Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -91,8 +91,6 @@ 91 91 92 92 **Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 93 93 94 -(% class="box infomessage" %) 95 -((( 96 96 **✎Note:** 97 97 98 98 * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. ... ... @@ -104,7 +104,6 @@ 104 104 |(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 105 105 |(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 106 106 |(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 107 -))) 108 108 109 109 **Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. 110 110 ... ... @@ -185,10 +185,7 @@ 185 185 **Basic** 186 186 187 187 * **Recipe Folder:** Give Recipe folder name (It can be used, when setting Recipe display object); 188 -** (% class="box infomessage" %) 189 -((( 190 -**✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters; 191 -))) 185 +** **✎Note: **Recipe Folder name can only consist of (0~~9), (a~~z), (A~~Z), ('_'), (' ') and other non-English characters; 192 192 * **Group: **Set the recipe group number, the number of elements, the data format. The data format has 8 modes: 16-bit signed decimal, 16-bit unsigned decimal, 16-bit BCD, 32-bit signed decimal, 32-bit unsigned decimal, 16-bit BCD, 32-bit floating point number, 64-bit (double-precision) floating-point number, string, and the choice of data integer and decimal places. 193 193 * **Elements:** It sets members' initial number of each group; 194 194 * **Data Format:** There are some formats can be supported in Recipe, like 16-bit BCD, 16-bit signed, 16-bit unsigned, 32-bit BCD, 32-bit signed, 32-bit unsigned, 32-bit floating and string. If each member requires different formats, please set it one by one in form; ... ... @@ -251,7 +251,7 @@ 251 251 ))) 252 252 253 253 254 -** Description ofadcanced mode**248 +**description of Adcanced mode** 255 255 256 256 According to the recipe configuration information in Figure 2 above. The function address is HDW70, and each function configuration corresponds to the group number address, recipe element address and recipe file name address. The recipe information configured in figure 2 can be displayed in the table in figure 3 with the "Record Display" object. 257 257 ... ... @@ -886,14 +886,11 @@ 886 886 (For both username and password, it can not repetition) 887 887 ))) 888 888 889 -(% class="box infomessage" %) 890 -((( 891 891 **✎Note:** 892 892 893 893 * *1: If there is an admin user account, then the new user can no longer add one more admin, that is, one project can only have one administrator account. 894 894 * *1: When adding new user, the password could not be duplicated with other users. 895 895 * *2: When deleting user, it is forbidden to delete the admin user. 896 -))) 897 897 898 898 **User Permission Demo Download** 899 899 ... ... @@ -935,14 +935,11 @@ 935 935 936 936 User deletes default content or modifies default content, but he wants to give up modification back to original, just click "Reload text". 937 937 938 -(% class="box infomessage" %) 939 -((( 940 940 **✎Note:** 941 941 942 942 * If you do not want this prompt during the running of HMI, please uncheck "Show message". 943 943 * "Reload text" function would be invalid after clicking "save". 944 944 * These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&". 945 -))) 946 946 947 947 = **Cloud** = 948 948