Changes for page 06 Data Tool
Last modified by Joe on 2026/10/24 10:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -219,18 +219,19 @@ 219 219 |Bottom|3|1|2|40 220 220 |Outside|2|3|3|20 221 221 222 -From the above table, one group of recipes is needed when spraying different parts, and three groups of recipes can be established, and each group of recipes has four ingredients: Red, Green, Blue, Spraying time. The value of each ingredient is different in different groups of recipes.**Recipe configuration** 222 +From the above table, one group of recipes is needed when spraying different parts, and three groups of recipes can be established, and each group of recipes has four ingredients: Red, Green, Blue, Spraying time. The value of each ingredient is different in different groups of recipes. **Recipe configuration** 223 223 224 224 The recipe function needs to be used with the recipe configuration area and [Recipe record] object. Click [Recipe] in the [System configuration/Record setting] in the upper left side of the software [[image:1698393787529-717.png]]and the following interface will pop up: 225 + 225 225 226 226 (% style="text-align:center" %) 227 -[[image: 1.png]]228 +[[image:taavZYE8GK.png]] 228 228 229 -Click [Add] to pop up the recipe setting interface, as shown in the following figure: 230 - 231 231 (% style="text-align:center" %) 232 -[[image: 2.png]]231 +[[image:8-1Recipe.png]] 233 233 233 +Click [Add] to pop up the recipe setting interface, as shown in the following figure: 234 + 234 234 |Recipe configuration options|Description|Notice 235 235 |Recipe name|Name the current recipe|Note: Recipe name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters. 236 236 |Group number|Configure the group number of the current recipe, ranging from 0 to 1000| ... ... @@ -274,9 +274,6 @@ 274 274 275 275 **Description** 276 276 277 -(% style="text-align:center" %) 278 -[[image:8-1Recipe.png]] 279 - 280 280 **Basic** 281 281 282 282 * **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object); ... ... @@ -462,17 +462,21 @@ 462 462 * When the elements of a line in CSV file is more than the elements set in the software (DB), it will prompt the import failure; 463 463 * When the CSV file imported into the regular series HMI is a recipe file, the data representing the recipe format (elements, number of groups, whether it is a special recipe) in line 1 must be correct, otherwise the import of CSV file will fail. 464 464 465 -= =**Reciperecord function** ==463 += **New recipe ** = 466 466 467 -**Basic setting** 465 +(% class="box infomessage" %) 466 +((( 467 +Note: The recipe is available for the ig and RH series, starting from software version PI9. For other series, please refer to the traditional recipe. 468 +))) 468 468 470 +**General:** 471 + 469 469 (% style="text-align:center" %) 470 -[[image: 3.png]]473 +[[image:AzlSf2dTCpL.png]] 471 471 472 -Recipe select ion: Select the recipe name to be displayed. The list is all the recipes configured in the recipe. If the list is empty, add the recipe in [Recipe].475 +**Recipe select:** Select the recipe name to be displayed. The list is all the recipes configured in the recipe. If the list is empty, add the recipe in [Recipe]. 473 473 474 -Recipe shortcut key setting: 475 - 477 +**Recipe buttons configuration:** 476 476 Add data: Used to add groups. 477 477 478 478 Delete data: Used to delete the selected configuration ... ... @@ -485,34 +485,35 @@ 485 485 486 486 Export recipe: Used to export the current recipe as a file. 487 487 488 -**Graphic** 490 +**Graphic:** 489 489 490 490 (% style="text-align:center" %) 491 -[[image: 4.png]]493 +[[image:AAwnFNTik0dN.png]] 492 492 493 -Style selecti on:Styles can be switched or customized.495 +**Style select:**The basic and custom styles can be selected for the recipe table. Enabling custom styles allows you to configure the table's colors. 494 494 495 -Background configuration: Set the recipe background, including background color and transparency. 497 +**Cell type: **The height and widths of table rows and columns can be customized. 498 +**Security:** 496 496 497 -Table configuration: Set the appearance of recipe table area, including row background color, row spacing color, horizontal header background color, vertical header background color, horizontal header text color, vertical header text color, text color, row selected color, name color, line color and cell style. 498 - 499 -**Expansion** 500 - 501 501 (% style="text-align:center" %) 502 -[[image: 5.png]]501 +[[image:aaa.png]] 503 503 504 -Object lock: With the interlock address, the object is locked and the lock icon is displayed (upper left corner of the object) when the lock address is 0, and the bit switch is operable only when the bit pointed by the interlock bit address is 1. To lock the bit switch when the interlock bit address is 1, just check "Lock in ON". 503 +**Object Lock** 504 +1.Use an interlock bit address; when the address value is 0, the component will be locked and a lock icon will be displayed. The bit switch can only be operated when the bit at the specified address is 1. 505 +2.To hide the lock icon, check the "Do not display lock icon" option. 506 +3.To lock the bit switch when the interlock bit address is 1, simply check the "Lock when ON" option. 507 +4.Check "Display in grayscale" to have text information appear in gray when the component is locked. 508 +**New recipe function address** 505 505 506 -Object lock icon: Icons will not display when the [Not display “Lock” icon] option is checked. Icon display will adapt to the change of object size. 507 - 508 -Gray level display: When the object is locked, the text message will be grayed out. 509 - 510 -== **New recipe function address** == 511 - 512 512 In recipe, new special address is used as Function address. 513 513 514 -**Address Type: **RPG512 +**Address Type:RPG** 515 515 514 +(% class="box infomessage" %) 515 +((( 516 +Note: The new recipe **cannot use the internal function addresses of traditional recipes**; only the new recipe in** PI 11.4** and above can use RPG addresses. 517 +))) 518 + 516 516 (% style="text-align:center" %) 517 517 [[image:企业微信截图_17570533194720.png]] 518 518 ... ... @@ -618,22 +618,22 @@ 618 618 The special addresses used in the Recipe are shown in the following table: 619 619 620 620 (% class="table-bordered" %) 621 -|=Address|=Description|=Function 622 -|HSW1611|Traditional Recipe transfer operation.|((( 624 +|=Address|=(% style="width: 445px;" %)Description|=(% style="width: 629px;" %)Function 625 +|HSW1611|(% style="width:445px" %)Traditional Recipe transfer operation.|(% style="width:629px" %)((( 623 623 ~=1: Recipe download. 624 624 625 625 ~=2: Recipe upload. 626 626 ))) 627 -|HSW1612|Traditional Recipe group number.|Traditional Recipe group number. 630 +|HSW1612|(% style="width:445px" %)Traditional Recipe group number.|(% style="width:629px" %)Traditional Recipe group number. 628 628 |((( 629 629 HSW242 630 -)))|((( 633 +)))|(% style="width:445px" %)((( 631 631 Recipe operation result prompt: 632 632 633 633 Upload: Data is written to recipe file from address. 634 634 635 635 Download: Data is written to the address from recipe file. 636 -)))|((( 639 +)))|(% style="width:629px" %)((( 637 637 ~=1: Recipe download, start. 638 638 639 639 ~=2: Recipe download, execution error. ... ... @@ -648,6 +648,7 @@ 648 648 649 649 ~=12: Recipe upload, successful. 650 650 ))) 654 +|HSW11816|(% style="width:445px" %)Recipe record component button spacing control|(% style="width:629px" %)This controls the spacing between the top and bottom rows of buttons in all recipe record widgets. The value is the pixel spacing between the buttons. The minimum value is 0, and the maximum value is calculated based on the width of each recipe widget. The spacing plus the button size must not exceed the widget's size. (Note that if the register is greater than the maximum value, the actual spacing is the maximum spacing.) 651 651 652 652 == **Recipe index** == 653 653 ... ... @@ -923,15 +923,14 @@ 923 923 (% class="wikigeneratedid" %) 924 924 **Color sequence configuration interface** 925 925 930 +(% style="text-align:center" %) 931 +[[image:2.png]] 926 926 927 927 **Upgrade to Global Configuration: **This color sequence is upgraded to the global default. 928 928 929 929 **Global Configuration:** When a new bar chart control is created in a project, the color sequence has a default configuration. When you upgrade an existing configuration to a global configuration, the default color sequence for the new control will be the same as the configured color sequence. 930 930 931 -(% style="text-align:center" %) 932 -[[image:2.png]] 933 933 934 - 935 935 **Enable Baseline:** Set baselines on the bar chart. 936 936 937 937 **Baseline: **The baseline ID bound to the channel) (click to enter the baseline configuration interface). ... ... @@ -986,19 +986,27 @@ 986 986 :Menu 987 987 988 988 992 + 989 989 :Zoom in 990 990 991 991 992 992 997 + 993 993 :Zoom out 994 994 995 995 996 996 1002 + 997 997 :Restore button (Reset the chart's zoom level to its original 1:1 ratio) 998 998 999 999 1006 + 1007 + 1000 1000 :Data label hide/show button(Controls hiding/showing of data labels) 1001 1001 1010 + 1011 + 1012 + 1002 1002 :Settings Button 1003 1003 1004 1004 ... ... @@ -1386,6 +1386,12 @@ 1386 1386 1387 1387 = **Cloud** = 1388 1388 1400 +(% class="box infomessage" %) 1401 +((( 1402 +**Note:** Regarding to how to download V-net Client in PC or V-net app on the phone, please refer to the following link. 1403 +**Link: [[Download>>https://docs.we-con.com.cn/bin/view/V-Net%202.0/Download/Software/]]** 1404 +))) 1405 + 1389 1389 **Introduction** 1390 1390 1391 1391 You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.) ... ... @@ -1435,7 +1435,7 @@ 1435 1435 1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default. 1436 1436 1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags. 1437 1437 1438 -= MQTT [[image:2.png]]=1455 += MQTT = 1439 1439 1440 1440 (% class="wikigeneratedid" %) 1441 1441 Configurable type MQTT. Users can publish message to the MQTT server or subscribe topics from the MQTT server. ... ... @@ -3045,6 +3045,22 @@ 3045 3045 (% style="text-align:center" %) 3046 3046 [[image:56.jpg]] 3047 3047 3065 +This chapter describes how to use various MQTT communication protocols. Users can publish messages to the MQTT server and subscribe to topics from the server. 3066 + 3067 +Some HMI models support a multi-instance MQTT client architecture, allowing the HMI device to act as a client and connect to multiple independent MQTT Brokers (servers). With this function, messages can be published to different servers without interference. It breaks the limit of a single data channel, supports distributed data reporting, multi-cloud collaboration, and integration of heterogeneous systems, enabling "one-device multi-send" directly on the device side. In addition, different network adapters can be selected to bind data flows and enhance data security. 3068 + 3069 +Each MQTT connection instance supports independent operating status control and complete parameter configurations, ensuring high availability and flexibility of communication in complex network environments. In addition to enabling or disabling each server in project configuration, users can dynamically adjust the communication status of specific channels by operating registers according to service requirements or network conditions, without device restart or interference to other channels. 3070 + 3071 +Click [MQTT] [[image:1788161202460-725.png]]under Function Configuration/Cloud Configuration in the top menu bar of the software. Click the Add button to pop up the setting window, and select different cloud services for MQTT configuration, as shown in the figure below: 3072 + 3073 +[[image:1788161202461-324.png]] 3074 + 3075 +[[image:1788161202466-398.png]] 3076 + 3077 +Enabled: Check this option to enable the connection of the designated server. 3078 + 3079 +Network adapter: Click the button on the right and select a specified network adapter from the drop-down list. If [Default] is selected, the system will automatically use an available network port for connection. Multiple servers can share the same network adapter. 3080 + 3048 3048 = OPCUA Server = 3049 3049 3050 3050 (% class="box infomessage" %)
- 1788160673662-172.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.8 KB - Content
- 1788161202460-725.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.8 KB - Content
- 1788161202461-324.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.6 KB - Content
- 1788161202466-398.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.1 KB - Content
- A06GBxcaxVb.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.4 KB - Content
- AAwnFNTik0dN.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.7 KB - Content
- AlArR7wDAyX.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.0 KB - Content
- AzlSf2dTCpL.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.3 KB - Content
- aaa.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.7 KB - Content
- taavZYE8GK.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +80.4 KB - Content