Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Karen - Content
-
... ... @@ -24,7 +24,7 @@ 24 24 * After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 25 25 * The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 26 26 27 -(% style="margin-left:auto; margin-right:auto; width:358px" %) 27 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:358px" %) 28 28 |=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 29 29 |(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 30 30 |(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 ... ... @@ -241,13 +241,29 @@ 241 241 **✎Note: **This function only supported in HMI+, i series, ie series, ig series. 242 242 ))) 243 243 244 -[[image:image-20220805174501-1.jpeg]] 245 245 246 - [[image:image-20220805174543-2.jpeg]]245 +**description of Adcanced mode** 247 247 248 - **RecipeDemoDownloadLink:**[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]]247 +According to the recipe configuration information in Figure 2 above. The function address is HDW70, and each function configuration corresponds to the group number address, recipe element address and recipe file name address. The recipe information configured in figure 2 can be displayed in the table in figure 3 with the "Record Display" object. 249 249 249 +[[image:image-20220806111333-1.jpeg]] 250 250 251 +**Read recipe**: Input 1 to the file name, when the group number addresses HDW100=1 and HDW70=1 (read), the element data of the first group (ID=1) is written to the recipe address from the recipe file. As shown in Figure 3 above: HDW105=1, HHDW106=2, HDW107=3, HDW108=4, HDW109=5. 252 + 253 +**Write recipe**: Input 1 to the file name, when the group number addresses HDW101=4 and HDW70=2 (write), the data will be read from the recipe address and written to the corresponding group of the recipe file. As shown in figure 3 above: HDW110=20, HHDW111=21, HDW112=22, HDW113=23, HDW114=24. Write the data of this set to the elements of ID=4 in the recipe table (if there is no data of Group 4 in the recipe file, a new set of data will be added; If there is data of Group 4 in the original recipe, the original data will be overwritten and the latest data will be displayed in the recipe file). 254 + 255 +**Index recipe**: When the file name is input 1, when the group number address HDW102=3, the data of ID=3 (Group 3) in the recipe file will be directly displayed in the component address of the index, that is, HDW115=11, HHDW116=12, HDW117=13, HDW118=14 and HDW119=15. If the data of the index component address is modified, the modified data will be automatically filled into the table of the recipe file, that is, the data of the recipe file will be automatically updated after the data is modified. 256 + 257 +[[image:image-20220806111355-2.jpeg]] 258 + 259 +**Insert recipe**: Input 1 to the file name, when the group number addresses HDW103=3 and HDW70=4 (insert), the data of the 3rd group will be inserted, but the data of the third group already exists in the original recipe file (see Figure 3 above), then the original data will be moved down by one group, that is, the original 3rd group will become the 4th group, and so on, and HDW120=16, HHDW121=17, HDW122=18, HDW123=19 and HDW124=20 will be written into the new 3rd group of the recipe file at the same time. The results are shown in Figure 4 above. 260 + 261 +When the group number address HDW101=2 (**The delete function only works on the group number of the write function**), HDW70=8 (delete), the data in the recipe file with ID=2 (Group 2) will be deleted. 262 + 263 +When the group number address HDW101=5 (**The delete function only works on the group number of the write function**), HDW70=16 (delete and sort), the data of ID=5 (Group 5) in the recipe file will be deleted, and the original ID=6 (Group 6) data will be reordered to become the new Group 5 data, the original ID=7 (Group 7) data will be reordered to become the new Group 6 data, and so on. 264 + 265 +**Recipe Demo Download Link: **[[Download>>url:https://drive.google.com/open?id=1Cjbq_tW-NIirHFBpxt47g7IKvoYaWqUR]] 266 + 251 251 == Calling CSV recipe file == 252 252 253 253 **Overview** ... ... @@ -673,7 +673,10 @@ 673 673 674 674 (% class="box infomessage" %) 675 675 ((( 676 -✎**Note: **The user name and password must be unique. 692 +✎**Note: ** 693 + 694 +* The user name and password must be unique. 695 +* The multi language function of User permission only supported on HMI system version V2.0 or above 677 677 ))) 678 678 679 679 == Settings == ... ... @@ -683,6 +683,11 @@ 683 683 (% style="text-align:center" %) 684 684 [[image:用户权限 1.png||class="img-thumbnail"]] 685 685 705 +Click on the cell from UserName and Desc, which can support the multi language. 706 + 707 +(% style="text-align:center" %) 708 +[[image:UserPermissionMultilan.png]] 709 + 686 686 1. Click "User Permission" in "Data Tool" toolbar. 687 687 1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users. 688 688 1. Edit password, click "User0" cell under "PassWord", and then enter the user name. ... ... @@ -696,6 +696,9 @@ 696 696 * Only a maximum of one administrator permission is allowed in a profile with one user permission. If you want to use "Funtion address" to modify the user permission, you must log in the administrator account to operate. 697 697 * When the configured file does not have the administrator account, a new user can be added through "Funtion address" and set as the administrator. 698 698 * If you select hidden fucntion when configuring user account, the account would display as "~*~*~*~*~*~*" in the list. You only need to enter the password of the corresponding hidden user to log in. 723 +* ((( 724 +Adding new UserName and Desc on the HMI by special addresses in the current language of the HMI, other languages will also configure the user names and user descriptions to the current language by default, i.e. switching to other languages, the new user names and user descriptions will not change with the language. 725 +))) 699 699 700 700 == Object permission configuration == 701 701 ... ... @@ -702,6 +702,11 @@ 702 702 (% style="text-align:center" %) 703 703 [[image:用户权限 2.png||class="img-thumbnail"]] 704 704 732 +User operation logs support multi languages configuration. Click on the Log Message, the text editor of multi language will be pop up: 733 + 734 +(% style="text-align:center" %) 735 +[[image:LogMessagesMultilan.png]] 736 + 705 705 **Operation Procedure of Object Permission** 706 706 707 707 1. Open the object setting windows;
- LogMessagesMultilan.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.5 KB - Content
- UserPermissionMultilan.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.2 KB - Content
- image-20220806111333-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.4 KB - Content
- image-20220806111355-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.4 KB - Content