Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Hunter - Content
-
... ... @@ -1,7 +1,7 @@ 1 1 (% class="wikigeneratedid" id="H8BasicFunction" %) 2 2 This chapter provides information about basic functions and configuration in PIStudio. 3 3 4 -= ** {{id name="_Toc28532"/}}Alarm** =4 += **Alarm** = 5 5 6 6 == **Bit alarm** == 7 7 ... ... @@ -18,7 +18,7 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series after system upgrade are supported) 22 22 23 23 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 24 24 ... ... @@ -60,7 +60,7 @@ 60 60 1. Other settings can be set according to the actual situation". 61 61 1. Click "OK" button to complete settings. 62 62 63 -== ** {{id name="_Toc5343"/}}{{id name="_Word_alarm"/}}WordAlarm** ==63 +== **Word Alarm** == 64 64 65 65 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 66 66 ... ... @@ -463,7 +463,7 @@ 463 463 464 464 The data record stored in SD card is also organized according to the above figure. 465 465 466 -The sample time and save time is consistent in the same recor ed group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.466 +The sample time and save time is consistent in the same record group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address. 467 467 468 468 **Sampling interval: **The interval between two consecutive samples was recorded. 469 469 ... ... @@ -511,7 +511,7 @@ 511 511 1. **Trigger to record by sample cycle: **Data will be recorded in every same time, when trigger control bit set ON. 512 512 1. **Trigger to record once and reset: **Data will be recorded when trigger control bit set ON, and the bit will be reset automatically. 513 513 1. **Trigger to record once: **Data will be recorded when trigger control bit set ON, and the bit need to be reset manually. 514 -1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycl ce for trigger sampling address is 1s.514 +1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycle for trigger sampling address is 1s. 515 515 516 516 **(3) Total channels (1~~100): **Set the numbers of channels. Click "apply" to view the channel lists on the right record channel. 517 517 ... ... @@ -527,8 +527,8 @@ 527 527 528 528 **(7) Quick Settings** 529 529 530 -1. **Start Channel:** It sets the continuous addressesfor channels. 531 -1. **Data Format: **It setsthe samedata format for channels. 530 +1. **Start Channel:** It sets the continuous addresses for channels. 531 +1. **Data Format: **It sets the same data format for channels. 532 532 1. **Number of Digits:** It sets the digits’ number for channels. 533 533 1. **Language Settings**: The text in HMI can be in 8 languages, user can set language in here. 534 534 ... ... @@ -570,7 +570,7 @@ 570 570 [[image:用户权限 1.png||class="img-thumbnail"]] 571 571 572 572 1. Click "User Permission" in "Data Tool" toolbar. 573 -1. Edit user name, click "User0" cellunder "UserName", and then enter the user name, one project allows maximum 20 users. 573 +1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users. 574 574 1. Edit password, click "User0" cell under "PassWord", and then enter the user name. 575 575 1. Edit description, click "User0" cell under "Desc", and then enter, description is not necessary。 576 576 1. Check the groups for each user, there are 11 groups beside admin. ... ... @@ -597,7 +597,7 @@ 597 597 1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded; 598 598 1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode; 599 599 600 -**Log i mformation description**600 +**Log information description** 601 601 602 602 1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 603 603 1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. ... ... @@ -762,7 +762,7 @@ 762 762 763 763 **For Example:** 764 764 765 -Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message. 765 +Trigger address is 011, during inserting a USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message. 766 766 767 767 1. **Show message: **Check it to display message when HMI is running. It is checked by default. 768 768 1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default. ... ... @@ -781,12 +781,14 @@ 781 781 782 782 * If you do not want this prompt during the running of HMI, please uncheck "Show message". 783 783 * "Reload text" function would be invalid after clicking "save". 784 -* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&". 784 +* These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&". 785 785 786 -= **Cloud (Only ig series)** =786 += **Cloud** = 787 787 788 788 **Introduction** 789 789 790 +Cloud function is available for following models: the ig series and 8000/9000 series with -R after system upgrade 791 + 790 790 You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.) 791 791 792 792 Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. ... ... @@ -796,56 +796,24 @@ 796 796 797 797 **(1) Enable** 798 798 799 -If the HMI supports Cloud, select"enable" and"tocloud",then it willuploadthe real-time datasampledby theHMI to thecloud. The number of tagsis limited, the specific parameters are as follows.801 +If the HMI supports the Cloud function, check it to enable the Cloud function, and it will collect the real-time data from HMI upload to the Cloud. The number of data collection is limited, and the specific parameters are as follows: 800 800 801 -1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100. 802 -1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 803 -1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 803 +|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data 804 +|8000-R|300|200|100|1000 805 +|9000-R|300|200|100|1000 806 +|3000ig|100|20|50|500 807 +|8000ig|300|200|100|1000 804 804 805 - **{{id name="_GoBack"/}}(2) ServerSelection**809 +For example: 806 806 807 - **Server**:China,ASEAN,andEurope.811 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100. 808 808 809 - **Password**:813 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 810 810 811 -1. If the HMI is not bound, this access password will be updated and downloaded into the HMI screen simultaneously. 812 -1. If the HMI is bound, this access password in the project cannot effectively change the binding password of the device, and it can only be changed through V-NET. 815 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 813 813 814 -**( 3)UploadSelection**:817 +**(2) Server Selection** 815 815 816 -To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected. 817 - 818 -1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET. 819 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]". 820 - 821 -After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally. 822 - 823 -**4) Low Data Mode setting** 824 - 825 -1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default. 826 -1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags. 827 - 828 -= **Cloud (Only ig series)** = 829 - 830 -**Introduction** 831 - 832 -You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.) 833 - 834 -Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. 835 - 836 -(% style="text-align:center" %) 837 -[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]] 838 - 839 -**(1) Enable** 840 - 841 -If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows. 842 - 843 -1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100. 844 -1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.4AlarmRecord]] for details) 845 -1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.3DataRecord]]) 846 - 847 -**{{id name="_GoBack"/}}(2) Server Selection** 848 - 849 849 **Server**: China, ASEAN, and Europe. 850 850 851 851 **Password**: ... ... @@ -858,7 +858,7 @@ 858 858 To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected. 859 859 860 860 1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET. 861 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to 10.19CloudInterface]].831 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]". 862 862 863 863 After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally. 864 864