Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -244,27 +244,47 @@ 244 244 **✎Note: **This function only supported in HMI+, i series, ie series, ig series. 245 245 ))) 246 246 247 - **OperatingProcedures**247 +== Simple recipe == 248 248 249 - *Click"Project"→"BitAlarm"asbelowshows.249 +The recipe function should be used together with the recipe configuration area, file list and record display object. 250 250 251 -(% style="text-align:center" %) 252 -[[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]] 251 +* Click the button [[image:image-20220805170000-1.jpeg]] in "Project"→"Bit Alarm" as below shows. 253 253 254 - * Click "Add" button to open "Recipe" settingwindow.253 +[[image:image-20220805170046-2.jpeg]] 255 255 256 -(% style="text-align:center" %) 257 -[[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]] 255 +* Click "Add" button to open "Recipe" setting window. The recipe mode is divided into simple mode and advanced mode, and you could choose the most suitable mode for configuration according to your needs. The simple mode is as below. 258 258 259 -* Set basic settings for recipe. 260 -* Select mode according to actual condition. 261 -* Other settings can be set according to the actual situation. 262 -* Click "OK“ button to complete settings. 257 +[[image:image-20220805170102-3.jpeg]] 263 263 264 -**Recipe DemoDownloadLink**259 +**Recipe folder: **set the name of the current recipe file. 265 265 266 - [[https:~~/~~/drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]261 +**Group (0~~1000):** Set the recipe group number, the number of elements, the data format. The data format has 8 modes: 16-bit signed decimal, 16-bit unsigned decimal, 16-bit BCD, 32-bit signed decimal, 32-bit unsigned decimal, 16-bit BCD, 32-bit floating point number, 64-bit (double-precision) floating-point number, string, and the choice of data integer and decimal places. 267 267 263 +(% class="box infomessage" %) 264 +((( 265 +✎**Note: **data format is set for the recipe elements, and all the elements in a recipe data format is the same. 266 +))) 267 + 268 +**Mode: **Recipe file is divided into simple mode and advanced mode. Only in advanced mode can exist multiple recipe files used at the same time. (used wiht file list onject), Simple mode can only support a recipe file; Aadvanced mode can insert group information and reordered. 269 + 270 +Function address: all operations are done through function addresses, different operating value is as follows: 271 + 272 +* = 0: no operation; 273 +* = 1: trigger read data; 274 +* = 2: new trigger or update (If there is group number, it updates.) 275 +* = 4: insert (only valid in advanced mode) 276 +* = 8: delete (Delete according to the writing group number. If write and read address are consistent, refer to the reading group number); 277 +* = 16: delete and sorted ((Delete according to the writing group number. If write and read address are consistent, refer to the reading group number) 278 +* = 64: import CSV recipe file. 279 + 280 +Recipe folder names can only consist of (0~~9), (a~~z), (A~~Z), ('_') (''), and other non-English characters. 281 + 282 +Adcanced 283 + 284 +**Recipe Demo Download Link: **[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]] 285 + 286 + 287 + 268 268 = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) = 269 269 270 270 Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC. ... ... @@ -421,7 +421,7 @@ 421 421 422 422 Different from TrendChart, uses need to set history XY curve items in project. Please click "Project"-> "History XY Plot" to open the setting screen. 423 423 424 -Recipe function settings will be display in "[[History XY Plot>>path:http://docs.we-con.com.cn/ wiki/pistudio/view/Helps/06.Objects/#HHistoryXYplot]]" object.444 +Recipe function settings will be display in "[[History XY Plot>>path:https://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HHistoryXYplot]]" object. 425 425 426 426 (% style="text-align:center" %) 427 427 [[image:历史XY 2.png||class="img-thumbnail"]] ... ... @@ -582,17 +582,10 @@ 582 582 * The channel name does not include these 5 special characters: ", ", "| "," <", "> "," & ". 583 583 * The data would be overwritten automatically if the capacity exceed the maximum capacity. For 8000/9000 series, the size of single file cannot exceed 300MB, and total capacity of data records cannot exceed 1000MB. For 3000/3000i/3000ie series, the size of single file cannot exceed 4MB, and total capacity of data records cannot exceed 10MB. If the total amount exceeds the range , an error will be prompted when the project is compiled. 584 584 585 -You could click here to jump to object "[[Data Record Display>>http://docs.we-con.com.cn/ wiki/pistudio/view/Helps/06.Objects/#HDataRecordDisplay]]"605 +You could click here to jump to object "[[Data Record Display>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]" 586 586 587 -(% class="wikigeneratedid" id="H" %) 588 -**PI Data Record Demo Download** 607 += **User permission** = 589 589 590 -**[[Demo Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 591 - 592 -**[[Video Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 593 - 594 -= **{{id name="_Toc3497"/}}{{id name="_User_Permission"/}}User Permission** = 595 - 596 596 **Introduction** 597 597 598 598 1. User permission is one of expansion function in PI Series HMI; it provides multi-level of permission for control HMI operations. ... ... @@ -600,11 +600,14 @@ 600 600 1. Operating record: it records user operations information, the records files are saved in HMI flash; its path is [~\~\flash~\~\UserOperationLogs.db]. 601 601 1. When it is on simulator mode, the files are saved in C disk, its path is [C:~\~\WECON\UserMgrFile\UserOperationLogs.db]. 602 602 616 +(% class="box infomessage" %) 617 +((( 603 603 ✎**Note: **The user name and password must be unique. 619 +))) 604 604 605 -== **Settings**==621 +== Settings == 606 606 607 - **Open PIStudio software, then operate as the following figure.**623 +Open PIStudio software, then operate as the following figure. 608 608 609 609 (% style="text-align:center" %) 610 610 [[image:用户权限 1.png||class="img-thumbnail"]] ... ... @@ -623,25 +623,26 @@ 623 623 * When the configured file does not have the administrator account, a new user can be added through "Funtion address" and set as the administrator. 624 624 * If you select hidden fucntion when configuring user account, the account would display as "~*~*~*~*~*~*" in the list. You only need to enter the password of the corresponding hidden user to log in. 625 625 626 -== **Object permission configuration**==642 +== Object permission configuration == 627 627 628 628 (% style="text-align:center" %) 629 629 [[image:用户权限 2.png||class="img-thumbnail"]] 630 630 631 - {{id name="OLE_LINK3"/}}{{id name="OLE_LINK4"/}}**Operation Procedure of Object Permission**647 +**Operation Procedure of Object Permission** 632 632 633 633 1. Open the object setting windows; 634 -1. Select [Security]windows;635 -1. Check the [User Permission];636 -1. Select [Level]to set permission level;637 -1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded;638 -1. Select the ~[[[Access Denied Setting>>path:#_Security]]]mode;650 +1. Select "Security" windows; 651 +1. Check the "User Permission"; 652 +1. Select "Level" to set permission level; 653 +1. Enter "Log Message", it is for operation records, if it was empty, the operation for this object would be not be recorded; 654 +1. Select the "Access Denied Setting" mode; 639 639 640 640 **Log information description** 641 641 642 -1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 643 -1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. 658 +A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 644 644 660 +The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. 661 + 645 645 The data format are as follows. 646 646 647 647 (% class="table-bordered" %) ... ... @@ -657,8 +657,7 @@ 657 657 |W|Single word 658 658 |D|Double word 659 659 660 -(% start="3" %) 661 -1. Examples. 677 +Examples. 662 662 663 663 * Unsigned decimal, BCD, 32-bit float and Signed decimal are as follows. 664 664 ... ... @@ -781,7 +781,7 @@ 781 781 782 782 [[https:~~/~~/drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq>>url:https://drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq]] 783 783 784 -= **{{id name="_Toc29015"/}}{{id name="_MessagePrompt"/}}MessagePrompt**=800 += Message prompt = 785 785 786 786 A message box is a window used to show some prompts or warnings to users. For example, the application process a task in the process of pop-up message box, suggesting that "U disk has been detected", then the customer can carry out data dump function. 787 787 ... ... @@ -848,12 +848,10 @@ 848 848 849 849 For example: 850 850 851 -~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100. 867 +* In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100. 868 +* For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 869 +* For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 852 852 853 -2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 854 - 855 -3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 856 - 857 857 **(2) Server Selection** 858 858 859 859 **Server**: China, ASEAN, and Europe.
- image-20220805170000-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 KB - Content
- image-20220805170046-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.5 KB - Content
- image-20220805170102-3.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.3 KB - Content
- image-20220805170147-4.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.3 KB - Content
- image-20220805170232-5.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.3 KB - Content