Changes for page 06 Data Tool

Last modified by Jett on 2025/02/18 16:43

From version 26.1
edited by Stone Wu
on 2022/08/06 11:14
Change comment: There is no comment for this version
To version 35.1
edited by Jim
on 2023/08/11 09:44
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Jim
Content
... ... @@ -19,17 +19,20 @@
19 19  
20 20  **Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
21 21  
22 +(% class="box infomessage" %)
23 +(((
22 22  **✎Note:**
23 23  
24 24  * After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
25 25  * The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
26 26  
27 -(% style="margin-left:auto; margin-right:auto; width:358px" %)
29 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:358px" %)
28 28  |=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
29 29  |(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
30 30  |(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
31 31  |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
32 32  |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
35 +)))
33 33  
34 34  **Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
35 35  
... ... @@ -88,6 +88,8 @@
88 88  
89 89  **Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
90 90  
94 +(% class="box infomessage" %)
95 +(((
91 91  **✎Note:**
92 92  
93 93  * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
... ... @@ -99,6 +99,7 @@
99 99  |(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
100 100  |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
101 101  |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
107 +)))
102 102  
103 103  **Record alarm:**  Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location.
104 104  
... ... @@ -179,7 +179,10 @@
179 179  **Basic**
180 180  
181 181  * **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object);
182 -** **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters;
188 +** (% class="box infomessage" %)
189 +(((
190 +**✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters;
191 +)))
183 183  * **Group: **Set the recipe group number, the number of elements, the data format. The data format has 8 modes: 16-bit signed decimal, 16-bit unsigned decimal, 16-bit BCD, 32-bit signed decimal, 32-bit unsigned decimal, 16-bit BCD, 32-bit floating point number, 64-bit (double-precision) floating-point number, string, and the choice of data integer and decimal places.
184 184  * **Elements:** It sets members' initial number of each group;
185 185  * **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form;
... ... @@ -242,7 +242,7 @@
242 242  )))
243 243  
244 244  
245 -**description of Adcanced mode**
254 +**Description of adcanced mode**
246 246  
247 247  According to the recipe configuration information in Figure 2 above. The function address is HDW70, and each function configuration corresponds to the group number address, recipe element address and recipe file name address. The recipe information configured in figure 2 can be displayed in the table in figure 3 with the "Record Display" object.
248 248  
... ... @@ -689,7 +689,10 @@
689 689  
690 690  (% class="box infomessage" %)
691 691  (((
692 -✎**Note: **The user name and password must be unique.
701 +✎**Note: **
702 +
703 +* The user name and password must be unique.
704 +* The multi language function of User permission only supported on HMI system version V2.0 or above
693 693  )))
694 694  
695 695  == Settings ==
... ... @@ -699,6 +699,11 @@
699 699  (% style="text-align:center" %)
700 700  [[image:用户权限 1.png||class="img-thumbnail"]]
701 701  
714 +Click on the cell from UserName and Desc, which can support the multi language.
715 +
716 +(% style="text-align:center" %)
717 +[[image:UserPermissionMultilan.png]]
718 +
702 702  1. Click "User Permission" in "Data Tool" toolbar.
703 703  1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users.
704 704  1. Edit password, click "User0" cell under "PassWord", and then enter the user name.
... ... @@ -712,6 +712,9 @@
712 712  * Only a maximum of one administrator permission is allowed in a profile with one user permission. If you want to use "Funtion address" to modify the user permission, you must log in the administrator account to operate.
713 713  * When the configured file does not have the administrator account, a new user can be added  through "Funtion address" and set as the administrator.
714 714  * If you select hidden fucntion when configuring user account, the account would display as "~*~*~*~*~*~*" in the list. You only need to enter the password of the corresponding hidden user to log in.
732 +* (((
733 +Adding new UserName and Desc on the HMI by special addresses in the current language of the HMI, other languages will also configure the user names and user descriptions to the current language by default, i.e. switching to other languages, the new user names and user descriptions will not change with the language.
734 +)))
715 715  
716 716  == Object permission configuration ==
717 717  
... ... @@ -718,6 +718,11 @@
718 718  (% style="text-align:center" %)
719 719  [[image:用户权限 2.png||class="img-thumbnail"]]
720 720  
741 +User operation logs support multi languages configuration. Click on the Log Message, the text editor of multi language will be pop up:
742 +
743 +(% style="text-align:center" %)
744 +[[image:LogMessagesMultilan.png]]
745 +
721 721  **Operation Procedure of Object Permission**
722 722  
723 723  1. Open the object setting windows;
... ... @@ -861,11 +861,14 @@
861 861  (For both username and password, it can not repetition)
862 862  )))
863 863  
889 +(% class="box infomessage" %)
890 +(((
864 864  **✎Note:**
865 865  
866 866  * *1: If there is an admin user account, then the new user can no longer add one more admin, that is, one project can only have one administrator account.
867 867  * *1: When adding new user, the password could not be duplicated with other users.
868 868  * *2: When deleting user, it is forbidden to delete the admin user.
896 +)))
869 869  
870 870  **User Permission Demo Download**
871 871  
... ... @@ -907,11 +907,14 @@
907 907  
908 908  User deletes default content or modifies default content, but he wants to give up modification back to original, just click "Reload text".
909 909  
938 +(% class="box infomessage" %)
939 +(((
910 910  **✎Note:**
911 911  
912 912  * If you do not want this prompt during the running of HMI, please uncheck "Show message".
913 913  * "Reload text" function would be invalid after clicking "save".
914 914  * These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&".
945 +)))
915 915  
916 916  = **Cloud** =
917 917  
LogMessagesMultilan.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +37.5 KB
Content
UserPermissionMultilan.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +23.2 KB
Content