... ... @@ -244,47 +244,27 @@
244 244  **✎Note: **This function only supported in HMI+, i series, ie series, ig series.
245 245  )))
246 246  
247 -== Simple recipe ==
247 +**Operating Procedures**
248 248  
249 -The recipe function should be used together with the recipe configuration area, file list and record display object.
249 +* Click "Project"→"Bit Alarm" as below shows.
250 250  
251 -* Click the button [[image:image-20220805170000-1.jpeg]] in "Project"→"Bit Alarm" as below shows.
251 +(% style="text-align:center" %)
252 +[[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]]
252 252  
253 -[[image:image-20220805170046-2.jpeg]]
254 +* Click "Add" button to open "Recipe" setting window.
254 254  
255 -* Click "Add" button to open "Recipe" setting window. The recipe mode is divided into simple mode and advanced mode, and you could choose the most suitable mode for configuration according to your needs. The simple mode is as below.
256 +(% style="text-align:center" %)
257 +[[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]]
256 256  
257 -[[image:image-20220805170102-3.jpeg]]
259 +* Set basic settings for recipe.
260 +* Select mode according to actual condition.
261 +* Other settings can be set according to the actual situation.
262 +* Click "OK“ button to complete settings.
258 258  
259 -**Recipe folder: **set the name of the current recipe file.
264 +**Recipe Demo Download Link**
260 260  
261 -**Group (0~~1000):** Set the recipe group number, the number of elements, the data format. The data format has 8 modes: 16-bit signed decimal, 16-bit unsigned decimal, 16-bit BCD, 32-bit signed decimal, 32-bit unsigned decimal, 16-bit BCD, 32-bit floating point number, 64-bit (double-precision) floating-point number, string, and the choice of data integer and decimal places.
266 +[[https:~~/~~/drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]
262 262  
263 -(% class="box infomessage" %)
264 -(((
265 -✎**Note: **data format is set for the recipe elements, and all the elements in a recipe data format is the same.
266 -)))
267 -
268 -**Mode: **Recipe file is divided into simple mode and advanced mode. Only in advanced mode can exist multiple recipe files used at the same time. (used wiht file list onject), Simple mode can only support a recipe file; Aadvanced mode can insert group information and reordered.
269 -
270 -Function address: all operations are done through function addresses, different operating value is as follows:
271 -
272 -* = 0: no operation;
273 -* = 1: trigger read data;
274 -* = 2: new trigger or update (If there is group number, it updates.)
275 -* = 4: insert (only valid in advanced mode)
276 -* = 8: delete (Delete according to the writing group number. If write and read address are consistent, refer to the reading group number);
277 -* = 16: delete and sorted ((Delete according to the writing group number. If write and read address are consistent, refer to the reading group number)
278 -* = 64: import CSV recipe file.
279 -
280 -Recipe folder names can only consist of (0~~9), (a~~z), (A~~Z), ('_') (''), and other non-English characters.
281 -
282 -Adcanced
283 -
284 -**Recipe Demo Download Link: **[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]
285 -
286 -
287 -
288 288  = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) =
289 289  
290 290  Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.
... ... @@ -441,7 +441,7 @@
441 441  
442 442  Different from TrendChart, uses need to set history XY curve items in project. Please click "Project"-> "History XY Plot" to open the setting screen.
443 443  
444 -Recipe function settings will be display in "[[History XY Plot>>path:https://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HHistoryXYplot]]" object.
424 +Recipe function settings will be display in "[[History XY Plot>>path:http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HHistoryXYplot]]" object.
445 445  
446 446  (% style="text-align:center" %)
447 447  [[image:历史XY 2.png||class="img-thumbnail"]]
... ... @@ -602,10 +602,17 @@
602 602  * The channel name does not include these 5 special characters: ", ", "| "," <", "> "," & ".
603 603  * The data would be overwritten automatically if the capacity exceed the maximum capacity. For 8000/9000 series, the size of single file cannot exceed 300MB, and total capacity of data records cannot exceed 1000MB. For 3000/3000i/3000ie series, the size of single file cannot exceed 4MB, and total capacity of data records cannot exceed 10MB. If the total amount exceeds the range , an error will be prompted when the project is compiled.
604 604  
605 -You could click here to jump to object "[[Data Record Display>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]"
585 +You could click here to jump to object "[[Data Record Display>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HDataRecordDisplay]]"
606 606  
607 -= **User permission** =
587 +(% class="wikigeneratedid" id="H" %)
588 +**PI Data Record Demo Download**
608 608  
590 +**[[Demo Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]**
591 +
592 +**[[Video Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]**
593 +
594 += **{{id name="_Toc3497"/}}{{id name="_User_Permission"/}}User Permission** =
595 +
609 609  **Introduction**
610 610  
611 611  1. User permission is one of expansion function in PI Series HMI; it provides multi-level of permission for control HMI operations.
... ... @@ -613,14 +613,11 @@
613 613  1. Operating record: it records user operations information, the records files are saved in HMI flash; its path is [~\~\flash~\~\UserOperationLogs.db].
614 614  1. When it is on simulator mode, the files are saved in C disk, its path is [C:~\~\WECON\UserMgrFile\UserOperationLogs.db].
615 615  
616 -(% class="box infomessage" %)
617 -(((
618 618  ✎**Note: **The user name and password must be unique.
619 -)))
620 620  
621 -== Settings ==
605 +== **Settings** ==
622 622  
623 -Open PIStudio software, then operate as the following figure.
607 +**Open PIStudio software, then operate as the following figure.**
624 624  
625 625  (% style="text-align:center" %)
626 626  [[image:用户权限 1.png||class="img-thumbnail"]]
... ... @@ -639,26 +639,25 @@
639 639  * When the configured file does not have the administrator account, a new user can be added  through "Funtion address" and set as the administrator.
640 640  * If you select hidden fucntion when configuring user account, the account would display as "~*~*~*~*~*~*" in the list. You only need to enter the password of the corresponding hidden user to log in.
641 641  
642 -== Object permission configuration ==
626 +== **Object permission configuration** ==
643 643  
644 644  (% style="text-align:center" %)
645 645  [[image:用户权限 2.png||class="img-thumbnail"]]
646 646  
647 -**Operation Procedure of Object Permission**
631 +{{id name="OLE_LINK3"/}}{{id name="OLE_LINK4"/}}**Operation Procedure of Object Permission**
648 648  
649 649  1. Open the object setting windows;
650 -1. Select "Security" windows;
651 -1. Check the "User Permission";
652 -1. Select "Level" to set permission level;
653 -1. Enter "Log Message", it is for operation records, if it was empty, the operation for this object would be not be recorded;
654 -1. Select the "Access Denied Setting" mode;
634 +1. Select [Security] windows;
635 +1. Check the [User Permission];
636 +1. Select [Level] to set permission level;
637 +1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded;
638 +1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode;
655 655  
656 656  **Log information description**
657 657  
658 -A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
642 +1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
643 +1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
659 659  
660 -The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
661 -
662 662   The data format are as follows.
663 663  
664 664  (% class="table-bordered" %)
... ... @@ -674,7 +674,8 @@
674 674  |W|Single word
675 675  |D|Double word
676 676  
677 -Examples.
660 +(% start="3" %)
661 +1. Examples.
678 678  
679 679  * Unsigned decimal, BCD, 32-bit float and Signed decimal are as follows.
680 680  
... ... @@ -797,7 +797,7 @@
797 797  
798 798  [[https:~~/~~/drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq>>url:https://drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq]]
799 799  
800 -= Message prompt =
784 += **{{id name="_Toc29015"/}}{{id name="_MessagePrompt"/}}Message Prompt** =
801 801  
802 802  A message box is a window used to show some prompts or warnings to users. For example, the application process a task in the process of pop-up message box, suggesting that "U disk has been detected", then the customer can carry out data dump function.
803 803  
... ... @@ -864,10 +864,12 @@
864 864  
865 865  For example:
866 866  
867 -* In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
868 -* For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
869 -* For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
851 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
870 870  
853 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
854 +
855 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
856 +
871 871  **(2) Server Selection**
872 872  
873 873   **Server**: China, ASEAN, and Europe.
image-20220805170000-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -1.1 KB
Content
image-20220805170046-2.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -34.5 KB
Content
image-20220805170102-3.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content
image-20220805170147-4.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content
image-20220805170232-5.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content