... ... @@ -1,11 +1,11 @@
1 1  (% class="wikigeneratedid" id="H8BasicFunction" %)
2 2  This chapter provides information about basic functions and configuration in PIStudio.
3 3  
4 -= **{{id name="_Toc28532"/}}Alarm** =
4 += **Alarm** =
5 5  
6 -== **Bit alarm** ==
6 +== **Bit Alarm** ==
7 7  
8 -Click "Project"->"Bit alarm", it is displayed as the following figure.
8 +Click "Project"->"Bit Alarm", it is displayed as the following figure.
9 9  
10 10  (% style="text-align:center" %)
11 11  [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]]
... ... @@ -18,8 +18,20 @@
18 18  1. **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
19 19  1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
20 20  
21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
22 22  
23 +**✎Note:**
24 +
25 +* After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
26 +* The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
27 +
28 +(% style="margin-left:auto; margin-right:auto; width:358px" %)
29 +|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
30 +|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
31 +|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
32 +|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
33 +|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
34 +
23 23  **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
24 24  
25 25  **(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
... ... @@ -60,7 +60,7 @@
60 60  1. Other settings can be set according to the actual situation".
61 61  1. Click "OK" button to complete settings.
62 62  
63 -== **{{id name="_Toc5343"/}}{{id name="_Word_alarm"/}}Word Alarm** ==
75 +== **Word Alarm** ==
64 64  
65 65  Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated.
66 66  
... ... @@ -77,7 +77,7 @@
77 77  
78 78  **(4)  Group No.: **Group number of word alarm. The name is unique and cannot be duplicated.
79 79  
80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
92 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
81 81  
82 82  **✎Note:**
83 83  
... ... @@ -84,6 +84,13 @@
84 84  * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
85 85  * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure.
86 86  
99 +(% style="margin-left:auto; margin-right:auto; width:358px" %)
100 +|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
101 +|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
102 +|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
103 +|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
104 +|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
105 +
87 87  **(6) Record alarm:**  Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location.
88 88  
89 89  **(7) Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
... ... @@ -471,8 +471,17 @@
471 471  
472 472  For the file storage of data, see the file size configuration during data record configuration.
473 473  
474 -✎**Note: **The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.
493 +✎**Note: **
475 475  
495 +1)
496 +
497 +2)
498 +
499 +3) The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.
500 +
501 +4) Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ".
502 +
503 +
476 476  (% class="wikigeneratedid" id="HSettings" %)
477 477  **Settings**
478 478  
... ... @@ -762,7 +762,7 @@
762 762  
763 763  **For Example:**
764 764  
765 -Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
793 +Trigger address is 011, during inserting a USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
766 766  
767 767  1. **Show message: **Check it to display message when HMI is running. It is checked by default.
768 768  1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default.
... ... @@ -781,12 +781,14 @@
781 781  
782 782  * If you do not want this prompt during the running of HMI, please uncheck "Show message".
783 783  * "Reload text" function would be invalid after clicking "save".
784 -* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&".
812 +* These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&".
785 785  
786 -= **Cloud (Only ig series)** =
814 += **Cloud** =
787 787  
788 788  **Introduction**
789 789  
818 +Cloud function is available for following models: the ig series and 8000/9000 series with -R after system upgrade
819 +
790 790  You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
791 791  
792 792  Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
... ... @@ -796,56 +796,24 @@
796 796  
797 797  **(1) Enable**
798 798  
799 -If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
829 +If the HMI supports the Cloud function, check it to enable the Cloud function, and it will collect the real-time data from HMI upload to the Cloud. The number of data collection is limited, and the specific parameters are as follows:
800 800  
801 -1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
802 -1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
803 -1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
831 +|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data
832 +|8000-R|300|200|100|1000
833 +|9000-R|300|200|100|1000
834 +|3000ig|100|20|50|500
835 +|8000ig|300|200|100|1000
804 804  
805 -**{{id name="_GoBack"/}}(2) Server Selection**
837 +For example:
806 806  
807 - **Server**: China, ASEAN, and Europe.
839 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
808 808  
809 - **Password**:
841 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
810 810  
811 -1. If the HMI is not bound, this access password will be updated and downloaded into the HMI screen simultaneously.
812 -1. If the HMI is bound, this access password in the project cannot effectively change the binding password of the device, and it can only be changed through V-NET.
843 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
813 813  
814 -**(3) Upload Selection**
845 +**(2) Server Selection**
815 815  
816 -To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected.
817 -
818 -1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET.
819 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".
820 -
821 -After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally.
822 -
823 -**4) Low Data Mode setting**
824 -
825 -1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default.
826 -1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags.
827 -
828 -= **Cloud (Only ig series)** =
829 -
830 -**Introduction**
831 -
832 -You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
833 -
834 -Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
835 -
836 -(% style="text-align:center" %)
837 -[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]]
838 -
839 -**(1) Enable**
840 -
841 -If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
842 -
843 -1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
844 -1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.4AlarmRecord]] for details)
845 -1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.3DataRecord]])
846 -
847 -**{{id name="_GoBack"/}}(2) Server Selection**
848 -
849 849   **Server**: China, ASEAN, and Europe.
850 850  
851 851   **Password**:
... ... @@ -858,7 +858,7 @@
858 858  To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected.
859 859  
860 860  1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET.
861 -1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to [[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#H10.19CloudInterface]].
859 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to "[[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#HCloudInterface]]".
862 862  
863 863  After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally.
864 864