... ... @@ -19,23 +19,21 @@
19 19  
20 20  **Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
21 21  
22 +(% class="box infomessage" %)
23 +(((
22 22  **✎Note:**
23 23  
24 24  * After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
25 25  * The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
26 26  
27 -(% style="margin-left:auto; margin-right:auto; width:358px" %)
29 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:358px" %)
28 28  |=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
29 29  |(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
30 30  |(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
31 31  |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
32 32  |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
35 +)))
33 33  
34 -(% class="table-bordered" style="margin-left:auto; margin-right:auto" %)
35 -|= |=
36 -| |
37 -| |
38 -
39 39  **Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
40 40  
41 41  **Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
... ... @@ -93,6 +93,8 @@
93 93  
94 94  **Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
95 95  
94 +(% class="box infomessage" %)
95 +(((
96 96  **✎Note:**
97 97  
98 98  * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
... ... @@ -104,6 +104,7 @@
104 104  |(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
105 105  |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
106 106  |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
107 +)))
107 107  
108 108  **Record alarm:**  Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location.