Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PIStudio.WebHome 1 +PIStudio.1 User Manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Hunter - Content
-
... ... @@ -3,21 +3,22 @@ 3 3 4 4 = **Alarm** = 5 5 6 -== Bit alarm ==6 +== **Bit Alarm** == 7 7 8 -Click "Project" →"Bit Alarm", it is displayed as the following figure.8 +Click "Project"->"Bit Alarm", it is displayed as the following figure. 9 9 10 10 (% style="text-align:center" %) 11 11 [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] 12 12 13 -**Group No.: **Group number of Bit alarm. The name is unique and cannot be duplicated. 13 +**(1) Group No.: **Group number of Bit alarm. The name is unique and cannot be duplicated. 14 14 15 -**Bit Address: **Bit address of alarm monitoring 15 +**(2) Bit Address: **Bit address of alarm monitoring 16 16 17 -* **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 18 -* **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 17 +(% start="1" %) 18 +1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 +1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 19 19 20 -**Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 21 21 22 22 **✎Note:** 23 23 ... ... @@ -31,20 +31,20 @@ 31 31 |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 32 32 |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 33 33 34 -**Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 35 +**(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 35 35 36 -**Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. 37 +**(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. 37 37 38 -**Beep when alarm ON: **The beep works when the alarm is triggered. If "beep once" is checked, bit address alarm only beep once and stop. 39 +**(6) Beep when alarm ON: **The beep works when the alarm is triggered. If "beep once" is checked, bit address alarm only beep once and stop. 39 39 40 -**Content: **It is used for setting alarm content (command). 41 +**(7) Content: **It is used for setting alarm content (command). 41 41 42 -**Alarm Screen: **Pop-up alarm screen (it need to be sub-screen); 43 +**(8) Alarm Screen: **Pop-up alarm screen (it need to be sub-screen); 43 43 44 - ***Position: **The location of the screen alarm display.45 - ***Pop-up Interval: **The time of reopen the alarm screen when alarm screen closed.46 - ***Pop-up once: **Pop up alarm screen once, and the screen would not pop up again47 - ***Close window when alarm off: **Automatically close the alarm screen when alarm off.45 +1. **Position: **The location of the screen alarm display. 46 +1. **Pop-up Interval: **The time of reopen the alarm screen when alarm screen closed. 47 +1. **Pop-up once: **Pop up alarm screen once, and the screen would not pop up again 48 +1. **Close window when alarm off: **Automatically close the alarm screen when alarm off. 48 48 49 49 **✎Note:** 50 50 ... ... @@ -53,40 +53,42 @@ 53 53 54 54 **Operating Procedures of Adding One Alarm** 55 55 56 - *Click "Project"→"Bit Alarm" as below shows.57 +1. Click "Project"->"Bit Alarm" as below shows. 57 57 58 58 (% style="text-align:center" %) 59 59 [[image:8.Basic Function_html_5f8da20315334bac.png||data-xwiki-image-style-alignment="center" height="144" width="539" class="img-thumbnail"]] 60 60 61 -* Click "Add" button to open "Bit Alarm" setting window. 62 +(% start="2" %) 63 +1. Click "Add" button to open "Bit Alarm" setting window. 62 62 63 63 (% style="text-align:center" %) 64 64 [[image:8.Basic Function_html_94a019683b506e15.png||data-xwiki-image-style-alignment="center" height="307" width="554" class="img-thumbnail"]] 65 65 66 -* Set "Bit Address". 67 -* Set "Alarm Condition". 68 -* Set "Content". 69 -* Other settings can be set according to the actual situation". 70 -* Click "OK" button to complete settings. 68 +(% start="3" %) 69 +1. Set "Bit Address". 70 +1. Set "Alarm Condition". 71 +1. Set "Content". 72 +1. Other settings can be set according to the actual situation". 73 +1. Click "OK" button to complete settings. 71 71 72 -== Word alarm ==75 +== **Word Alarm** == 73 73 74 74 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 75 75 76 -Click "Project" →"Word alarm", it is displayed as the following figure.79 +Click "Project"->"Word alarm", it is displayed as the following figure. 77 77 78 78 (% style="text-align:center" %) 79 79 [[image:字报警 1.png||class="img-thumbnail"]] 80 80 81 -**Alarm Name:** You can set alarm name for it. Alarm Name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters. 84 +**(1) Alarm Name:** You can set alarm name for it. Alarm Name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters. 82 82 83 -**Alarm Address: **It is used for setting word address for word alarm, such as HDW0. 86 +**(2) Alarm Address: **It is used for setting word address for word alarm, such as HDW0. 84 84 85 -**Data Format: **16-bit unsigned decimal, 16-bit signed decimal, 16-bit BCD, 32-bit unsigned decimal, 32-bit signed decimal, 32-bit BCD, 32-bit float. 88 +**(3) Data Format: **16-bit unsigned decimal, 16-bit signed decimal, 16-bit BCD, 32-bit unsigned decimal, 32-bit signed decimal, 32-bit BCD, 32-bit float. 86 86 87 -**Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 90 +**(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 88 88 89 -**Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 92 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 90 90 91 91 **✎Note:** 92 92 ... ... @@ -100,11 +100,11 @@ 100 100 |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 101 101 |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 102 102 103 -**Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. 106 +**(6) Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. 104 104 105 -**Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 108 +**(7) Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 106 106 107 -**Alarm Condition**: Alarm is triggered when designated address meets the alarm condition, it provides four conditions; 110 +**(8) Alarm Condition**: Alarm is triggered when designated address meets the alarm condition, it provides four conditions; 108 108 109 109 1. **High alarm:** Alarm is triggered when it reaches high limit. It can be a constant or a variable 110 110 1. **Low alarm:** Alarm is triggered when it reaches low limit. It can be a constant or a variable ... ... @@ -111,11 +111,11 @@ 111 111 1. **Range alarm:** Alarm is triggered when it exceeds the range. It can be a constant or a variable 112 112 1. **Equivalent alarm: **Alarm is triggered when the value equals to the given data. It can be a constant or a variable 113 113 114 -**Alarm Info: **It is used for setting alarm content (command); 117 +**(9) Alarm Info: **It is used for setting alarm content (command); 115 115 116 -**Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. 119 +**(10) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. 117 117 118 -**Alarm Screen: **Pop-up alarm screen (it need to be sub-screen); 121 +**(11) Alarm Screen: **Pop-up alarm screen (it need to be sub-screen); 119 119 120 120 1. **Position: **The location of the screen alarm display. 121 121 1. **Pop-up Interval: **The time of reopen the alarm screen when alarm screen closed. ... ... @@ -122,36 +122,38 @@ 122 122 1. **Pop-up once: **Pop up alarm screen once. 123 123 1. **Close window when alarm off: **Automatically close the alarm screen when alarm off. 124 124 125 -**Beep when alarm ON: **beep works when the alarm is triggered, in the default mode, the beep works until the alarm is released. 128 +**(12) Beep when alarm ON: **beep works when the alarm is triggered, in the default mode, the beep works until the alarm is released. 126 126 127 -**Beep once:** Beep works once, when alarm is triggered. 130 +**(13) Beep once:** Beep works once, when alarm is triggered. 128 128 129 -**Alarm List** 132 +**(14) Alarm List** 130 130 131 131 It displays all the word alarm lists; it will show the alarm information; 132 132 133 133 **Operating Procedures of Adding One Alarm** 134 134 135 - *Click "Project"→"Word Alarm" as below shows.138 +1. Click "Project"-> "Word Alarm" as below shows. 136 136 137 137 (% style="text-align:center" %) 138 138 [[image:8.Basic Function_html_1b59522c984cd7c2.png||height="144" width="492" class="img-thumbnail"]] 139 139 140 -* Click "AddClick" button to open "Word Alarm" setting window. 143 +(% start="2" %) 144 +1. Click [Add] button to open [Word Alarm] setting window. 141 141 142 142 (% style="text-align:center" %) 143 143 [[image:8.Basic Function_html_942107c81fc6901c.png||height="307" width="554" class="img-thumbnail"]] 144 144 145 -* Set Basic information of word alarm. 146 -* Set "Content". 147 -* Other settings can be set according to the actual situation. 148 -* Click "OK" button to complete settings. 149 +(% start="3" %) 150 +1. Set Basic information of word alarm. 151 +1. Set "Content". 152 +1. Other settings can be set according to the actual situation. 153 +1. Click "OK" button to complete settings. 149 149 150 150 **HMI Alarm Demo Download Link** 151 151 152 152 [[https:~~/~~/drive.google.com/open?id=1Llq03CMISM_1mMIfU308hxFbs4rGdQGP>>url:https://drive.google.com/open?id=1Llq03CMISM_1mMIfU308hxFbs4rGdQGP]] 153 153 154 -= **Recipe** = 159 += **{{id name="_Toc17174"/}}{{id name="_Recipe"/}}Recipe** = 155 155 156 156 Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC. 157 157 ... ... @@ -176,85 +176,104 @@ 176 176 (% style="text-align:center" %) 177 177 [[image:8-1Recipe.png]] 178 178 179 -**Basic** 184 +**(1) Basic** 180 180 181 -* **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object); 182 -** **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters; 183 -* **Group: **Set the recipe group number, the number of elements, the data format. The data format has 8 modes: 16-bit signed decimal, 16-bit unsigned decimal, 16-bit BCD, 32-bit signed decimal, 32-bit unsigned decimal, 16-bit BCD, 32-bit floating point number, 64-bit (double-precision) floating-point number, string, and the choice of data integer and decimal places. 184 -* **Elements:** It sets members' initial number of each group; 185 -* **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form; 186 -* **Decimal: **It sets integer and scale digits; 186 +1. **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object); 187 187 188 -** Mode Selection: **Select Simple or Advanced mode.Recipefile isdividedinto simplemodeandadvanced mode. Onlyin advanced mode canexistmultiple recipefilesusedatthe same time.(usedwiht file list onject),Simplemodecan only supporta recipefile; Aadvanced mode caninsertgroupinformationandreordered.188 +* **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters; 189 189 190 -Function address: all operations are done through function addresses, different operating value is as follows: 190 +(% start="2" %) 191 +1. **Group: **It sets the groups' initial number of recipe; 192 +1. **Elements:** It sets members' initial number of each group; 193 +1. **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form; 194 +1. **Decimal: **It sets integer and scale digits; 191 191 192 -* = 0: no operation; 193 -* = 1: trigger read data; 194 -* = 2: new trigger or update (If there is group number, it updates.) 195 -* = 4: insert (only valid in advanced mode) 196 -* = 8: delete (Delete according to the writing group number. If write and read address are consistent, refer to the reading group number); 197 -* = 16: delete and sorted ((Delete according to the writing group number. If write and read address are consistent, refer to the reading group number) 198 -* = 64: import CSV recipe file. 196 +**(2) Mode Selection** 199 199 200 - **UseMultipleFile**198 +Users could select Simple or Advanced mode. 201 201 200 +**(3) Function Address:** 201 + 202 +All the operations for recipe is by this address 203 + 204 +* =0 No operation. 205 +* =1 Read data from recipe. 206 +* =2 Insert a new group or write data to exist group. 207 +* =4 Inserted (only advanced mode). 208 +* =8 Delete. 209 +* =16 Delete and Sequence. 210 + 211 +**(4) Use Multiple File** 212 + 202 202 Check it to use more than one recipe file in HMI, but this option only valid in [Advanced mode]; 203 203 204 -**Select language** 215 +**(5) Select language** 205 205 206 206 The text in HMI can be in 8 languages, user can set language in here; 207 207 208 -**Address** 219 +**(6) Address** 209 209 210 210 1. **Group:** This address is for selecting group number; 211 211 1. **Start: **This is starting address is for reading and writing in recipe, PIStudio will automatically assigns addresses for each members; 212 212 1. **File(16 words): **This address only available when enable the Use Multiple File. This setting address is for input the recipe file's filename. 213 213 214 -**Use Index** 225 +**(7) Use Index** 215 215 216 216 If the value from Group address is changed, Read address will display the new data according to new group number immediately. Relatively, if the data of write address is changed, the corresponding group from table is also changed. 217 217 218 -**Query by Element** 229 +**(8) Query by Element** 219 219 220 220 Enable it for querying group by specify element, select a primary key from all the elements, except the group number. This element value from all groups must be unique if want to set as primary key; 221 221 222 -(% class="box infomessage" %) 223 -((( 224 224 **✎Note: **When this option is enabled, Group address will be invalid. 225 -))) 226 226 227 -**Use Independent Write Address** 235 +**(9) Use Independent Write Address** 228 228 229 229 To separate Recipe read address and write address. 230 230 231 -**Use Insert** 239 +**(10) Use Insert** 232 232 233 233 It inserts data into the specified group, if the specified group already exists, it would not cover the original data, while it will move the original group next one after it. 234 234 235 -**Discontinuous Address** 243 +**(11) Discontinuous Address** 236 236 237 237 Whether enable the non-consecutive recipe operation addresses or not. If disabled, the recipe address will recover as the continuous addresses. 238 238 239 -(% class="box infomessage" %) 240 -((( 241 241 **✎Note: **This function only supported in HMI+, i series, ie series, ig series. 242 -))) 243 243 244 -** RecipeDemo Download Link:**[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]249 +**Operating Procedures** 245 245 246 - =(% style="color:inherit; font-family:inherit;font-size:29px"%)**Traditionalrecipe**(%%)=251 +1) Click "Project"->"Bit Alarm" as below shows. 247 247 253 +(% style="text-align:center" %) 254 +[[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]] 255 + 256 +2) Click "Add" button to open "Recipe" setting window. 257 + 258 +(% style="text-align:center" %) 259 +[[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]] 260 + 261 +3) Set basic settings for recipe. 262 + 263 +4) Select mode according to actual condition. 264 + 265 +5) Other settings can be set according to the actual situation. 266 + 267 +6) Click [OK] button to complete settings. 268 + 269 +**Recipe Demo Download Link** 270 + 271 +[[https:~~/~~/drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]] 272 + 273 += (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional Recipe**(%%) = 274 + 248 248 Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC. 249 249 250 250 Traditional recipe function is valid only when the LEVI project is converted to the PI project, and the original project uses the traditional recipe. 251 251 252 -(% class="box infomessage" %) 253 -((( 254 254 **✎Note**: Currently, only HMI+, i series, ie series, and ig series support the traditional recipe. 255 -))) 256 256 257 -== Simple recipe mode == 281 +== **Simple recipe mode** == 258 258 259 259 Click the "Traditional Recipe" [[image:8-2TraditionalRecipe.png]] in the "Data tool" bar in the upper side of the software, and the following interface will pop up: 260 260 ... ... @@ -266,19 +266,16 @@ 266 266 * The recipe folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (''). 267 267 * The element name of the recipe cannot include following 5 special characters: " **,** " , " **|** " , " **<** " , " **>** " , " **&** " . 268 268 269 -== Recipe display == 293 +== **Recipe display** == 270 270 271 271 Select the file type "Traditional recipe file" in object "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line. 272 272 273 -(% class="box infomessage" %) 274 -((( 275 275 **✎Note**: The Recipe Display can display up to 50 groups of 100 elements by default, which can be to display out of range by enabled "Address Control". After the "Address Control" is enabled, the display group number can be reached to 100. If want to display more than 100, please adjust the "Start Group" from "Address Control" to index the display group, as following shown: 276 -))) 277 277 278 278 (% style="text-align:center" %) 279 279 [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]] 280 280 281 -== Recipe transmission address == 302 +== **Recipe transmission address** == 282 282 283 283 The special addresses used in the Recipe are shown in the following table: 284 284 ... ... @@ -329,26 +329,26 @@ 329 329 1. The RPW register only supports word address access. 330 330 1. It can be known from the coding method of RPW~*~*~#~#~#~# that the range of RPW is from RPW000000-RPW990450, wherein the range of group number is 0-100, and the range of element is 0-450. 331 331 332 -== Recipe example == 353 +== **Recipe example** == 333 333 334 334 The recipe index makes the modification and display of recipe data more convenient. Only need to modify and display the data of the recipe file through "Numeric Input/Display" Object and "Word Switch". 335 335 336 -Edit the recipe configuration, create three groups of recipes, 4 elements for per group: Red, green, blue, spraying time, as following shown: 357 +(1) Edit the recipe configuration, create three groups of recipes, 4 elements for per group: Red, green, blue, spraying time, as following shown: 337 337 338 338 (% style="text-align:center" %) 339 339 [[image:8-5TraditionalRecipeCaseConfig.png]] 340 340 341 -RPW 0~~3 can display the data of group for the selected line. RPW10000~~10003, RPW20000~~20003, RPW30000~~30003 each address can display the single element. Directly modify the content of the RPW address and then modify the recipe data, as following shown: 362 +(2) RPW 0~~3 can display the data of group for the selected line. RPW10000~~10003, RPW20000~~20003, RPW30000~~30003 each address can display the single element. Directly modify the content of the RPW address and then modify the recipe data, as following shown: 342 342 343 343 (% style="text-align:center" %) 344 344 [[image:8-7TraditionalRecipeCaseShowNoOpera.png]] 345 345 346 -After selecting the 2nd group, trigger the download button to download the whole group data to the corresponding element address (For this case, the data will write into HDW0~~3), or trigger the upload button to upload the content of the element address to the specified recipe group. 367 +(3) After selecting the 2nd group, trigger the download button to download the whole group data to the corresponding element address (For this case, the data will write into HDW0~~3), or trigger the upload button to upload the content of the element address to the specified recipe group. 347 347 348 348 (% style="text-align:center" %) 349 349 [[image:8-6TraditionalRecipeCaseShow.png]] 350 350 351 -= **Trend chart** =372 += **{{id name="_Toc5565"/}}{{id name="_Trend_Chart"/}}Trend Chart** = 352 352 353 353 Trend chart function is used for displaying the real-time data in HMI as curve graph, which X axis represent as time, Y axis represent as data. 354 354 ... ... @@ -386,20 +386,17 @@ 386 386 387 387 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 388 388 389 -(% class="box infomessage" %) 390 -((( 391 391 **✎Note: **Curve names can only consist of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_') (' '), and other non-English characters. 392 -))) 393 393 394 394 **Trend Chart Demo Download Link** 395 395 396 396 [[https:~~/~~/drive.google.com/open?id=1smnaAvSxOWC0WQK4_uvqHXWn4vUZxGJC>>url:https://drive.google.com/open?id=1smnaAvSxOWC0WQK4_uvqHXWn4vUZxGJC]] 397 397 398 -= **History XY plot** =416 += **{{id name="_Toc7121"/}}{{id name="_History_XY_Plot"/}}History XY Plot** = 399 399 400 400 Different from TrendChart, uses need to set history XY curve items in project. Please click "Project"-> "History XY Plot" to open the setting screen. 401 401 402 -Recipe function settings will be display in "[[History XY Plot>>path:http s://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HHistoryXYplot]]" object.420 +Recipe function settings will be display in "[[History XY Plot>>path:http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HHistoryXYplot]]" object. 403 403 404 404 (% style="text-align:center" %) 405 405 [[image:历史XY 2.png||class="img-thumbnail"]] ... ... @@ -431,31 +431,29 @@ 431 431 432 432 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 433 433 434 -(% class="box infomessage" %) 435 -((( 436 436 **✎Note: **Curve names can only consist of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_') (' '), and other non-English characters. 437 -))) 438 438 439 439 **Operating Procedure** 440 440 441 - *Click "Project"→"History XY Plot" to open the function selecting windows.456 +1. Click "Project" -> "History XY Plot" to open the function selecting windows. 442 442 443 443 (% style="text-align:center" %) 444 444 [[image:8.Basic Function_html_5da6ca44bd28acbe.png||height="144" width="533" class="img-thumbnail"]] 445 445 446 -* Click "Add" button to open "History XY Plot” setting windows. 461 +(% start="2" %) 462 +1. Click "Add" button to open [History XY Plot] setting windows. 447 447 448 448 (% style="text-align:center" %) 449 449 [[image:8.Basic Function_html_6345b50ea55168fa.png||height="307" width="554" class="img-thumbnail"]] 450 450 451 - *Setting the function of History XY Plot.452 - *Click "OK" to save the setting.467 +1. Setting the function of History XY Plot. 468 +1. Click "OK" to save the setting. 453 453 454 454 **Download Link** 455 455 456 456 [[https:~~/~~/drive.google.com/open?id=1t4_HuRmIJJ-B5ryA2kVMadD9FywKhZ4r>>url:https://drive.google.com/open?id=1t4_HuRmIJJ-B5ryA2kVMadD9FywKhZ4r]] 457 457 458 -= (% style="color:inherit; font-family:inherit; font-size:29px" %)**Data record**(%%) =474 += (% style="color:inherit; font-family:inherit; font-size:29px" %)**Data Record**(%%) = 459 459 460 460 The data record function is organized according to the structure below. In a project, there can be multiple record groups, each record group containing multiple channels. Different groups have different sampling times. 461 461 ... ... @@ -476,9 +476,9 @@ 476 476 477 477 ✎**Note: ** 478 478 479 -After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Data record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 495 +1) After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Data record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 480 480 481 -The number of Data records upload to Cloud shall not exceed the limit value, or the sum of the imported Data records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 497 +2) The number of Data records upload to Cloud shall not exceed the limit value, or the sum of the imported Data records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 482 482 483 483 (% style="margin-left:auto; margin-right:auto; width:513px" %) 484 484 |=(% style="width: 70px;" %)Series|=(% style="width: 442px;" %)Number of Data Record upload to Cloud ... ... @@ -487,10 +487,11 @@ 487 487 |(% style="width:70px" %)3000ig|(% style="text-align:center; width:442px" %)50 488 488 |(% style="width:70px" %)8000ig|(% style="text-align:center; width:442px" %)100 489 489 490 -The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters. 506 +3) The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters. 491 491 492 -Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ". 508 +4) Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ". 493 493 510 + 494 494 (% class="wikigeneratedid" id="HSettings" %) 495 495 **Settings** 496 496 ... ... @@ -560,10 +560,17 @@ 560 560 * The channel name does not include these 5 special characters: ", ", "| "," <", "> "," & ". 561 561 * The data would be overwritten automatically if the capacity exceed the maximum capacity. For 8000/9000 series, the size of single file cannot exceed 300MB, and total capacity of data records cannot exceed 1000MB. For 3000/3000i/3000ie series, the size of single file cannot exceed 4MB, and total capacity of data records cannot exceed 10MB. If the total amount exceeds the range , an error will be prompted when the project is compiled. 562 562 563 -You could click here to jump to object "[[Data Record Display>>http s://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDatarecorddisplay]]"580 +You could click here to jump to object "[[Data Record Display>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HDataRecordDisplay]]" 564 564 565 -= **User permission** = 582 +(% class="wikigeneratedid" id="H" %) 583 +**PI Data Record Demo Download** 566 566 585 +**[[Demo Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 586 + 587 +**[[Video Link>>https://drive.google.com/open?id=1h7VUsIJqH4LIRjjtphbv9Kmzd6jUMPtE]]** 588 + 589 += **{{id name="_Toc3497"/}}{{id name="_User_Permission"/}}User Permission** = 590 + 567 567 **Introduction** 568 568 569 569 1. User permission is one of expansion function in PI Series HMI; it provides multi-level of permission for control HMI operations. ... ... @@ -571,14 +571,11 @@ 571 571 1. Operating record: it records user operations information, the records files are saved in HMI flash; its path is [~\~\flash~\~\UserOperationLogs.db]. 572 572 1. When it is on simulator mode, the files are saved in C disk, its path is [C:~\~\WECON\UserMgrFile\UserOperationLogs.db]. 573 573 574 -(% class="box infomessage" %) 575 -((( 576 576 ✎**Note: **The user name and password must be unique. 577 -))) 578 578 579 -== Settings == 600 +== **Settings** == 580 580 581 -Open PIStudio software, then operate as the following figure. 602 +**Open PIStudio software, then operate as the following figure.** 582 582 583 583 (% style="text-align:center" %) 584 584 [[image:用户权限 1.png||class="img-thumbnail"]] ... ... @@ -597,26 +597,25 @@ 597 597 * When the configured file does not have the administrator account, a new user can be added through "Funtion address" and set as the administrator. 598 598 * If you select hidden fucntion when configuring user account, the account would display as "~*~*~*~*~*~*" in the list. You only need to enter the password of the corresponding hidden user to log in. 599 599 600 -== Object permission configuration == 621 +== **Object permission configuration** == 601 601 602 602 (% style="text-align:center" %) 603 603 [[image:用户权限 2.png||class="img-thumbnail"]] 604 604 605 -**Operation Procedure of Object Permission** 626 +{{id name="OLE_LINK3"/}}{{id name="OLE_LINK4"/}}**Operation Procedure of Object Permission** 606 606 607 607 1. Open the object setting windows; 608 -1. Select "Security"windows;609 -1. Check the "User Permission";610 -1. Select "Level"to set permission level;611 -1. Enter "Log Message", it is for operation records, if it was empty, the operation for this object would be not be recorded;612 -1. Select the "Access Denied Setting"mode;629 +1. Select [Security] windows; 630 +1. Check the [User Permission]; 631 +1. Select [Level] to set permission level; 632 +1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded; 633 +1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode; 613 613 614 614 **Log information description** 615 615 616 -A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 637 +1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 638 +1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. 617 617 618 -The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. 619 - 620 620 The data format are as follows. 621 621 622 622 (% class="table-bordered" %) ... ... @@ -632,7 +632,8 @@ 632 632 |W|Single word 633 633 |D|Double word 634 634 635 -Examples. 655 +(% start="3" %) 656 +1. Examples. 636 636 637 637 * Unsigned decimal, BCD, 32-bit float and Signed decimal are as follows. 638 638 ... ... @@ -755,7 +755,7 @@ 755 755 756 756 [[https:~~/~~/drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq>>url:https://drive.google.com/open?id=1qOiEDvo_1H1YqpoLDpS77dGaAFm8nrGq]] 757 757 758 -= Message 779 += **{{id name="_Toc29015"/}}{{id name="_MessagePrompt"/}}Message Prompt** = 759 759 760 760 A message box is a window used to show some prompts or warnings to users. For example, the application process a task in the process of pop-up message box, suggesting that "U disk has been detected", then the customer can carry out data dump function. 761 761 ... ... @@ -822,10 +822,12 @@ 822 822 823 823 For example: 824 824 825 -* In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100. 826 -* For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 827 -* For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 846 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100. 828 828 848 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 849 + 850 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 851 + 829 829 **(2) Server Selection** 830 830 831 831 **Server**: China, ASEAN, and Europe.
- image-20220805170000-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.1 KB - Content
- image-20220805170046-2.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.5 KB - Content
- image-20220805170102-3.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.3 KB - Content
- image-20220805170147-4.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.3 KB - Content
- image-20220805170232-5.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.3 KB - Content