... ... @@ -463,7 +463,7 @@
463 463  
464 464  The data record stored in SD card is also organized according to the above figure.
465 465  
466 -The sample time and save time is consistent in the same record group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.
466 +The sample time and save time is consistent in the same recored group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address.
467 467  
468 468  **Sampling interval: **The interval between two consecutive samples was recorded.
469 469  
... ... @@ -511,7 +511,7 @@
511 511  1. **Trigger to record by sample cycle: **Data will be recorded in every same time, when trigger control bit set ON.
512 512  1. **Trigger to record once and reset: **Data will be recorded when trigger control bit set ON, and the bit will be reset automatically.
513 513  1. **Trigger to record once: **Data will be recorded when trigger control bit set ON, and the bit need to be reset manually.
514 -1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycle for trigger sampling address is 1s.
514 +1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cyclce for trigger sampling address is 1s.
515 515  
516 516  **(3) Total channels (1~~100): **Set the numbers of channels. Click "apply" to view the channel lists on the right record channel.
517 517  
... ... @@ -527,8 +527,8 @@
527 527  
528 528  **(7) Quick Settings**
529 529  
530 -1. **Start Channel:** It sets the continuous addresses for channels.
531 -1. **Data Format: **It sets the same data format for channels.
530 +1. **Start Channel:** It sets the continuous addressesfor channels.
531 +1. **Data Format: **It setsthe samedata format for channels.
532 532  1. **Number of Digits:** It sets the digits’ number for channels.
533 533  1. **Language Settings**: The text in HMI can be in 8 languages, user can set language in here.
534 534  
... ... @@ -570,7 +570,7 @@
570 570  [[image:用户权限 1.png||class="img-thumbnail"]]
571 571  
572 572  1. Click "User Permission" in "Data Tool" toolbar.
573 -1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users.
573 +1. Edit user name, click "User0" cellunder "UserName", and then enter the user name, one project allows maximum 20 users.
574 574  1. Edit password, click "User0" cell under "PassWord", and then enter the user name.
575 575  1. Edit description, click "User0" cell under "Desc", and then enter, description is not necessary。
576 576  1. Check the groups for each user, there are 11 groups beside admin.
... ... @@ -597,7 +597,7 @@
597 597  1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded;
598 598  1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode;
599 599  
600 -**Log information description**
600 +**Log imformation description**
601 601  
602 602  1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63.
603 603  1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}.
... ... @@ -762,7 +762,7 @@
762 762  
763 763  **For Example:**
764 764  
765 -Trigger address is 011, during inserting a USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
765 +Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message.
766 766  
767 767  1. **Show message: **Check it to display message when HMI is running. It is checked by default.
768 768  1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default.
... ... @@ -781,7 +781,7 @@
781 781  
782 782  * If you do not want this prompt during the running of HMI, please uncheck "Show message".
783 783  * "Reload text" function would be invalid after clicking "save".
784 -* These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&".
784 +* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&".
785 785  
786 786  = **Cloud (Only ig series)** =