Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,9 @@ 1 1 (% class="wikigeneratedid" id="H8BasicFunction" %) 2 -This chapter provides information about basic functions and config uration in PIStudio.2 +This chapter provides information about basic functions and configiration in PIStudio. 3 3 4 -= **Alarm** = 4 += **{{id name="_Toc28532"/}}Alarm** = 5 5 6 -== **Bit alarm** ==6 +== **Bit Alarm** == 7 7 8 8 Click "Project"->"Bit alarm", it is displayed as the following figure. 9 9 ... ... @@ -18,7 +18,7 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud aand it is alarm data. (Only ig supported) 22 22 23 23 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 24 24 ... ... @@ -37,7 +37,7 @@ 37 37 38 38 **✎Note:** 39 39 40 -* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 40 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communnication port of the address in the configuration of the imported bit alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 41 41 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 42 42 43 43 **Operating Procedures of Adding One Alarm** ... ... @@ -64,7 +64,7 @@ 64 64 65 65 Word alarm is to monitor the word address of a device. If the data meets the set conditions, an alarm will be generated. 66 66 67 -Click "P roject"->"Word alarm", it is displayed as the following figure.67 +Click "Porject"->"Word alarm", it is displayed as the following figure. 68 68 69 69 (% style="text-align:center" %) 70 70 [[image:字报警 1.png||class="img-thumbnail"]] ... ... @@ -77,11 +77,11 @@ 77 77 78 78 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 79 79 80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 80 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud aand it is alarm data. (Only ig supported) 81 81 82 82 **✎Note:** 83 83 84 -* If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 84 +* If the "cloud" function is enabled and "upload to cloud" is checked, the communnication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally. 85 85 * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure. 86 86 87 87 **(6) Record alarm:** Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location. ... ... @@ -119,13 +119,13 @@ 119 119 1. Click "Project"-> "Word Alarm" as below shows. 120 120 121 121 (% style="text-align:center" %) 122 -[[image:8.Basic Function_html_1b59522c984cd7c2.png||height="144" width="492" class="img-thumbnail"]]122 +[[image:8.Basic Function_html_1b59522c984cd7c2.png||class="img-thumbnail" height="144" width="492"]] 123 123 124 124 (% start="2" %) 125 125 1. Click [Add] button to open [Word Alarm] setting window. 126 126 127 127 (% style="text-align:center" %) 128 -[[image:8.Basic Function_html_942107c81fc6901c.png||height="307" width="554" class="img-thumbnail"]]128 +[[image:8.Basic Function_html_942107c81fc6901c.png||class="img-thumbnail" height="307" width="554"]] 129 129 130 130 (% start="3" %) 131 131 1. Set Basic information of word alarm. ... ... @@ -150,7 +150,7 @@ 150 150 151 151 The maximum number of group in recipe is 1000, and the maximum number of member in each group is 1500. 152 152 153 -Recipe could store the data in USB flash disk and SD card and view the recipe data by ob ject "Recipe display". It has two mode: simple mode and advanced mode.153 +Recipe could store the data in USB flash disk and SD card and view the recipe data by obejct "Recipe display". It has two mode: simple mode and advanced mode. 154 154 155 155 1. **Simple: **Only support the data operation of one recipe file, including read and write. 156 156 1. **Advanced:** Support the data operation of multiple recipe files, including read, write, insert and index. View and select recipe file by object "File list". ... ... @@ -232,12 +232,12 @@ 232 232 1) Click "Project"->"Bit Alarm" as below shows. 233 233 234 234 (% style="text-align:center" %) 235 -[[image:8.Basic Function_html_a7d1546a3a9f752f.png||height="144" width="535" class="img-thumbnail"]]235 +[[image:8.Basic Function_html_a7d1546a3a9f752f.png||class="img-thumbnail" height="144" width="535"]] 236 236 237 237 2) Click "Add" button to open "Recipe" setting window. 238 238 239 239 (% style="text-align:center" %) 240 -[[image:8.Basic Function_html_8f04e01413981054.png||height="307" width="554" class="img-thumbnail"]]240 +[[image:8.Basic Function_html_8f04e01413981054.png||class="img-thumbnail" height="307" width="554"]] 241 241 242 242 3) Set basic settings for recipe. 243 243 ... ... @@ -273,9 +273,9 @@ 273 273 274 274 == **Recipe display** == 275 275 276 -Select the file type "Traditional recipe file" in o bject "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.276 +Select the file type "Traditional recipe file" in onject "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line. 277 277 278 -**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as foll owing shown:278 +**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as follwoing shown: 279 279 280 280 (% style="text-align:center" %) 281 281 [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]] ... ... @@ -366,7 +366,7 @@ 366 366 367 367 **(1) Basic settings** 368 368 369 -1. **Curve NO.: **It is for setting curve 369 +1. **Curve NO.: **It is for setting curvenumber, 370 370 1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes. 371 371 1. **Curve (1~~8):** It is for setting the number of curves. The default is 3. 372 372 1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves. ... ... @@ -373,7 +373,7 @@ 373 373 374 374 **(2) Sample Type** 375 375 376 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit.376 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit. 377 377 1. **Sample unit:** 100ms. 378 378 379 379 **(3) Quick Setting** ... ... @@ -384,7 +384,7 @@ 384 384 [[image:趋势图设置 3.png||class="img-thumbnail"]] 385 385 386 386 (% start="2" %) 387 -1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use contin uous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.387 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 388 388 389 389 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 390 390 ... ... @@ -408,7 +408,7 @@ 408 408 409 409 **(1) Basic settings** 410 410 411 -1. **Curve NO.: **It is for setting curve 411 +1. **Curve NO.: **It is for setting curvenumber, 412 412 1. **Curve Name:** It is for setting curve name. The length limitation is 31 bytes. 413 413 1. **Curve (1~~8):** It is for setting the number of curves. The default is 3. 414 414 1. **Dots of one curve: **It is for setting dots number of each curve. The default is 1000, but the maximum dots are 10,000 for all the curves. ... ... @@ -415,7 +415,7 @@ 415 415 416 416 **(2) Sample Type** 417 417 418 -1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to edit.418 +1. **Sample method:** There are two types, one is Cycle sample, the other is Trigger cycle sample. If you select Trigger cycle same mode, the trigger sample address is required to adit. 419 419 1. **Sample unit:** 100ms. 420 420 421 421 **(3) Quick Setting** ... ... @@ -423,10 +423,10 @@ 423 423 1. **Data format: **It is for setting all the curves, select the data format for all curves, and setting the reading addresses for curves. There are as follows. 424 424 425 425 (% style="text-align:center" %) 426 -[[image: image-20220616145435-1.png]]426 +[[image:http://docs.we-con.com.cn/wiki/pistudio/download/Helps/08.Basic%20Function/WebHome/%E8%B6%8B%E5%8A%BF%E5%9B%BE%E8%AE%BE%E7%BD%AE%203.png?rev=1.1||alt="趋势图设置 3.png" class="img-thumbnail"]] 427 427 428 428 (% start="2" %) 429 -1. **Sample address: **Fill in the start address that read the device data. If the sampl eaddress is consecutive, check "use continuous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3.429 +1. **Sample address: **Fill in the start address that read the device data. If the sampl address is consecutive, check "use continous address". For example, set HDW0 as start address, curve number is 3, then the HDW0 is for Curve 1, HDW1 is for Curve2, HDW2 is for Curve 3. 430 430 431 431 **(4) Curve Table:** The sample address you have set would display on it. Click the corresponding box to modify the content. 432 432 ... ... @@ -437,13 +437,13 @@ 437 437 1. Click "Project" -> "History XY Plot" to open the function selecting windows. 438 438 439 439 (% style="text-align:center" %) 440 -[[image:8.Basic Function_html_5da6ca44bd28acbe.png||height="144" width="533" class="img-thumbnail"]]440 +[[image:8.Basic Function_html_5da6ca44bd28acbe.png||class="img-thumbnail" height="144" width="533"]] 441 441 442 442 (% start="2" %) 443 443 1. Click "Add" button to open [History XY Plot] setting windows. 444 444 445 445 (% style="text-align:center" %) 446 -[[image:8.Basic Function_html_6345b50ea55168fa.png||height="307" width="554" class="img-thumbnail"]]446 +[[image:8.Basic Function_html_6345b50ea55168fa.png||class="img-thumbnail" height="307" width="554"]] 447 447 448 448 1. Setting the function of History XY Plot. 449 449 1. Click "OK" to save the setting. ... ... @@ -459,11 +459,11 @@ 459 459 The topology is shown in the following figure. 460 460 461 461 (% style="text-align:center" %) 462 -[[image:8.Basic Function_html_1b4bd09dafa7e049.png||height="332" width="554" class="img-thumbnail"]]462 +[[image:8.Basic Function_html_1b4bd09dafa7e049.png||class="img-thumbnail" height="332" width="554"]] 463 463 464 464 The data record stored in SD card is also organized according to the above figure. 465 465 466 -The sample time and save time is consistent in the same record group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address. 466 +The sample time and save time is consistent in the same recored group. There are multiple channels in the group, When the sampling time is up, every channel would collect data to PLC register according to its own address. 467 467 468 468 **Sampling interval: **The interval between two consecutive samples was recorded. 469 469 ... ... @@ -477,7 +477,7 @@ 477 477 **Settings** 478 478 479 479 (% style="text-align:center" %) 480 -[[image:数据记录设置 1.png||height="533" width="848" class="img-thumbnail"]]480 +[[image:数据记录设置 1.png||class="img-thumbnail" height="533" width="848"]] 481 481 482 482 **Operating Procedures** 483 483 ... ... @@ -501,7 +501,7 @@ 501 501 * If the total amount exceeds the range, an alarm will be given during project compilation. 502 502 503 503 (% style="text-align:center" %) 504 -[[image:数据记录设置 2.png||height="572" width="850" class="img-thumbnail"]]504 +[[image:数据记录设置 2.png||class="img-thumbnail" height="572" width="850"]] 505 505 506 506 **(1) Group name:** Set group name, and he name should be unique. 507 507 ... ... @@ -511,7 +511,7 @@ 511 511 1. **Trigger to record by sample cycle: **Data will be recorded in every same time, when trigger control bit set ON. 512 512 1. **Trigger to record once and reset: **Data will be recorded when trigger control bit set ON, and the bit will be reset automatically. 513 513 1. **Trigger to record once: **Data will be recorded when trigger control bit set ON, and the bit need to be reset manually. 514 -1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cycle for trigger sampling address is 1s. 514 +1. **Trigger address: **It is only valid when the trigger condition is selected. The monitoring cyclce for trigger sampling address is 1s. 515 515 516 516 **(3) Total channels (1~~100): **Set the numbers of channels. Click "apply" to view the channel lists on the right record channel. 517 517 ... ... @@ -527,8 +527,8 @@ 527 527 528 528 **(7) Quick Settings** 529 529 530 -1. **Start Channel:** It sets the continuous addresses 531 -1. **Data Format: **It sets 530 +1. **Start Channel:** It sets the continuous addressesfor channels. 531 +1. **Data Format: **It setsthe samedata format for channels. 532 532 1. **Number of Digits:** It sets the digits’ number for channels. 533 533 1. **Language Settings**: The text in HMI can be in 8 languages, user can set language in here. 534 534 ... ... @@ -570,7 +570,7 @@ 570 570 [[image:用户权限 1.png||class="img-thumbnail"]] 571 571 572 572 1. Click "User Permission" in "Data Tool" toolbar. 573 -1. Edit user name, click "User0" cell 573 +1. Edit user name, click "User0" cellunder "UserName", and then enter the user name, one project allows maximum 20 users. 574 574 1. Edit password, click "User0" cell under "PassWord", and then enter the user name. 575 575 1. Edit description, click "User0" cell under "Desc", and then enter, description is not necessary。 576 576 1. Check the groups for each user, there are 11 groups beside admin. ... ... @@ -597,7 +597,7 @@ 597 597 1. Enter [Log Message], it is for operation records, if it was empty, the operation for this object would be not be recorded; 598 598 1. Select the ~[[[Access Denied Setting>>path:#_Security]]] mode; 599 599 600 -**Log i nformation description**600 +**Log imformation description** 601 601 602 602 1. A combination of Chinese characters, numbers, and uppercase and lowercase letters can be entered, and the number does not exceed 63. 603 603 1. The format of insert variable:{variable address, data format}. e.g., {HDW100,UW2.1}. ... ... @@ -749,7 +749,7 @@ 749 749 [[image:消息提示 2.png||class="img-thumbnail"]] 750 750 751 751 (% style="text-align:center" %) 752 -[[image:8.Basic Function_html_5ce2091d6f7cd732.png||height="515" width="704" class="img-thumbnail"]]752 +[[image:8.Basic Function_html_5ce2091d6f7cd732.png||class="img-thumbnail" height="515" width="704"]] 753 753 754 754 **(1) Message** 755 755 ... ... @@ -762,7 +762,7 @@ 762 762 763 763 **For Example:** 764 764 765 -Trigger address is 011, during inserting 765 +Trigger address is 011, during insertinga USB flash disk into HMI, and 011 would be set ON, once HMI recognizes USB flash disk, and display message. 766 766 767 767 1. **Show message: **Check it to display message when HMI is running. It is checked by default. 768 768 1. **Show on web: **Check it to display message when remote access HMI screen, it is unchecked by default. ... ... @@ -781,7 +781,7 @@ 781 781 782 782 * If you do not want this prompt during the running of HMI, please uncheck "Show message". 783 783 * "Reload text" function would be invalid after clicking "save". 784 -* These 5 special characters are not supported in the header Multi 784 +* These 5 special characters are not supported in the header Multilanguage settings: ",", "|", "<", ">", "&". 785 785 786 786 = **Cloud (Only ig series)** = 787 787 ... ... @@ -792,7 +792,7 @@ 792 792 Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. 793 793 794 794 (% style="text-align:center" %) 795 -[[image:云配置1.png||height="494" width="750" class="img-thumbnail"]]795 +[[image:云配置1.png||class="img-thumbnail" height="494" width="750"]] 796 796 797 797 **(1) Enable** 798 798 ... ... @@ -824,3 +824,45 @@ 824 824 825 825 1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default. 826 826 1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags. 827 + 828 += **Cloud (Only ig series)** = 829 + 830 +**Introduction** 831 + 832 +You may configure the basic settings of Cloud functions, tags, and User MQTT according to your needs. (If the device supports the Cloud function, you can use the function and configure the tags after checking the box to enable it, or upload the data to the 3rd party server.) 833 + 834 +Click "Project"-"[[image:hh_B4H5OuNT87.png||height="29" width="30"]]Cloud" in the upper left corner of the software, as shown in the following figure. 835 + 836 +(% style="text-align:center" %) 837 +[[image:云配置1.png||class="img-thumbnail" height="494" width="750"]] 838 + 839 +**(1) Enable** 840 + 841 +If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows. 842 + 843 +1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100. 844 +1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.4AlarmRecord]] for details) 845 +1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#H8.3DataRecord]]) 846 + 847 +**{{id name="_GoBack"/}}(2) Server Selection** 848 + 849 + **Server**: China, ASEAN, and Europe. 850 + 851 + **Password**: 852 + 853 +1. If the HMI is not bound, this access password will be updated and downloaded into the HMI screen simultaneously. 854 +1. If the HMI is bound, this access password in the project cannot effectively change the binding password of the device, and it can only be changed through V-NET. 855 + 856 +**(3) Upload Selection**: 857 + 858 +To upload the data collected by HMI to the cloud or a to the third-party server, only one upload method can be selected. 859 + 860 +1. **to Cloud**: All the configured tags, data records, and alarm records would be pushed to V-NET. 861 +1. **to User MQTT**: All the configured tags, data records, and alarm records would be pushed to to the third-party server, and the relevant Lua function calls please refer to [[Cloud interface>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/10.Lua/#H10.19CloudInterface]]. 862 + 863 +After the "to User MQTT" is checked. The tags, data records, and alarms cannot be viewed on V-NET, but the device can be bound to V-NET and remote monitoring the device screen normally. 864 + 865 +**4) Low Data Mode setting** 866 + 867 +1. When you check the "low Data Mod" by default on new tags, the newly added tags will be enabled in Low Data Mode by default. 868 +1. The longer the refresh interval, the slower the data upload, and the more traffic data will be saved. This function is only used for the control of tags.
- image-20220616145435-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.6 KB - Content