Changes for page 06 Data Tool

Last modified by Jett on 2025/02/18 16:43

From version 24.7
edited by Stone Wu
on 2022/08/06 10:26
Change comment: There is no comment for this version
To version 24.6
edited by Stone Wu
on 2022/08/06 10:25
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -315,9 +315,6 @@
315 315  
316 316  In the special recipe file, line 1 is used to define the format of the recipe, line 2 is used to define the element name of the recipe, and column 1 is used to define the group name of the recipe, so lines 1, 2 and column 1 of the special recipe will not be imported into the recipe table as recipe information. **During use, ensure that the data such as the number of groups and elements representing the recipe format in the first line are correct, otherwise the import of the CSV recipe file will fail.**
317 317  
318 -(% style="text-align:center" %)
319 -[[image:image-20220806102610-7.jpeg]]
320 -
321 321  **Perform import**
322 322  
323 323  After configuring the saving path of CSV recipe file, the name of recipe file and the type of recipe according to the above steps, the method of transferring CSV file to DB file is as follows:
... ... @@ -339,10 +339,15 @@
339 339  
340 340  **Precautions:**
341 341  
342 -* Ensure that the data format of each element in the CSV file is the same as the recipe data format set in the software (DB), and ensure that the elements of each row in the valid data area is the same as the elements set in the software (DB);
343 -* When the elements of a line in CSV file is more than the elements set in the software (DB), it will prompt the import failure;
344 -* When the CSV file imported into the regular series HMI is a recipe file, the data representing the recipe format (elements, number of groups, whether it is a special recipe) in line 1 must be correct, otherwise the import of CSV file will fail.
339 +Ensure that the data format of each element in the CSV file is the same as the recipe data format set in the software (DB), and ensure that the elements of each row in the valid data area is the same as the elements set in the software (DB);
345 345  
341 +When the elements of a line in CSV file is more than the elements set in the software (DB), it will prompt the import failure;
342 +
343 +
344 +3. When the CSV file imported into the regular series HMI is a recipe file, the data representing the recipe format (elements, number of groups, whether it is a special recipe) in line 1 must be correct, otherwise the import of CSV file will fail.
345 +
346 +
347 +
346 346  = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) =
347 347  
348 348  Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.