="text-align:center; width:442px" %)50
504 -|(% style="width:70px" %)8000ig|(% style="text-align:center; width:442px" %)100
505 -
506 -3) The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.
507 -
508 -4) Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ".
509 -
510 -
511 511  (% class="wikigeneratedid" id="HSettings" %)
512 512  **Settings**
513 513  
... ... @@ -797,7 +797,7 @@
797 797  
798 798  **For Example:**
799 799  
800 -Trigger address is 011, during inserting a USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
765 +Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
801 801  
802 802  1. **Show message: **Check it to display message when HMI is running. It is checked by default.
803 803  1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default.
... ... @@ -816,14 +816,12 @@
816 816  
817 817  * If you do not want this prompt during the running of HMI, please uncheck "Show message".
818 818  * "Reload text" function would be invalid after clicking "save".
819 -* These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&".
784 +* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&".
820 820  
821 -= **Cloud** =
786 += **Cloud (Only ig series)** =
822 822  
823 823  **Introduction**
824 824  
825 -Cloud function is available for following models: the ig series and 8000/9000 series with -R after system upgrade
826 -
827 827  You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
828 828  
829 829  Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
... ... @@ -833,24 +833,56 @@
833 833  
834 834  **(1) Enable**
835 835  
836 -If the HMI supports the Cloud function, check it to enable the Cloud function, and it will collect the real-time data from HMI upload to the Cloud. The number of data collection is limited, and the specific parameters are as follows:
799 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
837 837  
838 -|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data
839 -|8000-R|300|200|100|1000
840 -|9000-R|300|200|100|1000
841 -|3000ig|100|20|50|500
842 -|8000ig|300|200|100|1000
801 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
802 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
803 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
843 843  
844 -For example:
805 +**{{id name="_GoBack"/}}(2) Server Selection**
845 845  
846 -~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
807 + **Server**: China, ASEAN, and Europe.
847 847  
848 -2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
809 + **Password**:
849 849  
850 -3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
811 +1. If the HMI is not bound, this access password will be updated and downloaded into the HMI screen simultaneously.
812 +1. If the HMI is bound, this access password in the project cannot effectively change the binding password of the device, and it can only be changed through V-NET.
851 851  
852 -**(2) Server Selection**
814 +**(3) Upload Selection**
853 853  
816 +To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected.
817 +
818 +1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET.
819 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".
820 +
821 +After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally.
822 +
823 +**4) Low Data Mode setting**
824 +
825 +1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default.
826 +1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags.
827 +
828 += **Cloud (Only ig series)** =
829 +
830 +**Introduction**
831 +
832 +You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
833 +
834 +Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
835 +
836 +(% style="text-align:center" %)
837 +[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]]
838 +
839 +**(1) Enable**
840 +
841 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
842 +
843 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
844 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.4AlarmRecord]] for details)
845 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.3DataRecord]])
846 +
847 +**{{id name="_GoBack"/}}(2) Server Selection**
848 +
854 854   **Server**: China, ASEAN, and Europe.
855 855  
856 856   **Password**:
... ... @@ -863,7 +863,7 @@
863 863  To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected.
864 864  
865 865  1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET.
866 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".
861 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to [[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#H10.19CloudInterface]].
867 867  