... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Hunter
Content
... ... @@ -1,7 +1,7 @@
1 1  (% class="wikigeneratedid" id="H8BasicFunction" %)
2 2  This chapter provides information about basic functions and configuration in PIStudio.
3 3  
4 -= **{{id name="_Toc28532"/}}Alarm** =
4 += **Alarm** =
5 5  
6 6  == **Bit alarm** ==
7 7  
... ... @@ -18,7 +18,7 @@
18 18  1. **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
19 19  1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
20 20  
21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series after system upgrade are supported)
22 22  
23 23  **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
24 24  
... ... @@ -60,7 +60,7 @@
60 60  1. Other settings can be set according to the actual situation".
61 61  1. Click "OK" button to complete settings.
62 62  
63 -== **{{id name="_Toc5343"/}}{{id name="_Word_alarm"/}}Word Alarm** ==
63 +== **Word Alarm** ==
64 64  
65 65  Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated.
66 66  
... ... @@ -783,10 +783,12 @@
783 783  * "Reload text" function would be invalid after clicking "save".
784 784  * These 5 special characters are not supported in the header Multi language settings: ",", "|", "<", ">", "&".
785 785  
786 -= **Cloud (Only ig series)** =
786 += **Cloud** =
787 787  
788 788  **Introduction**
789 789  
790 +Cloud function is available for following models: the ig series and 8000/9000 series with -R after system upgrade
791 +
790 790  You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.)
791 791  
792 792  Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure.
... ... @@ -796,14 +796,24 @@
796 796  
797 797  **(1) Enable**
798 798  
799 -If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
801 +If the HMI supports the Cloud function, check it to enable the Cloud function, and it will collect the real-time data from HMI upload to the Cloud. The number of data collection is limited, and the specific parameters are as follows:
800 800  
801 -1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
802 -1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
803 -1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
803 +|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data
804 +|8000-R|300|200|100|1000
805 +|9000-R|300|200|100|1000
806 +|3000ig|100|20|50|500
807 +|8000ig|300|200|100|1000
804 804  
805 -**{{id name="_GoBack"/}}(2) Server Selection**
809 +For example:
806 806  
811 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
812 +
813 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
814 +
815 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
816 +
817 +**(2) Server Selection**
818 +
807 807   **Server**: China, ASEAN, and Europe.
808 808  
809 809   **Password**: