Changes for page 06 Data Tool

Last modified by Jett on 2025/02/18 16:43

From version 8.1
edited by Hunter
on 2022/07/09 10:00
Change comment: There is no comment for this version
To version 10.1
edited by Hunter
on 2022/07/09 10:24
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -18,7 +18,7 @@
18 18  1. **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
19 19  1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
20 20  
21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series after system upgrade are supported)
22 22  
23 23  **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
24 24  
... ... @@ -798,14 +798,24 @@
798 798  
799 799  **(1) Enable**
800 800  
801 -If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
801 +If the HMI supports the Cloud function, check it to enable the Cloud function, and it will collect the real-time data from HMI upload to the Cloud. The number of data collection is limited, and the specific parameters are as follows:
802 802  
803 -1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
804 -1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
805 -1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
803 +|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data
804 +|8000-R|300|200|100|1000
805 +|9000-R|300|200|100|1000
806 +|3000ig|100|20|50|500
807 +|8000ig|300|200|100|1000
806 806  
807 -**{{id name="_GoBack"/}}(2) Server Selection**
809 +For example:
808 808  
811 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
812 +
813 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
814 +
815 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
816 +
817 +**(2) Server Selection**
818 +
809 809   **Server**: China, ASEAN, and Europe.
810 810  
811 811   **Password**: