Changes for page 06 Data Tool

Last modified by Jett on 2025/02/18 16:43

From version 21.1
edited by Stone Wu
on 2022/08/05 11:10
Change comment: There is no comment for this version
To version 19.1
edited by Hunter
on 2022/07/29 14:59
Change comment: Renamed from xwiki:PIStudio.1 User Manual.08\.Basic Function.WebHome

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -PIStudio.WebHome
1 +PIStudio.1 User Manual.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Hunter
Content
... ... @@ -3,21 +3,22 @@
3 3  
4 4  = **Alarm** =
5 5  
6 -== Bit alarm ==
6 +== **Bit Alarm** ==
7 7  
8 -Click "Project""Bit Alarm", it is displayed as the following figure.
8 +Click "Project"->"Bit Alarm", it is displayed as the following figure.
9 9  
10 10  (% style="text-align:center" %)
11 11  [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]]
12 12  
13 -**Group No.: **Group number of Bit alarm. The name is unique and cannot be duplicated.
13 +**(1) Group No.: **Group number of Bit alarm. The name is unique and cannot be duplicated.
14 14  
15 -**Bit Address: **Bit address of alarm monitoring
15 +**(2) Bit Address: **Bit address of alarm monitoring
16 16  
17 -* **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
18 -* **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
17 +(% start="1" %)
18 +1. **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
19 +1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
19 19  
20 -**Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
21 21  
22 22  **✎Note:**
23 23  
... ... @@ -31,20 +31,20 @@
31 31  |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
32 32  |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
33 33  
34 -**Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
35 +**(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
35 35  
36 -**Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
37 +**(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
37 37  
38 -**Beep when alarm ON: **The beep works when the alarm is triggered. If "beep once" is checked, bit address alarm only beep once and stop.
39 +**(6) Beep when alarm ON: **The beep works when the alarm is triggered. If "beep once" is checked, bit address alarm only beep once and stop.
39 39  
40 -**Content: **It is used for setting alarm content (command).
41 +**(7) Content: **It is used for setting alarm content (command).
41 41  
42 -**Alarm Screen: **Pop-up alarm screen (it need to be sub-screen);
43 +**(8) Alarm Screen: **Pop-up alarm screen (it need to be sub-screen);
43 43  
44 -* **Position: **The location of the screen alarm display.
45 -* **Pop-up Interval: **The time of reopen the alarm screen when alarm screen closed.
46 -* **Pop-up once: **Pop up alarm screen once, and the screen would not pop up again
47 -* **Close window when alarm off: **Automatically close the alarm screen when alarm off.
45 +1. **Position: **The location of the screen alarm display.
46 +1. **Pop-up Interval: **The time of reopen the alarm screen when alarm screen closed.
47 +1. **Pop-up once: **Pop up alarm screen once, and the screen would not pop up again
48 +1. **Close window when alarm off: **Automatically close the alarm screen when alarm off.
48 48  
49 49  **✎Note:**
50 50  
... ... @@ -53,40 +53,42 @@
53 53  
54 54  **Operating Procedures of Adding One Alarm**
55 55  
56 -* Click "Project""Bit Alarm" as below shows.
57 +1. Click "Project"->"Bit Alarm" as below shows.
57 57  
58 58  (% style="text-align:center" %)
59 59  [[image:8.Basic Function_html_5f8da20315334bac.png||data-xwiki-image-style-alignment="center" height="144" width="539" class="img-thumbnail"]]
60 60  
61 -* Click "Add" button to open "Bit Alarm" setting window.
62 +(% start="2" %)
63 +1. Click "Add" button to open "Bit Alarm" setting window.
62 62  
63 63  (% style="text-align:center" %)
64 64  [[image:8.Basic Function_html_94a019683b506e15.png||data-xwiki-image-style-alignment="center" height="307" width="554" class="img-thumbnail"]]
65 65  
66 -* Set "Bit Address".
67 -* Set "Alarm Condition".
68 -* Set "Content".
69 -* Other settings can be set according to the actual situation".
70 -* Click "OK" button to complete settings.
68 +(% start="3" %)
69 +1. Set "Bit Address".
70 +1. Set "Alarm Condition".
71 +1. Set "Content".
72 +1. Other settings can be set according to the actual situation".
73 +1. Click "OK" button to complete settings.
71 71  
72 -== Word alarm ==
75 +== **Word Alarm** ==
73 73  
74 74  Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated.
75 75  
76 -Click "Project""Word alarm", it is displayed as the following figure.
79 +Click "Project"->"Word alarm", it is displayed as the following figure.
77 77  
78 78  (% style="text-align:center" %)
79 79  [[image:字报警 1.png||class="img-thumbnail"]]
80 80  
81 -**Alarm Name:** You can set alarm name for it. Alarm Name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters.
84 +**(1) Alarm Name:** You can set alarm name for it. Alarm Name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters.
82 82  
83 -**Alarm Address: **It is used for setting word address for word alarm, such as HDW0.
86 +**(2) Alarm Address: **It is used for setting word address for word alarm, such as HDW0.
84 84  
85 -**Data Format: **16-bit unsigned decimal, 16-bit signed decimal, 16-bit BCD, 32-bit unsigned decimal, 32-bit signed decimal, 32-bit BCD, 32-bit float.
88 +**(3) Data Format: **16-bit unsigned decimal, 16-bit signed decimal, 16-bit BCD, 32-bit unsigned decimal, 32-bit signed decimal, 32-bit BCD, 32-bit float.
86 86  
87 -**Group No.: **Group number of word alarm. The name is unique and cannot be duplicated.
90 +**(4)  Group No.: **Group number of word alarm. The name is unique and cannot be duplicated.
88 88  
89 -**Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
92 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
90 90  
91 91  **✎Note:**
92 92  
... ... @@ -100,11 +100,11 @@
100 100  |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
101 101  |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
102 102  
103 -**Record alarm:**  Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location.
106 +**(6) Record alarm:**  Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location.
104 104  
105 -**Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
108 +**(7) Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
106 106  
107 -**Alarm Condition**: Alarm is triggered when designated address meets the alarm condition, it provides four conditions;
110 +**(8) Alarm Condition**: Alarm is triggered when designated address meets the alarm condition, it provides four conditions;
108 108  
109 109  1. **High alarm:** Alarm is triggered when it reaches high limit. It can be a constant or a variable
110 110  1. **Low alarm:** Alarm is triggered when it reaches low limit. It can be a constant or a variable
... ... @@ -111,11 +111,11 @@
111 111  1. **Range alarm:** Alarm is triggered when it exceeds the range. It can be a constant or a variable
112 112  1. **Equivalent alarm: **Alarm is triggered when the value equals to the given data. It can be a constant or a variable
113 113  
114 -**Alarm Info: **It is used for setting alarm content (command);
117 +**(9) Alarm Info: **It is used for setting alarm content (command);
115 115  
116 -**Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
119 +**(10) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
117 117  
118 -**Alarm Screen: **Pop-up alarm screen (it need to be sub-screen);
121 +**(11) Alarm Screen: **Pop-up alarm screen (it need to be sub-screen);
119 119  
120 120  1. **Position: **The location of the screen alarm display.
121 121  1. **Pop-up Interval: **The time of reopen the alarm screen when alarm screen closed.
... ... @@ -122,36 +122,38 @@
122 122  1. **Pop-up once: **Pop up alarm screen once.
123 123  1. **Close window when alarm off: **Automatically close the alarm screen when alarm off.
124 124  
125 -**Beep when alarm ON: **beep works when the alarm is triggered, in the default mode, the beep works until the alarm is released.
128 +**(12) Beep when alarm ON: **beep works when the alarm is triggered, in the default mode, the beep works until the alarm is released.
126 126  
127 -**Beep once:** Beep works once, when alarm is triggered.
130 +**(13) Beep once:** Beep works once, when alarm is triggered.
128 128  
129 -**Alarm List**
132 +**(14) Alarm List**
130 130  
131 131  It displays all the word alarm lists; it will show the alarm information;
132 132  
133 133  **Operating Procedures of Adding One Alarm**
134 134  
135 -* Click "Project" "Word Alarm" as below shows.
138 +1. Click "Project"-> "Word Alarm" as below shows.
136 136  
137 137  (% style="text-align:center" %)
138 138  [[image:8.Basic Function_html_1b59522c984cd7c2.png||height="144" width="492" class="img-thumbnail"]]
139 139  
140 -* Click "AddClick" button to open "Word Alarm" setting window.
143 +(% start="2" %)
144 +1. Click [Add] button to open [Word Alarm] setting window.
141 141  
142 142  (% style="text-align:center" %)
143 143  [[image:8.Basic Function_html_942107c81fc6901c.png||height="307" width="554" class="img-thumbnail"]]
144 144  
145 -* Set Basic information of word alarm.
146 -* Set "Content".
147 -* Other settings can be set according to the actual situation.
148 -* Click "OK" button to complete settings.
149 +(% start="3" %)
150 +1. Set Basic information of word alarm.
151 +1. Set "Content".
152 +1. Other settings can be set according to the actual situation.
153 +1. Click "OK" button to complete settings.
149 149  
150 150  **HMI Alarm Demo Download Link**
151 151  
152 152  [[https:~~/~~/drive.google.com/open?id=1Llq03CMISM_1mMIfU308hxFbs4rGdQGP>>url:https://drive.google.com/open?id=1Llq03CMISM_1mMIfU308hxFbs4rGdQGP]]
153 153  
154 -= **Recipe** =
159 += **{{id name="_Toc17174"/}}{{id name="_Recipe"/}}Recipe** =
155 155  
156 156  Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.
157 157  
... ... @@ -176,20 +176,23 @@
176 176  (% style="text-align:center" %)
177 177  [[image:8-1Recipe.png]]
178 178  
179 -**Basic**
184 +**(1) Basic**
180 180  
181 -* **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object);
182 -** **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters;
183 -* **Group: **It sets the groups' initial number of recipe;
184 -* **Elements:** It sets members' initial number of each group;
185 -* **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form;
186 -* **Decimal: **It sets integer and scale digits;
186 +1. **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object);
187 187  
188 -**Mode Selection**
188 +* **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters;
189 189  
190 +(% start="2" %)
191 +1. **Group: **It sets the groups' initial number of recipe;
192 +1. **Elements:** It sets members' initial number of each group;
193 +1. **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form;
194 +1. **Decimal: **It sets integer and scale digits;
195 +
196 +**(2) Mode Selection**
197 +
190 190  Users could select Simple or Advanced mode.
191 191  
192 -**Function Address:**
200 +**(3) Function Address:**
193 193  
194 194  All the operations for recipe is by this address
195 195  
... ... @@ -200,83 +200,77 @@
200 200  * =8 Delete.
201 201  * =16 Delete and Sequence.
202 202  
203 -**Use Multiple File**
211 +**(4) Use Multiple File**
204 204  
205 205  Check it to use more than one recipe file in HMI, but this option only valid in [Advanced mode];
206 206  
207 -**Select language**
215 +**(5) Select language**
208 208  
209 209  The text in HMI can be in 8 languages, user can set language in here;
210 210  
211 -**Address**
219 +**(6) Address**
212 212  
213 213  1. **Group:** This address is for selecting group number;
214 214  1. **Start: **This is starting address is for reading and writing in recipe, PIStudio will automatically assigns addresses for each members;
215 215  1. **File(16 words): **This address only available when enable the Use Multiple File. This setting address is for input the recipe file's filename.
216 216  
217 -**Use Index**
225 +**(7) Use Index**
218 218  
219 219  If the value from Group address is changed, Read address will display the new data according to new group number immediately. Relatively, if the data of write address is changed, the corresponding group from table is also changed.
220 220  
221 -**Query by Element**
229 +**(8) Query by Element**
222 222  
223 223  Enable it for querying group by specify element, select a primary key from all the elements, except the group number. This element value from all groups must be unique if want to set as primary key;
224 224  
225 -(% class="box infomessage" %)
226 -(((
227 227  **✎Note: **When this option is enabled, Group address will be invalid.
228 -)))
229 229  
230 -**Use Independent Write Address**
235 +**(9) Use Independent Write Address**
231 231  
232 232  To separate Recipe read address and write address.
233 233  
234 -**Use Insert**
239 +**(10) Use Insert**
235 235  
236 236  It inserts data into the specified group, if the specified group already exists, it would not cover the original data, while it will move the original group next one after it.
237 237  
238 -**Discontinuous Address**
243 +**(11) Discontinuous Address**
239 239  
240 240  Whether enable the non-consecutive recipe operation addresses or not. If disabled, the recipe address will recover as the continuous addresses.
241 241  
242 -(% class="box infomessage" %)
243 -(((
244 244  **✎Note: **This function only supported in HMI+, i series, ie series, ig series.
245 -)))
246 246  
247 247  **Operating Procedures**
248 248  
249 -* Click "Project""Bit Alarm" as below shows.
251 +1) Click "Project"->"Bit Alarm" as below shows.
250 250  
251 251  (% style="text-align:center" %)
252 252  [[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]]
253 253  
254 -* Click "Add" button to open "Recipe" setting window.
256 +2) Click "Add" button to open "Recipe" setting window.
255 255  
256 256  (% style="text-align:center" %)
257 257  [[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]]
258 258  
259 -* Set basic settings for recipe.
260 -* Select mode according to actual condition.
261 -* Other settings can be set according to the actual situation.
262 -* Click "OK“ button to complete settings.
261 +3) Set basic settings for recipe.
263 263  
263 +4) Select mode according to actual condition.
264 +
265 +5) Other settings can be set according to the actual situation.
266 +
267 +6) Click [OK] button to complete settings.
268 +
264 264  **Recipe Demo Download Link**
265 265  
266 266  [[https:~~/~~/drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]
267 267  
268 -= (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) =
273 += (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional Recipe**(%%) =
269 269  
270 270  Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.
271 271  
272 272  Traditional recipe function is valid only when the LEVI project is converted to the PI project, and the original project uses the traditional recipe.
273 273  
274 -(% class="box infomessage" %)
275 -(((
276 276  **✎Note**: Currently, only HMI+, i series, ie series, and ig series support the traditional recipe.
277 -)))
278 278  
279 -== Simple recipe mode ==
281 +== **Simple recipe mode** ==
280 280  
281 281  Click the "Traditional Recipe" [[image:8-2TraditionalRecipe.png]] in the "Data tool" bar in the upper side of the software, and the following interface will pop up:
282 282  
... ... @@ -288,19 +288,16 @@
288 288  * The recipe folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), ('').
289 289  * The element name of the recipe cannot include following 5 special characters: " **,** " , " **|** " , " **<** " , " **>** " , " **&** " .
290 290  
291 -== Recipe display ==
293 +== **Recipe display** ==
292 292  
293 293  Select the file type "Traditional recipe file" in object "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.
294 294  
295 -(% class="box infomessage" %)
296 -(((
297 297  **✎Note**: The Recipe Display can display up to 50 groups of 100 elements by default, which can be to display out of range by enabled "Address Control". After the "Address Control" is enabled, the display group number can be reached to 100. If want to display more than 100, please adjust the "Start Group" from "Address Control" to index the display group, as following shown:
298 -)))
299 299  
300 300  (% style="text-align:center" %)
301 301  [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]]
302 302  
303 -== Recipe transmission address ==
302 +== **Recipe transmission address** ==
304 304  
305 305  The special addresses used in the Recipe are shown in the following table:
306 306  
... ... @@ -351,26 +351,26 @@
351 351  1. The RPW register only supports word address access.
352 352  1. It can be known from the coding method of RPW~*~*~#~#~#~# that the range of RPW is from RPW000000-RPW990450, wherein the range of group number is 0-100, and the range of element is 0-450.
353 353  
354 -== Recipe example ==
353 +== **Recipe example** ==
355 355  
356 356  The recipe index makes the modification and display of recipe data more convenient. Only need to modify and display the data of the recipe file through "Numeric Input/Display" Object and "Word Switch".
357 357  
358 -Edit the recipe configuration, create three groups of recipes, 4 elements for per group: Red, green, blue, spraying time, as following shown:
357 +(1) Edit the recipe configuration, create three groups of recipes, 4 elements for per group: Red, green, blue, spraying time, as following shown:
359 359  
360 360  (% style="text-align:center" %)
361 361  [[image:8-5TraditionalRecipeCaseConfig.png]]
362 362  
363 -RPW 0~~3 can display the data of group for the selected line. RPW10000~~10003, RPW20000~~20003, RPW30000~~30003 each address can display the single element. Directly modify the content of the RPW address and then modify the recipe data, as following shown:
362 +(2) RPW 0~~3 can display the data of group for the selected line. RPW10000~~10003, RPW20000~~20003, RPW30000~~30003 each address can display the single element. Directly modify the content of the RPW address and then modify the recipe data, as following shown:
364 364  
365 365  (% style="text-align:center" %)
366 366  [[image:8-7TraditionalRecipeCaseShowNoOpera.png]]
367 367  
368 -After selecting the 2nd group, trigger the download button to download the whole group data to the corresponding element address (For this case, the data will write into HDW0~~3), or trigger the upload button to upload the content of the element address to the specified recipe group.
367 +(3) After selecting the 2nd group, trigger the download button to download the whole group data to the corresponding element address (For this case, the data will write into HDW0~~3), or trigger the upload button to upload the content of the element address to the specified recipe group.
369 369  
370 370  (% style="text-align:center" %)
371 371  [[image:8-6TraditionalRecipeCaseShow.png]]
372 372  
373 -= **Trend chart** =
372 += **{{id name="_Toc5565"/}}{{id name="_Trend_Chart"/}}Trend Chart** =
374 374  
375 375  Trend chart function is used for displaying the real-time data in HMI as curve graph, which X axis represent as time, Y axis represent as data.
376 376  
... ... @@ -408,20 +408,17 @@
408 408  
409 409  **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content.
410 410  
411 -(% class="box infomessage" %)
412 -(((
413 413  **✎Note: **Curve names can only consist of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_') (' '), and other non-English characters.
414 -)))
415 415  
416 416  **Trend Chart Demo Download Link**
417 417  
418 418  [[https:~~/~~/drive.google.com/open?id=1smnaAvSxOWC0WQK4_uvqHXWn4vUZxGJC>>url:https://drive.google.com/open?id=1smnaAvSxOWC0WQK4_uvqHXWn4vUZxGJC]]
419 419  
420 -= **History XY plot** =
416 += **{{id name="_Toc7121"/}}{{id name="_History_XY_Plot"/}}History XY Plot** =
421 421  
422 422  Different from TrendChart, uses need to set history XY curve items in project. Please click "Project"-> "History XY Plot" to open the setting screen.
423 423  
424 -Recipe function settings will be display in "[[History XY Plot>>path:https://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HHistoryXYplot]]" object.
420 +Recipe function settings will be display in "[[History XY Plot>>path:http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HHistoryXYplot]]" object.
425 425  
426 426  (% style="text-align:center" %)
427 427  [[image:历史XY 2.png||class="img-thumbnail"]]
... ... @@ -453,31 +453,29 @@
453 453  
454 454  **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content.
455 455  
456 -(% class="box infomessage" %)
457 -(((
458 458  **✎Note: **Curve names can only consist of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_') (' '), and other non-English characters.
459 -)))
460 460  
461 461  **Operating Procedure**
462 462  
463 -* Click "Project" "History XY Plot" to open the function selecting windows.
456 +1. Click "Project" -> "History XY Plot" to open the function selecting windows.
464 464  
465 465  (% style="text-align:center" %)
466 466  [[image:8.Basic Function_html_5da6ca44bd28acbe.png||height="144" width="533" class="img-thumbnail"]]
467 467  
468 -* Click "Add" button to open "History XY Plot” setting windows.
461 +(% start="2" %)
462 +1. Click "Add" button to open [History XY Plot] setting windows.
469 469  
470 470  (% style="text-align:center" %)
471 471  [[image:8.Basic Function_html_6345b50ea55168fa.png||height="307" width="554" class="img-thumbnail"]]
472 472  
473 -* Setting the function of History XY Plot.
474 -* Click "OK" to save the setting.
467 +1. Setting the function of History XY Plot.
468 +1. Click "OK" to save the setting.
475 475  
476 476  **Download Link**
477 477  
478 478  [[https:~~/~~/drive.google.com/open?id=1t4_HuRmIJJ-B5ryA2kVMadD9FywKhZ4r>>url:https://drive.google.com/open?id=1t4_HuRmIJJ-B5ryA2kVMadD9FywKhZ4r]]
479 479  
480 -= (% style="color:inherit; font-family:inherit; font-size:29px" %)**Data record**(%%) =
474 += (% style="color:inherit; font-family:inherit; font-size:29px" %)**Data Record**(%%) =
481 481  
482 482  The data record function is organized according to the structure below. In a project, there can be multiple record groups, each record group containing multiple channels. Different groups have different sampling times.
483 483  
... ... @@ -498,9 +498,9 @@
498 498  
499 499  ✎**Note: **
500 500  
501 -After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Data record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
495 +1) After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Data record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
502 502  
503 -The number of Data records upload to Cloud shall not exceed the limit value, or the sum of the imported Data records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
497 +2) The number of Data records upload to Cloud shall not exceed the limit value, or the sum of the imported Data records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
504 504  
505 505  (% style="margin-left:auto; margin-right:auto; width:513px" %)
506 506  |=(% style="width: 70px;" %)Series|=(% style="width: 442px;" %)Number of Data Record upload to Cloud
... ... @@ -509,10 +509,11 @@
509 509  |(% style="width:70px" %)3000ig|(% style="text-align:center; width:442px" %)50
510 510  |(% style="width:70px" %)8000ig|(% style="text-align:center; width:442px" %)100
511 511  
512 -The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.
506 +3) The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.
513 513  
514 -Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ".
508 +4) Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ".
515 515  
510 +
516 516  (% class="wikigeneratedid" id="HSettings" %)
517 517  **Settings**
518 518  
... ... @@ -582,10 +582,17 @@
582 582  * The channel name does not include these 5 special characters: ", ", "| "," <", "> "," & ".
583 583  * The data would be overwritten automatically if the capacity exceed the maximum capacity. For 8000/9000 series, the size of single file cannot exceed 300MB, and total capacity of data records cannot exceed 1000MB. For 3000/3000i/3000ie series, the size of single file cannot exceed 4MB, and total capacity of data records cannot exceed 10MB. If the total amount exceeds the range , an error will be prompted when the project is compiled.
584 584  
585 -You could click here to jump to object "[[Data Record Display>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]"
580 +You could click here to jump to object "[[Data Record Display>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HDataRecordDisplay]]"
586 586  
587 -= **User permission** =
582 +(% class="wikigeneratedid" id="H" %)
583 +**PI Data Record Demo Download**
588 588  
585 +**[[Demo Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]**
586 +
587 +**[[Video Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]**
588 +
589 += **{{id name="_Toc3497"/}}{{id name="_User_Permission"/}}User Permission** =
590 +
589 589  **Introduction**
590 590  
591 591  1. User permission is one of expansion function in PI Series HMI; it provides multi-level of permission for control HMI operations.
... ... @@ -593,14 +593,11 @@
593 593  1. Operating record: it records user operations information, the records files are saved in HMI flash; its path is [~\~\flash~\~\UserOperationLogs.db].
594 594  1. When it is on simulator mode, the files are saved in C disk, its path is [C:~\~\WECON\UserMgrFile\UserOperationLogs.db].
595 595  
596 -(% class="box infomessage" %)
597 -(((
598 598  ✎**Note: **The user name and password must be unique.
599 -)))
600 600  
601 -== Settings ==
600 +== **Settings** ==
602 602  
603 -Open PIStudio software, then operate as the following figure.
602 +**Open PIStudio software, then operate as the following figure.**
604 604  
605 605  (% style="text-align:center" %)
606 606  [[image:用户权限 1.png||class="img-thumbnail"]]
... ... @@ -619,26 +619,25 @@
619 619  * When the configured file does not have the administrator account, a new user can be added  through "Funtion address" and set as the administrator.
620 620  * If you select hidden fucntion when configuring user account, the account would display as "~*~*~*~*~*~*" in the list. You only need to enter the password of the corresponding hidden user to log in.
621 621  
622 -== Object permission configuration ==
621 +== **Object permission configuration** ==
623 623  
624 624  (% style="text-align:center" %)
625 625  [[image:用户权限 2.png||class="img-thumbnail"]]
626 626  
627 -**Operation Procedure of Object Permission**
626 +{{id name="OLE_LINK3"/}}{{id name="OLE_LINK4"/}}**Operation Procedure of Object Permission**
628 628  
629 629  1. Open the object setting windows;
630 -1. Select "Security" windows;
631 -1. Check the "User Permission";
632 -1. Select "Level" to set permission level;
633 -1. Enter "Log Message", it is for operation records, if it was empty, the operation for this object would be not be recorded;
634 -1. Select the "Access Denied Setting" mode;
629 +1. Select [Security] windows;
630 +1. Check the [User Permission];
631 +1. Select [Level] to set permission level;
632 +1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded;
633 +1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode;
635 635  
636 636  **Log information description**
637 637  
638 -A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
637 +1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
638 +1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
639 639  
640 -The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
641 -
642 642   The data format are as follows.
643 643  
644 644  (% class="table-bordered" %)
... ... @@ -654,7 +654,8 @@
654 654  |W|Single word
655 655  |D|Double word
656 656  
657 -Examples.
655 +(% start="3" %)
656 +1. Examples.
658 658  
659 659  * Unsigned decimal, BCD, 32-bit float and Signed decimal are as follows.
660 660  
... ... @@ -777,7 +777,7 @@
777 777  
778 778  [[https:~~/~~/drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq>>url:https://drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq]]
779 779  
780 -= Message prompt =
779 += **{{id name="_Toc29015"/}}{{id name="_MessagePrompt"/}}Message Prompt** =
781 781  
782 782  A message box is a window used to show some prompts or warnings to users. For example, the application process a task in the process of pop-up message box, suggesting that "U disk has been detected", then the customer can carry out data dump function.
783 783  
... ... @@ -844,10 +844,12 @@
844 844  
845 845  For example:
846 846  
847 -* In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
848 -* For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
849 -* For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
846 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
850 850  
848 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
849 +
850 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
851 +
851 851  **(2) Server Selection**
852 852  
853 853   **Server**: China, ASEAN, and Europe.