Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
From version 3.1
edited by Joey
on 2022/06/16 14:56
on 2022/06/16 14:56
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Joey1 +XWiki.Stone - Content
-
... ... @@ -1,9 +1,9 @@ 1 1 (% class="wikigeneratedid" id="H8BasicFunction" %) 2 -This chapter provides information about basic functions and config iration in PIStudio.2 +This chapter provides information about basic functions and configuration in PIStudio. 3 3 4 4 = **{{id name="_Toc28532"/}}Alarm** = 5 5 6 -== **Bit Alarm** ==6 +== **Bit alarm** == 7 7 8 8 Click "Project"->"Bit alarm", it is displayed as the following figure. 9 9 ... ... @@ -18,7 +18,7 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud a and it is alarm data. (Only ig supported)21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 22 22 23 23 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 24 24 ... ... @@ -37,7 +37,7 @@ 37 37 38 38 **✎Note:** 39 39 40 -* If the "cloud" function is enabled and "upload to cloud" is checked, the commun nication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally.40 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 41 41 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 42 42 43 43 **Operating Procedures of Adding One Alarm** ... ... @@ -64,7 +64,7 @@ 64 64 65 65 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 66 66 67 -Click "P orject"->"Word alarm", it is displayed as the following figure.67 +Click "Project"->"Word alarm", it is displayed as the following figure. 68 68 69 69 (% style="text-align:center" %) 70 70 [[image:字报警 1.png||class="img-thumbnail"]] ... ... @@ -77,11 +77,11 @@ 77 77 78 78 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 79 79 80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud a and it is alarm data. (Only ig supported)80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 81 81 82 82 **✎Note:** 83 83 84 -* If the "cloud" function is enabled and "upload to cloud" is checked, the commun nication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.84 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 85 85 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 86 86 87 87 **(6) Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. ... ... @@ -150,7 +150,7 @@ 150 150 151 151 The maximum number of group in recipe is 1000, and the maximum number of member in each group is 1500. 152 152 153 -Recipe could store the data in USB flash disk and SD card and view the recipe data by ob ejct "Recipe display". It has two mode: simple mode and advanced mode.153 +Recipe could store the data in USB flash disk and SD card and view the recipe data by object "Recipe display". It has two mode: simple mode and advanced mode. 154 154 155 155 1. **Simple: **Only support the data operation of one recipe file, including read and write. 156 156 1. **Advanced:** Support the data operation of multiple recipe files, including read, write, insert and index. View and select recipe file by object "File list". ... ... @@ -273,9 +273,9 @@ 273 273 274 274 == **Recipe display** == 275 275 276 -Select the file type "Traditional recipe file" in o nject "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.276 +Select the file type "Traditional recipe file" in object "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line. 277 277 278 -**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as foll woing shown:278 +**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as following shown: 279 279 280 280 (% style="text-align:center" %) 281 281 [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]] ... ... @@ -366,7 +366,7 @@ 366 366 367 367 **(1) Basic settings** 368 368 369 -1. **Curve NO.: **It is for setting curvenumber, 369 +1. **Curve NO.: **It is for setting curve number, 370 370 1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes. 371 371 1. **Curve (1~~8):** It is for setting the number of curves. The default is 3. 372 372 1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves. ... ... @@ -373,7 +373,7 @@ 373 373 374 374 **(2) Sample Type** 375 375 376 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.376 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit. 377 377 1. **Sample unit:** 100ms. 378 378 379 379 **(3) Quick Setting** ... ... @@ -384,7 +384,7 @@ 384 384 [[image:趋势图设置 3.png||class="img-thumbnail"]] 385 385 386 386 (% start="2" %) 387 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 387 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 388 388 389 389 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 390 390 ... ... @@ -408,7 +408,7 @@ 408 408 409 409 **(1) Basic settings** 410 410 411 -1. **Curve NO.: **It is for setting curvenumber, 411 +1. **Curve NO.: **It is for setting curve number, 412 412 1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes. 413 413 1. **Curve (1~~8):** It is for setting the number of curves. The default is 3. 414 414 1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves. ... ... @@ -415,7 +415,7 @@ 415 415 416 416 **(2) Sample Type** 417 417 418 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.418 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit. 419 419 1. **Sample unit:** 100ms. 420 420 421 421 **(3) Quick Setting** ... ... @@ -426,7 +426,7 @@ 426 426 [[image:image-20220616145435-1.png]] 427 427 428 428 (% start="2" %) 429 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 429 +1. **Sample address: **Fill in the start address that read the device data. If the sample address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 430 430 431 431 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 432 432