... ... @@ -3,9 +3,9 @@
3 3  
4 4  = **Alarm** =
5 5  
6 -== **Bit alarm** ==
6 +== **Bit Alarm** ==
7 7  
8 -Click "Project"->"Bit alarm", it is displayed as the following figure.
8 +Click "Project"->"Bit Alarm", it is displayed as the following figure.
9 9  
10 10  (% style="text-align:center" %)
11 11  [[image:位报警 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]]
... ... @@ -18,8 +18,20 @@
18 18  1. **Record bit alarm by default:**  Whether to record the alarm history data of bit alarm, if checked, it will be saved in the designated storage location.
19 19  1. **Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
20 20  
21 -**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
21 +**(3) Upload to Cloud: **The data upload by "bit alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
22 22  
23 +**✎Note:**
24 +
25 +* After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Bit Alarm record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
26 +* The number of Alarm records upload to Cloud shall not exceed the limit value, or the sum of the imported alarm records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
27 +
28 +(% style="margin-left:auto; margin-right:auto; width:358px" %)
29 +|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
30 +|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
31 +|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
32 +|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
33 +|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
34 +
23 23  **(4) Alarm Condition:** It sets alarm trigger condition, there are two types: alarm when ON and alarm when OFF.
24 24  
25 25  **(5) Alert: **It is used to mark whether the alarm has occurred. if an alarm occurs, the address of "control bit" will be written to 1. If "clear alert when alarm OFF" is checked, the address of "control bit" will be written to 0.
... ... @@ -77,7 +77,7 @@
77 77  
78 78  **(4)  Group No.: **Group number of word alarm. The name is unique and cannot be duplicated.
79 79  
80 -**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig supported)
92 +**(5) Upload to Cloud: **The data upload by "word alarm" is stored in the Cloud and it is alarm data. (Only ig series and 8000/9000 series with -R after system upgrade are supported)
81 81  
82 82  **✎Note:**
83 83  
... ... @@ -84,6 +84,13 @@
84 84  * If the "cloud" function is enabled and "upload to cloud" is checked, the communication port of the address in the configuration of the imported word alarm record must be the same as that of the current project; otherwise, it cannot be used normally.
85 85  * The number of alarm configuration points reported to the cloud cannot exceed 20, or the sum of imported alarm records and the current alarm records cannot exceed 20. If it exceeds, please reconfigure.
86 86  
99 +(% style="margin-left:auto; margin-right:auto; width:358px" %)
100 +|=(% style="width: 79px;" %)Series|=(% style="width: 276px;" %)Number of Alarm upload to Cloud
101 +|(% style="width:79px" %)8000-R|(% style="text-align:center; width:276px" %)200
102 +|(% style="width:79px" %)9000-R|(% style="text-align:center; width:276px" %)200
103 +|(% style="width:79px" %)3000ig|(% style="text-align:center; width:276px" %)20
104 +|(% style="width:79px" %)8000ig|(% style="text-align:center; width:276px" %)200
105 +
87 87  **(6) Record alarm:**  Whether to record the alarm history data of word alarm, if checked, it will be saved in the designated storage location.
88 88  
89 89  **(7) Not save alarm OFF:** If checked, after the alarm is dismissed, the corresponding alarm records will be deleted from the log file.
... ... @@ -275,7 +275,7 @@
275 275  
276 276  Select the file type "Traditional recipe file" in object "Recipe Display", and it is recommended to fill in the traditional recipe group number HSW1612 to the address of select line.
277 277  
278 -**✎Note**: The Recipe Display can display up to 50 groups of 100 elements, which can be to display out of range by enabled "Address Control", as following shown:
297 +**✎Note**: The Recipe Display can display up to 50 groups of 100 elements by default, which can be to display out of range by enabled "Address Control". After the "Address Control" is enabled, the display group number can be reached to 100. If want to display more than 100, please adjust the "Start Group" from "Address Control" to index the display group, as following shown:
279 279  
280 280  (% style="text-align:center" %)
281 281  [[image:8-4TraditionalRecipeDisplayConfigScreen.png||class="img-thumbnail"]]
... ... @@ -471,8 +471,24 @@
471 471  
472 472  For the file storage of data, see the file size configuration during data record configuration.
473 473  
474 -✎**Note: **The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.
493 +✎**Note: **
475 475  
495 +1) After enable the Cloud and check the box of Upload to Cloud, the communication port settings of the address in the imported Data record configuration must be the same as the communication port settings of the current project, otherwise it cannot be used normally.
496 +
497 +2) The number of Data records upload to Cloud shall not exceed the limit value, or the sum of the imported Data records and the number of existing alarm records shall not exceed the limit value. the specific limitation as following table:
498 +
499 +(% style="margin-left:auto; margin-right:auto; width:513px" %)
500 +|=(% style="width: 70px;" %)Series|=(% style="width: 442px;" %)Number of Data Record upload to Cloud
501 +|(% style="width:70px" %)8000-R|(% style="text-align:center; width:442px" %)100
502 +|(% style="width:70px" %)9000-R|(% style="text-align:center; width:442px" %)100
503 +|(% style="width:70px" %)3000ig|(% style="text-align:center; width:442px" %)50
504 +|(% style="width:70px" %)8000ig|(% style="text-align:center; width:442px" %)100
505 +
506 +3) The record group name can only be composed of Chinese characters, (0~~9), (a~~z), (A~~Z), ('_'), ('') and other non-English characters.
507 +
508 +4) Channel name cannot incloud following symbols: :" , ", " | ", " < ", " > ", " & ".
509 +
510 +
476 476  (% class="wikigeneratedid" id="HSettings" %)
477 477  **Settings**
478 478  
... ... @@ -798,14 +798,24 @@
798 798  
799 799  **(1) Enable**
800 800  
801 -If the HMI supports Cloud, select "enable" and "to cloud", then it will upload the real-time data sampled by the HMI to the cloud. The number of tags is limited, the specific parameters are as follows.
836 +If the HMI supports the Cloud function, check it to enable the Cloud function, and it will collect the real-time data from HMI upload to the Cloud. The number of data collection is limited, and the specific parameters are as follows:
802 802  
803 -1. In Cloud, the monitoring tags upload to the cloud in real time is limited to 100.
804 -1. The total number of data upload to the Cloud for the Alarm records of word alarms and bit alarms is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
805 -1. The total number of data upload to the Cloud for Data record is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
838 +|=Series|=Monitoring Tags|=Alarm Record|=Data Record|=OpenCloud Data
839 +|8000-R|300|200|100|1000
840 +|9000-R|300|200|100|1000
841 +|3000ig|100|20|50|500
842 +|8000ig|300|200|100|1000
806 806  
807 -**{{id name="_GoBack"/}}(2) Server Selection**
844 +For example:
808 808  
846 +~1. In 3000ig's Cloud, the monitoring tags upload to the Cloud in real time is limited to 100.
847 +
848 +2. For 3000ig's Alarm, the Alarm records of word alarms and bit alarms upload to Cloud is limited to 20. (See [["Alarm">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HAlarm]] for details).
849 +
850 +3. For 3000ig's Data record, the Data records upload to Cloud is limited to 50. (For details, please refer to [["Data Record">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/08.Basic%20Function/#HDataRecord]]).
851 +
852 +**(2) Server Selection**
853 +