Changes for page 06 Data Tool

Last modified by Jett on 2025/02/18 16:43

From version 3.1
edited by Joey
on 2022/06/16 14:56
Change comment: There is no comment for this version
To version 3.3
edited by Stone Wu
on 2022/06/30 11:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Joey
1 +XWiki.Stone
Content
... ... @@ -1,9 +1,9 @@
1 1  (% class="wikigeneratedid" id="H8BasicFunction" %)
2 -This chapter provides information about basic functions and configiration in PIStudio.
2 +This chapter provides information about basic functions and configuration in PIStudio.
3 3  
4 4  = **{{id name="_Toc28532"/}}Alarm** =
5 5  
6 -== **Bit Alarm** ==
6 +== **Bit alarm** ==
7 7  
8 8  Click "Project"->"Bit alarm", it is displayed as the following figure.
9 9  
... ... @@ -18,7 +18,7 @@
18 18  1. **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
19 19  1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
20 20  
21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud aand it is alarm data. (Only ig supported)
21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
22 22  
23 23  **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
24 24  
... ... @@ -37,7 +37,7 @@
37 37  
38 38  **✎Note:**
39 39  
40 -* If the "cloud" function is enabled and "upload to cloud" is checked, the communnication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
40 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
41 41  * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure.
42 42  
43 43  **Operating Procedures of Adding One Alarm**
... ... @@ -64,7 +64,7 @@
64 64  
65 65  Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated.
66 66  
67 -Click "Porject"->"Word alarm", it is displayed as the following figure.
67 +Click "Project"->"Word alarm", it is displayed as the following figure.
68 68  
69 69  (% style="text-align:center" %)
70 70  [[image:字报警 1.png||class="img-thumbnail"]]
... ... @@ -77,11 +77,11 @@
77 77  
78 78  **(4)  Group No.: **Group number of word alarm. The name is unique and cannot be duplicated.
79 79  
80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud aand it is alarm data. (Only ig supported)
80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
81 81  
82 82  **✎Note:**
83 83  
84 -* If the "cloud" function is enabled and "upload to cloud" is checked, the communnication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
84 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
85 85  * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure.
86 86  
87 87  **(6) Record alarm:**  Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location.
... ... @@ -150,7 +150,7 @@
150 150  
151 151  The maximum number of group in recipe is 1000, and the maximum number of member in each group is 1500.
152 152  
153 -Recipe could store the data in USB flash disk and SD card and view the recipe data by obejct "Recipe display". It has two mode: simple mode and advanced mode.
153 +Recipe could store the data in USB flash disk and SD card and view the recipe data by object "Recipe display". It has two mode: simple mode and advanced mode.
154 154  
155 155  1. **Simple: **Only support the data operation of one recipe file, including read and write.
156 156  1. **Advanced:** Support the data operation of multiple recipe files, including read, write, insert and index. View and select recipe file by object "File list".
... ... @@ -273,9 +273,9 @@
273 273  
274 274  == **Recipe display** ==
275 275  
276 -Select the file type "Traditional recipe file" in onject "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.
276 +Select the file type "Traditional recipe file" in object "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.
277 277  
278 -**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as follwoing shown:
278 +**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as following shown:
279 279  
280 280  (% style="text-align:center" %)
281 281  [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]]