Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
From version 2.1
edited by Joey
on 2022/06/16 13:58
on 2022/06/16 13:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Joey1 +XWiki.Stone - Content
-
... ... @@ -1,9 +1,9 @@ 1 1 (% class="wikigeneratedid" id="H8BasicFunction" %) 2 -This chapter provides information about basic functions and config iration in PIStudio.2 +This chapter provides information about basic functions and configuration in PIStudio. 3 3 4 4 = **{{id name="_Toc28532"/}}Alarm** = 5 5 6 -== **Bit Alarm** ==6 +== **Bit alarm** == 7 7 8 8 Click "Project"->"Bit alarm", it is displayed as the following figure. 9 9 ... ... @@ -18,7 +18,7 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud a and it is alarm data. (Only ig supported)21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 22 22 23 23 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 24 24 ... ... @@ -37,7 +37,7 @@ 37 37 38 38 **✎Note:** 39 39 40 -* If the "cloud" function is enabled and "upload to cloud" is checked, the commun nication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally.40 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 41 41 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 42 42 43 43 **Operating Procedures of Adding One Alarm** ... ... @@ -64,7 +64,7 @@ 64 64 65 65 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 66 66 67 -Click "P orject"->"Word alarm", it is displayed as the following figure.67 +Click "Project"->"Word alarm", it is displayed as the following figure. 68 68 69 69 (% style="text-align:center" %) 70 70 [[image:字报警 1.png||class="img-thumbnail"]] ... ... @@ -77,11 +77,11 @@ 77 77 78 78 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 79 79 80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud a and it is alarm data. (Only ig supported)80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 81 81 82 82 **✎Note:** 83 83 84 -* If the "cloud" function is enabled and "upload to cloud" is checked, the commun nication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.84 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 85 85 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 86 86 87 87 **(6) Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. ... ... @@ -150,7 +150,7 @@ 150 150 151 151 The maximum number of group in recipe is 1000, and the maximum number of member in each group is 1500. 152 152 153 -Recipe could store the data in USB flash disk and SD card and view the recipe data by ob ejct "Recipe display". It has two mode: simple mode and advanced mode.153 +Recipe could store the data in USB flash disk and SD card and view the recipe data by object "Recipe display". It has two mode: simple mode and advanced mode. 154 154 155 155 1. **Simple: **Only support the data operation of one recipe file, including read and write. 156 156 1. **Advanced:** Support the data operation of multiple recipe files, including read, write, insert and index. View and select recipe file by object "File list". ... ... @@ -273,9 +273,9 @@ 273 273 274 274 == **Recipe display** == 275 275 276 -Select the file type "Traditional recipe file" in o nject "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.276 +Select the file type "Traditional recipe file" in object "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line. 277 277 278 -**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as foll woing shown:278 +**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as following shown: 279 279 280 280 (% style="text-align:center" %) 281 281 [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]] ... ... @@ -366,7 +366,7 @@ 366 366 367 367 **(1) Basic settings** 368 368 369 -1. **Curve NO.: **It is for setting curvenumber, 369 +1. **Curve NO.: **It is for setting curve number, 370 370 1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes. 371 371 1. **Curve (1~~8):** It is for setting the number of curves. The default is 3. 372 372 1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves. ... ... @@ -373,7 +373,7 @@ 373 373 374 374 **(2) Sample Type** 375 375 376 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.376 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit. 377 377 1. **Sample unit:** 100ms. 378 378 379 379 **(3) Quick Setting** ... ... @@ -384,7 +384,7 @@ 384 384 [[image:趋势图设置 3.png||class="img-thumbnail"]] 385 385 386 386 (% start="2" %) 387 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 387 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 388 388 389 389 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 390 390 ... ... @@ -408,7 +408,7 @@ 408 408 409 409 **(1) Basic settings** 410 410 411 -1. **Curve NO.: **It is for setting curvenumber, 411 +1. **Curve NO.: **It is for setting curve number, 412 412 1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes. 413 413 1. **Curve (1~~8):** It is for setting the number of curves. The default is 3. 414 414 1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves. ... ... @@ -415,7 +415,7 @@ 415 415 416 416 **(2) Sample Type** 417 417 418 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.418 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit. 419 419 1. **Sample unit:** 100ms. 420 420 421 421 **(3) Quick Setting** ... ... @@ -423,10 +423,10 @@ 423 423 1. **Data format: **It is for setting all the curves, select the data format for all curves, and setting the reading addresses for curves. There are as follows. 424 424 425 425 (% style="text-align:center" %) 426 -[[image: http://docs.we-con.com.cn/wiki/pistudio/download/Helps/08.Basic%20Function/WebHome/%E8%B6%8B%E5%8A%BF%E5%9B%BE%E8%AE%BE%E7%BD%AE%203.png?rev=1.1||alt="趋势图设置 3.png" class="img-thumbnail"]]426 +[[image:image-20220616145435-1.png]] 427 427 428 428 (% start="2" %) 429 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 429 +1. **Sample address: **Fill in the start address that read the device data. If the sample address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 430 430 431 431 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 432 432 ... ... @@ -463,7 +463,7 @@ 463 463 464 464 The data record stored in SD card is also organized according to the above figure. 465 465 466 -The sample time and save time is consistent in the same recor ed group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.466 +The sample time and save time is consistent in the same record group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address. 467 467 468 468 **Sampling interval: **The interval between two consecutive samples was recorded. 469 469 ... ... @@ -511,7 +511,7 @@ 511 511 1. **Trigger to record by sample cycle: **Data will be recorded in every same time, when trigger control bit set ON. 512 512 1. **Trigger to record once and reset: **Data will be recorded when trigger control bit set ON, and the bit will be reset automatically. 513 513 1. **Trigger to record once: **Data will be recorded when trigger control bit set ON, and the bit need to be reset manually. 514 -1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycl ce for trigger sampling address is 1s.514 +1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycle for trigger sampling address is 1s. 515 515 516 516 **(3) Total channels (1~~100): **Set the numbers of channels. Click "apply" to view the channel lists on the right record channel. 517 517 ... ... @@ -527,8 +527,8 @@ 527 527 528 528 **(7) Quick Settings** 529 529 530 -1. **Start Channel:** It sets the continuous addressesfor channels. 531 -1. **Data Format: **It setsthe samedata format for channels. 530 +1. **Start Channel:** It sets the continuous addresses for channels. 531 +1. **Data Format: **It sets the same data format for channels. 532 532 1. **Number of Digits:** It sets the digits’ number for channels. 533 533 1. **Language Settings**: The text in HMI can be in 8 languages, user can set language in here. 534 534 ... ... @@ -570,7 +570,7 @@ 570 570 [[image:用户权限 1.png||class="img-thumbnail"]] 571 571 572 572 1. Click "User Permission" in "Data Tool" toolbar. 573 -1. Edit user name, click "User0" cellunder "UserName", and then enter the user name, one project allows maximum 20 users. 573 +1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users. 574 574 1. Edit password, click "User0" cell under "PassWord", and then enter the user name. 575 575 1. Edit description, click "User0" cell under "Desc", and then enter, description is not necessary。 576 576 1. Check the groups for each user, there are 11 groups beside admin. ... ... @@ -597,7 +597,7 @@ 597 597 1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded; 598 598 1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode; 599 599 600 -**Log i mformation description**600 +**Log information description** 601 601 602 602 1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 603 603 1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. ... ... @@ -762,7 +762,7 @@ 762 762 763 763 **For Example:** 764 764 765 -Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message. 765 +Trigger address is 011, during inserting a USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message. 766 766 767 767 1. **Show message: **Check it to display message when HMI is running. It is checked by default. 768 768 1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default. ... ... @@ -781,7 +781,7 @@ 781 781 782 782 * If you do not want this prompt during the running of HMI, please uncheck "Show message". 783 783 * "Reload text" function would be invalid after clicking "save". 784 -* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&". 784 +* These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&". 785 785 786 786 = **Cloud (Only ig series)** = 787 787
- image-20220616145435-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Joey - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.6 KB - Content