Changes for page 06 Data Tool
Last modified by Jett on 2025/02/18 16:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,9 +3,9 @@ 3 3 4 4 = **Alarm** = 5 5 6 -== **Bit alarm** ==6 +== **Bit Alarm** == 7 7 8 -Click "Project"->"Bit alarm", it is displayed as the following figure.8 +Click "Project"->"Bit Alarm", it is displayed as the following figure. 9 9 10 10 (% style="text-align:center" %) 11 11 [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] ... ... @@ -18,8 +18,21 @@ 18 18 1. **Record bit alarm by default:** Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location. 19 19 1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file. 20 20 21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported) 22 22 23 +**✎Note:** 24 + 25 +(1) After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally. 26 + 27 +(2) The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table: 28 + 29 +(% style="margin-left:auto; margin-right:auto; width:358px" %) 30 +|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud 31 +|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200 32 +|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200 33 +|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20 34 +|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200 35 + 23 23 **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF. 24 24 25 25 **(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0. ... ... @@ -77,7 +77,7 @@ 77 77 78 78 **(4) Group No.: **Group number of word alarm. The name is unique and cannot be duplicated. 79 79 80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported) 93 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. ((Only ig series and 8000/9000 series with -R after system upgrade are supported)) 81 81 82 82 **✎Note:** 83 83 ... ... @@ -798,14 +798,24 @@ 798 798 799 799 **(1) Enable** 800 800 801 -If the HMI supports Cloud, select"enable" and"tocloud",then it willuploadthe real-time datasampledby theHMI to thecloud. The number of tagsis limited, the specific parameters are as follows.814 +If the HMI supports the Cloud function, check it to enable the Cloud function, and it will collect the real-time data from HMI upload to the Cloud. The number of data collection is limited, and the specific parameters are as follows: 802 802 803 -1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100. 804 -1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 805 -1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 816 +|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data 817 +|8000-R|300|200|100|1000 818 +|9000-R|300|200|100|1000 819 +|3000ig|100|20|50|500 820 +|8000ig|300|200|100|1000 806 806 807 - **{{id name="_GoBack"/}}(2) ServerSelection**822 +For example: 808 808 824 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100. 825 + 826 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details). 827 + 828 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]). 829 + 830 +**(2) Server Selection** 831 + 809 809 **Server**: China, ASEAN, and Europe. 810 810 811 811 **Password**: