Changes for page 06 Data Tool

Last modified by Jett on 2025/02/18 16:43

From version 3.3
edited by Stone Wu
on 2022/06/30 11:33
Change comment: There is no comment for this version
To version 4.1
edited by Stone Wu
on 2022/06/30 11:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -366,7 +366,7 @@
366 366  
367 367  **(1) Basic settings**
368 368  
369 -1. **Curve NO.: **It is for setting curvenumber,
369 +1. **Curve NO.: **It is for setting curve number,
370 370  1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes.
371 371  1. **Curve (1~~8):** It is for setting the number of curves. The default is 3.
372 372  1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves.
... ... @@ -373,7 +373,7 @@
373 373  
374 374  **(2) Sample Type**
375 375  
376 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.
376 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit.
377 377  1. **Sample unit:** 100ms.
378 378  
379 379  **(3) Quick Setting**
... ... @@ -384,7 +384,7 @@
384 384  [[image:趋势图设置 3.png||class="img-thumbnail"]]
385 385  
386 386  (% start="2" %)
387 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
387 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
388 388  
389 389  **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content.
390 390  
... ... @@ -408,7 +408,7 @@
408 408  
409 409  **(1) Basic settings**
410 410  
411 -1. **Curve NO.: **It is for setting curvenumber,
411 +1. **Curve NO.: **It is for setting curve number,
412 412  1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes.
413 413  1. **Curve (1~~8):** It is for setting the number of curves. The default is 3.
414 414  1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves.
... ... @@ -415,7 +415,7 @@
415 415  
416 416  **(2) Sample Type**
417 417  
418 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit.
418 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit.
419 419  1. **Sample unit:** 100ms.
420 420  
421 421  **(3) Quick Setting**
... ... @@ -426,7 +426,7 @@
426 426  [[image:image-20220616145435-1.png]]
427 427  
428 428  (% start="2" %)
429 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
429 +1. **Sample address: **Fill in the start address that read the device data. If the sample address is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.
430 430  
431 431  **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content.
432 432  
... ... @@ -463,7 +463,7 @@
463 463  
464 464  The data record stored in SD card is also organized according to the above figure.
465 465  
466 -The sample time and save time is consistent in the same recored group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.
466 +The sample time and save time is consistent in the same record group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.
467 467  
468 468  **Sampling interval: **The interval between two consecutive samples was recorded.
469 469  
... ... @@ -511,7 +511,7 @@
511 511  1. **Trigger to record by sample cycle: **Data will be recorded in every same time, when trigger control bit set ON.
512 512  1. **Trigger to record once and reset: **Data will be recorded when trigger control bit set ON, and the bit will be reset automatically.
513 513  1. **Trigger to record once: **Data will be recorded when trigger control bit set ON, and the bit need to be reset manually.
514 -1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cyclce for trigger sampling address is 1s.
514 +1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycle for trigger sampling address is 1s.
515 515  
516 516  **(3) Total channels (1~~100): **Set the numbers of channels. Click "apply" to view the channel lists on the right record channel.
517 517  
... ... @@ -527,8 +527,8 @@
527 527  
528 528  **(7) Quick Settings**
529 529  
530 -1. **Start Channel:** It sets the continuous addressesfor channels.
531 -1. **Data Format: **It setsthe samedata format for channels.
530 +1. **Start Channel:** It sets the continuous addresses for channels.
531 +1. **Data Format: **It sets the same data format for channels.
532 532  1. **Number of Digits:** It sets the digits’ number for channels.
533 533  1. **Language Settings**: The text in HMI can be in 8 languages, user can set language in here.
534 534  
... ... @@ -570,7 +570,7 @@
570 570  [[image:用户权限 1.png||class="img-thumbnail"]]
571 571  
572 572  1. Click "User Permission" in "Data Tool" toolbar.
573 -1. Edit user name, click "User0" cellunder "UserName", and then enter the user name, one project allows maximum 20 users.
573 +1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users.
574 574  1. Edit password, click "User0" cell under "PassWord", and then enter the user name.
575 575  1. Edit description, click "User0" cell under "Desc", and then enter, description is not necessary。
576 576  1. Check the groups for each user, there are 11 groups beside admin.
... ... @@ -597,7 +597,7 @@
597 597  1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded;
598 598  1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode;
599 599  
600 -**Log imformation description**
600 +**Log information description**
601 601  
602 602  1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
603 603  1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
... ... @@ -762,7 +762,7 @@
762 762  
763 763  **For Example:**
764 764  
765 -Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
765 +Trigger address is 011, during inserting a USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
766 766  
767 767  1. **Show message: **Check it to display message when HMI is running. It is checked by default.
768 768  1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default.
... ... @@ -781,7 +781,7 @@
781 781  
782 782  * If you do not want this prompt during the running of HMI, please uncheck "Show message".
783 783  * "Reload text" function would be invalid after clicking "save".
784 -* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&".
784 +* These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&".
785 785  
786 786  = **Cloud (Only ig series)** =
787 787  
... ... @@ -824,45 +824,3 @@
824 824  
825 825  1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default.
826 826  1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags.
827 -
828 -= **Cloud (Only ig series)** =
829 -
830 -**Introduction**
831 -
832 -You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
833 -
834 -Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
835 -
836 -(% style="text-align:center" %)
837 -[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]]
838 -
839 -**(1) Enable**
840 -
841 -If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
842 -
843 -1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
844 -1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.4AlarmRecord]] for details)
845 -1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.3DataRecord]])
846 -
847 -**{{id name="_GoBack"/}}(2) Server Selection**
848 -
849 - **Server**: China, ASEAN, and Europe.
850 -
851 - **Password**:
852 -
853 -1. If the HMI is not bound, this access password will be updated and downloaded into the HMI screen simultaneously.
854 -1. If the HMI is bound, this access password in the project cannot effectively change the binding password of the device, and it can only be changed through V-NET.
855 -
856 -**(3) Upload Selection**: 
857 -
858 -To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected.
859 -
860 -1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET.
861 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to [[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#H10.19CloudInterface]].
862 -
863 -After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally.
864 -
865 -**4) Low Data Mode setting**
866 -
867 -1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default.
868 -1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags.