Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -366,7 +366,7 @@ 366 366 367 367 **(1) Basic settings** 368 368 369 -1. **Curve NO.: **It is for setting curvenumber, 369 +1. **Curve NO.: **It is for setting curve number, 370 370 1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes. 371 371 1. **Curve (1~~8):** It is for setting the number of curves. The default is 3. 372 372 1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves. ... ... @@ -373,7 +373,7 @@ 373 373 374 374 **(2) Sample Type** 375 375 376 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.376 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit. 377 377 1. **Sample unit:** 100ms. 378 378 379 379 **(3) Quick Setting** ... ... @@ -384,7 +384,7 @@ 384 384 [[image:趋势图设置 3.png||class="img-thumbnail"]] 385 385 386 386 (% start="2" %) 387 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 387 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 388 388 389 389 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 390 390 ... ... @@ -408,7 +408,7 @@ 408 408 409 409 **(1) Basic settings** 410 410 411 -1. **Curve NO.: **It is for setting curvenumber, 411 +1. **Curve NO.: **It is for setting curve number, 412 412 1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes. 413 413 1. **Curve (1~~8):** It is for setting the number of curves. The default is 3. 414 414 1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves. ... ... @@ -415,7 +415,7 @@ 415 415 416 416 **(2) Sample Type** 417 417 418 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.418 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit. 419 419 1. **Sample unit:** 100ms. 420 420 421 421 **(3) Quick Setting** ... ... @@ -426,7 +426,7 @@ 426 426 [[image:image-20220616145435-1.png]] 427 427 428 428 (% start="2" %) 429 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 429 +1. **Sample address: **Fill in the start address that read the device data. If the sample address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 430 430 431 431 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 432 432 ... ... @@ -463,7 +463,7 @@ 463 463 464 464 The data record stored in SD card is also organized according to the above figure. 465 465 466 -The sample time and save time is consistent in the same recor ed group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.466 +The sample time and save time is consistent in the same record group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address. 467 467 468 468 **Sampling interval: **The interval between two consecutive samples was recorded. 469 469 ... ... @@ -511,7 +511,7 @@ 511 511 1. **Trigger to record by sample cycle: **Data will be recorded in every same time, when trigger control bit set ON. 512 512 1. **Trigger to record once and reset: **Data will be recorded when trigger control bit set ON, and the bit will be reset automatically. 513 513 1. **Trigger to record once: **Data will be recorded when trigger control bit set ON, and the bit need to be reset manually. 514 -1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycl ce for trigger sampling address is 1s.514 +1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycle for trigger sampling address is 1s. 515 515 516 516 **(3) Total channels (1~~100): **Set the numbers of channels. Click "apply" to view the channel lists on the right record channel. 517 517 ... ... @@ -527,8 +527,8 @@ 527 527 528 528 **(7) Quick Settings** 529 529 530 -1. **Start Channel:** It sets the continuous addressesfor channels. 531 -1. **Data Format: **It setsthe samedata format for channels. 530 +1. **Start Channel:** It sets the continuous addresses for channels. 531 +1. **Data Format: **It sets the same data format for channels. 532 532 1. **Number of Digits:** It sets the digits’ number for channels. 533 533 1. **Language Settings**: The text in HMI can be in 8 languages, user can set language in here. 534 534 ... ... @@ -570,7 +570,7 @@ 570 570 [[image:用户权限 1.png||class="img-thumbnail"]] 571 571 572 572 1. Click "User Permission" in "Data Tool" toolbar. 573 -1. Edit user name, click "User0" cellunder "UserName", and then enter the user name, one project allows maximum 20 users. 573 +1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users. 574 574 1. Edit password, click "User0" cell under "PassWord", and then enter the user name. 575 575 1. Edit description, click "User0" cell under "Desc", and then enter, description is not necessary。 576 576 1. Check the groups for each user, there are 11 groups beside admin. ... ... @@ -597,7 +597,7 @@ 597 597 1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded; 598 598 1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode; 599 599 600 -**Log i mformation description**600 +**Log information description** 601 601 602 602 1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 603 603 1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.