Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -284,7 +284,7 @@ 284 284 * = 0: In the CsvFile directory of U disk 285 285 * = 1: In the CsvFile directory of the SD card 286 286 287 - **The path for offline simulation is: C:\ HMIEmulation\ CustomFileDir\ CsvFile**287 +The path for offline simulation is: C:\ HMIEmulation\ CustomFileDir\ CsvFile 288 288 ))) 289 289 |HSW242|Numerical input object|Returns the results of the csv import:((( 290 290 * = 37: CSV file imported successfully ... ... @@ -306,7 +306,7 @@ 306 306 307 307 * HSW1066=1: Import the normal recipe file of regular series HMI (the data in line 1 of the file is invalid); 308 308 309 -The data in line 1 of the normal recipe file is used to define the format of the recipe and will not be imported into the recipe table as recipe information, **but you must ensure that the data in line 1 representing the elements and number of groups is correct, otherwise the CSV recipe file will fail to be imported.**309 +The data in line 1 of the normal recipe file is used to define the format of the recipe and will not be imported into the recipe table as recipe information, but you must ensure that the data in line 1 representing the elements and number of groups is correct, otherwise the CSV recipe file will fail to be imported. 310 310 311 311 (% style="text-align:center" %) 312 312 [[image:image-20220806101520-6.jpeg]] ... ... @@ -313,36 +313,64 @@ 313 313 314 314 * HSW1066=2: Import the special recipe file of regular series HMI (the data in line 1, 2 and column 1 of the file are invalid); 315 315 316 -In the special recipe file, line 1 is used to define the format of the recipe, line 2 is used to define the element name of the recipe, and column 1 is used to define the group name of the recipe, so lines 1, 2 and column 1 of the special recipe will not be imported into the recipe table as recipe information. **During use, ensure that the data such as the number of groups and elements representing the recipe format in the first line are correct, otherwise the import of the CSV recipe file will fail.**316 +In the special recipe file, line 1 is used to define the format of the recipe, line 2 is used to define the element name of the recipe, and column 1 is used to define the group name of the recipe, so lines 1, 2 and column 1 of the special recipe will not be imported into the recipe table as recipe information. During use, ensure that the data such as the number of groups and elements representing the recipe format in the first line are correct, otherwise the import of the CSV recipe file will fail. 317 317 318 -(% style="text-align:center" %) 319 -[[image:image-20220806102610-7.jpeg]] 320 320 321 -**Perform import** 322 322 323 -After configuring the saving path of CSV recipe file, the name of recipe file and the type of recipe according to the above steps, the method of transferring CSV file to DB file is as follows: 324 324 325 -* Configure the DB recipe file name by text input object: HDW500 = 3 (recipe file configured in Figure 1), 326 -* Set the recipe function address to: HDW1000 = 64 (the function address configured in Figure 1), 327 -* Transform the CSV recipe file in U disk into DB recipe file with file name “3.rcp2”. 321 +(3) Perform import 328 328 329 -**DB recipe file for storing CSV data:** 330 330 331 - Simplemode:When therecipe fileissettosimplemode,thefile ofCSVdataissavedas theDBrecipefile of1.rcp2bydefault.324 + After configuring the saving path of CSV recipe file, the name of recipe file and the type of recipe according to the above steps, the method of transferring CSV file to DB file is as follows: 332 332 333 -Advanced mode: When the recipe is enabled in advanced mode (multi-file recipe), the imported CSV file data is saved to the file recorded at the recipe file address HDW500 (the address configured in Figure 1). 334 334 335 - **Import results:**327 + A) Configure the DB recipe file name by text input object: HDW500 = 3 (recipe file configured in Figure 1), 336 336 337 -* HSW242 = 37: Import succeeded; 338 -* HSW242 = 38: Import failed. 339 339 340 - **Precautions:**330 + B) Set the recipe function address to: HDW1000 = 64 (the function address configured in Figure 1), 341 341 342 -* Ensure that the data format of each element in the CSV file is the same as the recipe data format set in the software (DB), and ensure that the elements of each row in the valid data area is the same as the elements set in the software (DB); 343 -* When the elements of a line in CSV file is more than the elements set in the software (DB), it will prompt the import failure; 344 -* When the CSV file imported into the regular series HMI is a recipe file, the data representing the recipe format (elements, number of groups, whether it is a special recipe) in line 1 must be correct, otherwise the import of CSV file will fail. 345 345 333 + C) Transform the CSV recipe file in U disk into DB recipe file with file name “3.rcp2”. 334 + 335 + 336 +5. DB recipe file for storing CSV data: 337 + 338 + 339 +(1) Simple mode: 340 + 341 + 342 + When the recipe file is set to simple mode, the file of CSV data is saved as the DB recipe file of 1. rcp2 by default. 343 + 344 + 345 +(2) Advanced mode: 346 + 347 + 348 + When the recipe is enabled in advanced mode (multi-file recipe), the imported CSV file data is saved to the file recorded at the recipe file address HDW500 (the address configured in Figure 1). 349 + 350 + 351 +6. Import results: 352 + 353 + 354 +(1) HSW242 = 37: Import succeeded; 355 + 356 + 357 +(2) HSW242 = 38: Import failed. 358 + 359 + 360 + 361 +3. Precautions: 362 + 363 + 364 +~1. Ensure that the data format of each element in the CSV file is the same as the recipe data format set in the software (DB), and ensure that the elements of each row in the valid data area is the same as the elements set in the software (DB); 365 + 366 + 367 +2. When the elements of a line in CSV file is more than the elements set in the software (DB), it will prompt the import failure; 368 + 369 + 370 +3. When the CSV file imported into the regular series HMI is a recipe file, the data representing the recipe format (elements, number of groups, whether it is a special recipe) in line 1 must be correct, otherwise the import of CSV file will fail. 371 + 372 + 373 + 346 346 = (% style="color:inherit; font-family:inherit; font-size:29px" %)**Traditional recipe**(%%) = 347 347 348 348 Traditional recipe is composed of multiple groups of information with the same structure and different data. Due to the similarity of these information, you could edit them into a set of recipes to facilitate the transfer of data between HMI and PLC.
- image-20220806102610-7.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.9 KB - Content