Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -241,13 +241,29 @@ 241 241 **✎Note: **This function only supported in HMI+, i series, ie series, ig series. 242 242 ))) 243 243 244 -[[image:image-20220805174501-1.jpeg]] 245 245 246 - [[image:image-20220805174543-2.jpeg]]245 +**description of Adcanced mode** 247 247 248 - **RecipeDemoDownloadLink:**[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]247 +According to the recipe configuration information in Figure 2 above. The function address is HDW70, and each function configuration corresponds to the group number address, recipe element address and recipe file name address. The recipe information configured in figure 2 can be displayed in the table in figure 3 with the "Record Display" object. 249 249 249 +[[image:image-20220806111333-1.jpeg]] 250 250 251 +**Read recipe**: Input 1 to the file name, when the group number addresses HDW100=1 and HDW70=1 (read), the element data of the first group (ID=1) is written to the recipe address from the recipe file. As shown in Figure 3 above: HDW105=1, HHDW106=2, HDW107=3, HDW108=4, HDW109=5. 252 + 253 +**Write recipe**: Input 1 to the file name, when the group number addresses HDW101=4 and HDW70=2 (write), the data will be read from the recipe address and written to the corresponding group of the recipe file. As shown in figure 3 above: HDW110=20, HHDW111=21, HDW112=22, HDW113=23, HDW114=24. Write the data of this set to the elements of ID=4 in the recipe table (if there is no data of Group 4 in the recipe file, a new set of data will be added; If there is data of Group 4 in the original recipe, the original data will be overwritten and the latest data will be displayed in the recipe file). 254 + 255 +**Index recipe**: When the file name is input 1, when the group number address HDW102=3, the data of ID=3 (Group 3) in the recipe file will be directly displayed in the component address of the index, that is, HDW115=11, HHDW116=12, HDW117=13, HDW118=14 and HDW119=15. If the data of the index component address is modified, the modified data will be automatically filled into the table of the recipe file, that is, the data of the recipe file will be automatically updated after the data is modified. 256 + 257 +[[image:image-20220806111355-2.jpeg]] 258 + 259 +**Insert recipe**: Input 1 to the file name, when the group number addresses HDW103=3 and HDW70=4 (insert), the data of the 3rd group will be inserted, but the data of the third group already exists in the original recipe file (see Figure 3 above), then the original data will be moved down by one group, that is, the original 3rd group will become the 4th group, and so on, and HDW120=16, HHDW121=17, HDW122=18, HDW123=19 and HDW124=20 will be written into the new 3rd group of the recipe file at the same time. The results are shown in Figure 4 above. 260 + 261 +When the group number address HDW101=2 (**The delete function only works on the group number of the write function**), HDW70=8 (delete), the data in the recipe file with ID=2 (Group 2) will be deleted. 262 + 263 +When the group number address HDW101=5 (**The delete function only works on the group number of the write function**), HDW70=16 (delete and sort), the data of ID=5 (Group 5) in the recipe file will be deleted, and the original ID=6 (Group 6) data will be reordered to become the new Group 5 data, the original ID=7 (Group 7) data will be reordered to become the new Group 6 data, and so on. 264 + 265 +**Recipe Demo Download Link: **[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]] 266 + 251 251 == Calling CSV recipe file == 252 252 253 253 **Overview** ... ... @@ -284,7 +284,7 @@ 284 284 * = 0: In the CsvFile directory of U disk 285 285 * = 1: In the CsvFile directory of the SD card 286 286 287 -The path for offline simulation is: C:\ HMIEmulation\ CustomFileDir\ CsvFile 303 +**The path for offline simulation is: C:\ HMIEmulation\ CustomFileDir\ CsvFile** 288 288 ))) 289 289 |HSW242|Numerical input object|Returns the results of the csv import:((( 290 290 * = 37: CSV file imported successfully ... ... @@ -306,71 +306,43 @@ 306 306 307 307 * HSW1066=1: Import the normal recipe file of regular series HMI (the data in line 1 of the file is invalid); 308 308 309 -The data in line 1 of the normal recipe file is used to define the format of the recipe and will not be imported into the recipe table as recipe information, but you must ensure that the data in line 1 representing the elements and number of groups is correct, otherwise the CSV recipe file will fail to be imported. 325 +The data in line 1 of the normal recipe file is used to define the format of the recipe and will not be imported into the recipe table as recipe information, **but you must ensure that the data in line 1 representing the elements and number of groups is correct, otherwise the CSV recipe file will fail to be imported.** 310 310 327 +(% style="text-align:center" %) 328 +[[image:image-20220806101520-6.jpeg]] 311 311 330 +* HSW1066=2: Import the special recipe file of regular series HMI (the data in line 1, 2 and column 1 of the file are invalid); 312 312 313 - C) HSW1066=2:Importthe special recipe file of regularseriesHMI(thedatainline 1, 2 and column 1 of thefileare invalid);332 +In the special recipe file, line 1 is used to define the format of the recipe, line 2 is used to define the element name of the recipe, and column 1 is used to define the group name of the recipe, so lines 1, 2 and column 1 of the special recipe will not be imported into the recipe table as recipe information. **During use, ensure that the data such as the number of groups and elements representing the recipe format in the first line are correct, otherwise the import of the CSV recipe file will fail.** 314 314 334 +(% style="text-align:center" %) 335 +[[image:image-20220806102610-7.jpeg]] 315 315 316 - In thespecialrecipefile, line 1 is used todefine the formatof the recipe, line 2 is used to define the element name of the recipe, and column 1 is used to define the group name ofthe recipe, so lines 1, 2 and column 1 of the special recipe will not be imported into the recipe table as recipe information. During use, ensure that the data such as the number of groups and elements representing the recipe format in the first line are correct, otherwise the import of the CSV recipe file will fail.337 +**Perform import** 317 317 339 +After configuring the saving path of CSV recipe file, the name of recipe file and the type of recipe according to the above steps, the method of transferring CSV file to DB file is as follows: 318 318 341 +* Configure the DB recipe file name by text input object: HDW500 = 3 (recipe file configured in Figure 1), 342 +* Set the recipe function address to: HDW1000 = 64 (the function address configured in Figure 1), 343 +* Transform the CSV recipe file in U disk into DB recipe file with file name “3.rcp2”. 319 319 345 +**DB recipe file for storing CSV data:** 320 320 321 - (3)Performimport347 +Simple mode: When the recipe file is set to simple mode, the file of CSV data is saved as the DB recipe file of 1. rcp2 by default. 322 322 349 +Advanced mode: When the recipe is enabled in advanced mode (multi-file recipe), the imported CSV file data is saved to the file recorded at the recipe file address HDW500 (the address configured in Figure 1). 323 323 324 - After configuring the saving path of CSV recipe file, the name of recipe file and the typeofrecipe accordingtothe above steps, the method of transferring CSV fileto DB file isas follows:351 +**Import results:** 325 325 353 +* HSW242 = 37: Import succeeded; 354 +* HSW242 = 38: Import failed. 326 326 327 - A) Configurethe DB recipe file name by text inputobject: HDW500 = 3 (recipe file configured in Figure 1),356 +**Precautions:** 328 328 358 +* Ensure that the data format of each element in the CSV file is the same as the recipe data format set in the software (DB), and ensure that the elements of each row in the valid data area is the same as the elements set in the software (DB); 359 +* When the elements of a line in CSV file is more than the elements set in the software (DB), it will prompt the import failure; 360 +* When the CSV file imported into the regular series HMI is a recipe file, the data representing the recipe format (elements, number of groups, whether it is a special recipe) in line 1 must be correct, otherwise the import of CSV file will fail. 329 329 330 - B) Set the recipe function address to: HDW1000 = 64 (the function address configured in Figure 1), 331 - 332 - 333 - C) Transform the CSV recipe file in U disk into DB recipe file with file name “3.rcp2”. 334 - 335 - 336 -5. DB recipe file for storing CSV data: 337 - 338 - 339 -(1) Simple mode: 340 - 341 - 342 - When the recipe file is set to simple mode, the file of CSV data is saved as the DB recipe file of 1. rcp2 by default. 343 - 344 - 345 -(2) Advanced mode: 346 - 347 - 348 - When the recipe is enabled in advanced mode (multi-file recipe), the imported CSV file data is saved to the file recorded at the recipe file address HDW500 (the address configured in Figure 1). 349 - 350 - 351 -6. Import results: 352 - 353 - 354 -(1) HSW242 = 37: Import succeeded; 355 - 356 - 357 -(2) HSW242 = 38: Import failed. 358 - 359 - 360 - 361 -3. Precautions: 362 - 363 - 364 -~1. Ensure that the data format of each element in the CSV file is the same as the recipe data format set in the software (DB), and ensure that the elements of each row in the valid data area is the same as the elements set in the software (DB); 365 - 366 - 367 -2. When the elements of a line in CSV file is more than the elements set in the software (DB), it will prompt the import failure; 368 - 369 - 370 -3. When the CSV file imported into the regular series HMI is a recipe file, the data representing the recipe format (elements, number of groups, whether it is a special recipe) in line 1 must be correct, otherwise the import of CSV file will fail. 371 - 372 - 373 - 374 374 = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) = 375 375 376 376 Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.
- image-20220806101520-6.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.8 KB - Content
- image-20220806102610-7.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.9 KB - Content
- image-20220806111333-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.4 KB - Content
- image-20220806111355-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.4 KB - Content