Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.Stone - Content
-
... ... @@ -19,20 +19,17 @@ 19 19 20 20 **Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 21 21 22 -(% class="box infomessage" %) 23 -((( 24 24 **✎Note:** 25 25 26 26 * After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 27 27 * The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 28 28 29 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:358px" %)27 +(% style="margin-left:auto; margin-right:auto; width:358px" %) 30 30 |=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 31 31 |(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 32 32 |(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 33 33 |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 34 34 |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 35 -))) 36 36 37 37 **Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 38 38 ... ... @@ -91,8 +91,6 @@ 91 91 92 92 **Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 93 93 94 -(% class="box infomessage" %) 95 -((( 96 96 **✎Note:** 97 97 98 98 * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. ... ... @@ -104,7 +104,6 @@ 104 104 |(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 105 105 |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 106 106 |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 107 -))) 108 108 109 109 **Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. 110 110 ... ... @@ -695,10 +695,7 @@ 695 695 696 696 (% class="box infomessage" %) 697 697 ((( 698 -✎**Note: ** 699 - 700 -* The user name and password must be unique. 701 -* The multi language function of User permission only supported on HMI system version V2.0 or above 692 +✎**Note: **The user name and password must be unique. 702 702 ))) 703 703 704 704 == Settings == ... ... @@ -708,11 +708,6 @@ 708 708 (% style="text-align:center" %) 709 709 [[image:用户权限 1.png||class="img-thumbnail"]] 710 710 711 -Click on the cell from UserName and Desc, which can support the multi language. 712 - 713 -(% style="text-align:center" %) 714 -[[image:UserPermissionMultilan.png]] 715 - 716 716 1. Click "User Permission" in "Data Tool" toolbar. 717 717 1. Edit user name, click "User0" cell under "UserName", and then enter the user name, one project allows maximum 20 users. 718 718 1. Edit password, click "User0" cell under "PassWord", and then enter the user name. ... ... @@ -726,9 +726,6 @@ 726 726 * Only a maximum of one administrator permission is allowed in a profile with one user permission. If you want to use "Funtion address" to modify the user permission, you must log in the administrator account to operate. 727 727 * When the configured file does not have the administrator account, a new user can be added through "Funtion address" and set as the administrator. 728 728 * If you select hidden fucntion when configuring user account, the account would display as "~*~*~*~*~*~*" in the list. You only need to enter the password of the corresponding hidden user to log in. 729 -* ((( 730 -Adding new UserName and Desc on the HMI by special addresses in the current language of the HMI, other languages will also configure the user names and user descriptions to the current language by default, i.e. switching to other languages, the new user names and user descriptions will not change with the language. 731 -))) 732 732 733 733 == Object permission configuration == 734 734 ... ... @@ -735,11 +735,6 @@ 735 735 (% style="text-align:center" %) 736 736 [[image:用户权限 2.png||class="img-thumbnail"]] 737 737 738 -User operation logs support multi languages configuration. Click on the Log Message, the text editor of multi language will be pop up: 739 - 740 -(% style="text-align:center" %) 741 -[[image:LogMessagesMultilan.png]] 742 - 743 743 **Operation Procedure of Object Permission** 744 744 745 745 1. Open the object setting windows;
- LogMessagesMultilan.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -37.5 KB - Content
- UserPermissionMultilan.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.2 KB - Content