Changes for page 10 Advanced Function

Last modified by Jett on 2025/04/15 09:59

From version 15.1
edited by Mora Zhou
on 2023/11/21 14:45
Change comment: There is no comment for this version
To version 2.2
edited by Leo Wei
on 2022/07/29 15:02
Change comment: Update document after refactoring.

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.admin
Content
... ... @@ -6,17 +6,17 @@
6 6  1. Audio playing could play audio on HMI. You need to configure the relevant information, triggered by the condition, broadcast the set the mp3 audio file. The audio file can only be stored in the flash mp3 file.
7 7  1. Only the 9000 Series HMIs with audio modules can use this feature, and an external 3.5mm headphone head is required.
8 8  
9 -== Configuration ==
9 +== **Configuration** ==
10 10  
11 11  In PIStudio software, the setting procedue is as follow.
12 12  
13 13  (% style="text-align:center" %)
14 -[[image:音频 1.png||height="655" width="528" class="img-thumbnail"]]
14 +[[image:音频 1.png||class="img-thumbnail" height="655" width="528"]]
15 15  
16 -**Click "Set" to open "Audio settings" window.**
16 +**(1) Click "Set" to open "Audio settings" window.**
17 17  
18 18  (% style="text-align:center" %)
19 -[[image:11.Advanced Function_html_949272a66c003cd.png||height="402" width="588" class="img-thumbnail"]]
19 +[[image:11.Advanced Function_html_949272a66c003cd.png||class="img-thumbnail" height="402" width="588"]]
20 20  
21 21  * Audio list: Display the audio files you added. Double click the audio to configure it.
22 22  * Add: Add a new audio file.
... ... @@ -23,35 +23,41 @@
23 23  * Delete: Delete selected audio file.
24 24  * Audio set: Set the configurations of the audio, contolled by address.
25 25  
26 -**Trigger configuration for audio files**
26 +**(2) Trigger configuration for audio files**
27 27  
28 28  (% style="text-align:center" %)
29 29  [[image:音频 2.png||class="img-thumbnail"]]
30 30  
31 -* **Audio files**
32 -** MP3 file supported only.
33 -** The audio filesize should be less than 30MB.
34 -** The suffix .mp3 is necessary. The length of name should be less than 20 (including .mp3).
35 -** Audio file needs to be saved into the folder named mp3 in HMI flash, if not, it would not play. User could use the ~[[[CopyFile>>path:#_CopyFile]]] script function to import audio files into the HMI flash.
36 -* **Trigger mode settings: **There are 3 kinds trigger mode to choose. They coulf be valid at the same time.
37 -** **Play according to time interval: **Set the interval time. For example ,set 3 minutes, then it will play for each 3 minutes' interval.
38 -** **Trigger to play: **There are three bit trigger conditions: Rising edge, Falling edge and Bit change. You could trigger one condition to play the audio file.
39 -** **Play according to time: **Play the audio when the time is up.
40 -* **Play settings.** Set the play times and the cycle interval when it is triggered.
31 +**1) Audio files**
41 41  
42 -**Audio file playback setting**
33 +* MP3 file supported only.
34 +* The audio filesize should be less than 30MB.
35 +* The suffix .mp3 is necessary. The length of name should be less than 20 (including .mp3).
36 +* Audio file needs to be saved into the folder named mp3 in HMI flash, if not, it would not play. User could use the ~[[[CopyFile>>path:#_CopyFile]]] script function to import audio files into the HMI flash.
43 43  
38 +**2) Trigger mode settings**
39 +
40 +There are 3 kinds trigger mode to choose. They coulf be valid at the same time.
41 +
42 +* **Play according to time interval: **Set the interval time. For example ,set 3 minutes, then it will play for each 3 minutes' interval.
43 +* **Trigger to play: **There are three bit trigger conditions: Rising edge, Falling edge and Bit change. You could trigger one condition to play the audio file.
44 +* **Play according to time: **Play the audio when the time is up.
45 +
46 +**3) Play settings.** Set the play times and the cycle interval when it is triggered.
47 +
48 +**(3) Audio file playback setting**
49 +
44 44  This function is to control the playback of audio file in the list by address. (It should be used with file list.)
45 45  
46 46  (% style="text-align:center" %)
47 -[[image:音频 3.png||height="429" width="620" class="img-thumbnail"]]
53 +[[image:音频 3.png||class="img-thumbnail" height="429" width="620"]]
48 48  
49 -== Control address ==
55 +== **Control address** ==
50 50  
51 51  The table below describes each bit address function (including play, pause, etc). If the audio control address is HDW120, then specific function details are as shown in the table below.
52 52  
53 53  (% class="table-bordered" %)
54 -|=(% scope="row" %)**Function**|=(% style="width: 177px;" %)**Address**|=(% style="width: 647px;" %)**Description**
60 +|=**Function**|=(% style="width: 177px;" %)**Address**|=(% style="width: 647px;" %)**Description**
55 55  |(% rowspan="7" %)Play Control|(% style="width:177px" %)HDX120.0 (0(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Play control bit: Play the audio file when this bit address is triggered
56 56  |(% style="width:177px" %)HDX120.1 (1(% style="font-size:10.5px" %)st(%%) bit)|(% style="width:647px" %)Pause control bit: Pause playback when this bit address is triggered, or resume playback after pause
57 57  |(% style="width:177px" %)HDX120.2 (2(% style="font-size:10.5px" %)nd(%%) bit)|(% style="width:647px" %)Stop control bit: Stop the play when this bit address is triggered
... ... @@ -64,13 +64,13 @@
64 64  |(% style="width:177px" %)HDX120.9 (9(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Order: Play audio file orderly and stop as soon as the tas finished
65 65  |(% style="width:177px" %)HDX120.10 (10(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Repeat in order: Repeat to play the audio file of the list
66 66  
67 -== State address ==
73 +== **State address** ==
68 68  
69 69  The audio play status address occupies a continuous 35 word addresses. If audio play status address is set as HDW200, the specific function allocation details are shown as below table
70 70  
71 71  (% class="table-bordered" %)
72 -|=(% scope="row" style="width: 183px;" %)**Address**|=(% style="width: 314px;" %)**Function**|=(% style="width: 592px;" %)**Description**
73 -|=(% style="width: 183px;" %)HDW200|(% style="width:314px" %)Playback status storage address|(% style="width:592px" %)(((
78 +|=(% style="width: 183px;" %)**Address**|=(% style="width: 314px;" %)**Function**|=(% style="width: 592px;" %)**Description**
79 +|(% style="width:183px" %)HDW200|(% style="width:314px" %)Playback status storage address|(% style="width:592px" %)(((
74 74  ~=0 : stop play
75 75  
76 76  ~=1 : playing
... ... @@ -77,16 +77,13 @@
77 77  
78 78  ~=2 : pause play
79 79  )))
80 -|=(% style="width: 183px;" %)HDW201|(% style="width:314px" %)Volume value storage address|(% style="width:592px" %)Range from 0 to 100(default value is 100, and it is not adjustable so fars
81 -|=(% style="width: 183px;" %)HDW202~~HDW234|(% style="width:314px" %)Audio file name|(% style="width:592px" %)Displays the file name of the audio currently playing
86 +|(% style="width:183px" %)HDW201|(% style="width:314px" %)Volume value storage address|(% style="width:592px" %)Range from 0 to 100(default value is 100, and it is not adjustable so fars
87 +|(% style="width:183px" %)HDW202~~HDW234|(% style="width:314px" %)Audio file name|(% style="width:592px" %)Displays the file name of the audio currently playing
82 82  
83 -(% class="box infomessage" %)
84 -(((
85 85  ✎**Note:**
86 86  
87 87  * The audio file needs to be stored in the flash of PI9000 series HMI.
88 88  * Only PI9000 series HMI with audio module could support this function, and an external 3.5mm headphone is required.
89 -)))
90 90  
91 91  = **Video** =
92 92  
... ... @@ -93,50 +93,49 @@
93 93  **Introduction**
94 94  
95 95  1. Configure related information and play video files through conditional trigger.
96 -1. Only HMI 9000 and 8150ig series support this function.
99 +1. Only HMI  9000 series support this function.
97 97  1. Video playing could play video on HMI project screen.
98 98  1. It requires "Customized Object" and "File List" objects.
99 99  1. Currently, the video format support by Wecon HMI are including ASF, AVI, MKV, MP4, RM, and FLV.
100 -1. Olny supports playback of 360P and 480P resolution video.
101 101  
102 -== Configuration ==
104 +== **Configuration** ==
103 103  
104 -**Custom object configuration**
106 +**(1) Custom object configuration**
105 105  
106 106  (% style="text-align:center" %)
107 -[[image:视频功能部件配置.png]]
109 +[[image:11.Advanced Function_html_4939953650efc334.png||class="img-thumbnail" height="499" width="415"]]
108 108  
109 -**Basic**
111 +**1) Basic**
110 110  
111 111  The function address doesn't have to be configured. DLL file name needs to be "Custom_MoviePlayer".
112 112  
113 -**Custom Address**
115 +**2) Custom Address**
114 114  
115 115  * ID1 is the address for storing the video file name (including the suffix). It could not be empty and the length is 32 words.
116 -* ID2 is the address for video control, and occupies 1 word. It could not be empty. Please refer to[[ "Video control address">>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HControladdress-1]].
118 +* ID2 is the address for video control, and occupies 1 word. It could not be empty. Please refer to[[ "Video control address">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/11.Advanced%20Function/#HControladdress-1]].
117 117  * ID3 is the address of video status, and occupies 1 word. It could not be empty. 0 indicate stop, and 1 indicates play.
118 -* ID4 is the address for stroring the volume of video file, and occupies 1 word. 8150ig can not adjust the volume, only 9000 series can be set.
119 -* ID5 is the address for the video file path, and occupies 1 word. It could not be empty. Please refer to [["Video file path">>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HFilepath]].
120 +* ID4 is the address for stroring the valume of video file, and occupies 1 word.
121 +* ID5 is the address for the video file path, and occupies 1 word. It could not be empty. Please refer to [["Video file path">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/11.Advanced%20Function/#HFilepath]].
120 120  
121 -== Control address ==
123 +== **Control address** ==
122 122  
123 123  (% class="table-bordered" %)
124 124  |=(% style="width: 151px;" %)**Function**|=(% colspan="2" style="width: 200px;" %)**Address**|=(% style="width: 599px;" %)**Description**
125 -|(% rowspan="7" style="width:151px" %)Play Control|(% style="width:92px" %)0(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.0|(% style="width:599px" %)(((
126 -Bit for playing control:This address save the name of the video file to be played.
127 +|(% rowspan="7" style="width:151px" %)Play Control|(% style="width:92px" %)0(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX102.0|(% style="width:599px" %)(((
128 +Bit for playing control: Play the video file when this bit address is triggered
127 127  )))
128 -|(% style="width:92px" %)1(% style="font-size:10.5px" %)st(%%) bit|(% style="width:107px" %)HDX100.1|(% style="width:599px" %)Bit for pause control:Pause playing when this bit address is triggered, or resume playing after pause
129 -|(% style="width:92px" %)2(% style="font-size:10.5px" %)nd(%%) bit|(% style="width:107px" %)HDX100.2|(% style="width:599px" %)Bit for full screen control: Maximize the video when this bit address is triggered
130 -|(% style="width:92px" %)3(% style="font-size:10.5px" %)rd(%%) bit|(% style="width:107px" %)HDX100.3|(% style="width:599px" %)Last video: Play the last video when this bit address is triggered.
131 -|(% style="width:92px" %)4(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.4|(% style="width:599px" %)Next video: Play the next video when this bit address is triggered.
132 -|(% style="width:92px" %)5(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.5|(% style="width:599px" %)Volume increase: Increased by 10 (only be supported 9000 series)
133 -|(% style="width:92px" %)6(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.6|(% style="width:599px" %)Volume decrease: Decreased by 10 (only be supported 9000 series)
134 -|(% rowspan="4" style="width:151px" %)Mode Selection|(% style="width:92px" %)7(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.7|(% style="width:599px" %)Once: Only play current video file once
135 -|(% style="width:92px" %)8(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.8|(% style="width:599px" %)Single cycle: Repeat to play current video file
136 -|(% style="width:92px" %)9(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.9|(% style="width:599px" %)Order: Play video file of the list and stop after done
137 -|(% style="width:92px" %)10(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.10|(% style="width:599px" %)Repeat in order: Repeat to play the video file of the list
130 +|(% style="width:92px" %)1(% style="font-size:10.5px" %)st(%%) bit|(% style="width:107px" %)HDX102.1|(% style="width:599px" %)Bit for pause control:Pause playing when this bit address is triggered, or resume playing after pause
131 +|(% style="width:92px" %)2(% style="font-size:10.5px" %)nd(%%) bit|(% style="width:107px" %)HDX102.2|(% style="width:599px" %)Bit for full screen control: Maximize the video when this bit address is triggered
132 +|(% style="width:92px" %)3(% style="font-size:10.5px" %)rd(%%) bit|(% style="width:107px" %)HDX102.3|(% style="width:599px" %)Last video: Play the last video when this bit address is triggered.
133 +|(% style="width:92px" %)4(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX102.4|(% style="width:599px" %)Next video: Play the next video when this bit address is triggered.
134 +|(% style="width:92px" %)5(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX102.5|(% style="width:599px" %)Volume increase: Increased by 10
135 +|(% style="width:92px" %)6(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX102.6|(% style="width:599px" %)Volume decrease: Decreased by 10
136 +|(% rowspan="4" style="width:151px" %)Mode Selection|(% style="width:92px" %)7(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX102.7|(% style="width:599px" %)Once: Only play current video file once
137 +|(% style="width:92px" %)8(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX102.8|(% style="width:599px" %)Single cycle: Repeat to play current video file
138 +|(% style="width:92px" %)9(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX102.9|(% style="width:599px" %)Order: Play video file of the list and stop after done
139 +|(% style="width:92px" %)10(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX102.10|(% style="width:599px" %)Repeat in order: Repeat to play the video file of the list
138 138  
139 -== (% style="color:inherit; font-family:inherit; font-size:23px" %)File path(%%) ==
141 +== (% style="color:inherit; font-family:inherit; font-size:23px" %)**File path**(%%) ==
140 140  
141 141  (% class="table-bordered" %)
142 142  |=**Value**|=**Video File Path**|=**Description**
... ... @@ -144,12 +144,12 @@
144 144  |1|SD card|Please create a folder named mp4 in the SD card directory to store the video files to be played
145 145  |2|HMI flash|Copy the video files to the mp4 folder in the directory of flash
146 146  
147 -== Case ==
149 +== **Case** ==
148 148  
149 -Operating Procedures of File List Object Settings
151 +**Operating Procedures of File List Object Settings**
150 150  
151 151  (% style="text-align:center" %)
152 -[[image:file setting.png]]
154 +[[image:11.Advanced Function_html_21e02c4465831a9e.png||class="img-thumbnail" height="560" width="600"]]
153 153  
154 154  Configure the customized object as the above picture
155 155  
... ... @@ -156,32 +156,35 @@
156 156  Configure the file list object as below:
157 157  
158 158  1. Select the directory as the MP4 folder in USB flash disk. Set the file name address as HDW150
161 +1. Create a folder named MP4 in the SD card directory to store the video files to be played.
159 159  1. Add the video controlling address, refer to the above video controlling address table.
160 160  1. Compile the project and download it to HMI, trigger the bit address to play the video from the list.
161 161  
162 -== Demo ==
163 -
164 -**PI8150ig Video Display: **[[Download link>>https://docs.we-con.com.cn/bin/view/PIStudio/2%20Demo/Applications/#H7PI8150igVideoDisplay]]
165 -
166 166  = **Email** =
167 167  
167 +**Introduction**
168 +
168 168  Wecon HMI can send email with information from fields to the specified email address as soon as the conditions is triggered, but email sending is based on the network.
169 169  
170 -== Email setting ==
171 +== **Email setting** ==
171 171  
172 -In "PIStudio" software, click "Project" "E-mail" to open email function setting screen.
173 +In "PIStudio" software, click "Project"-> "E-mail" to open email function setting screen.
173 173  
174 174  (% style="text-align:center" %)
175 -[[image:邮件 1.png||height="780" width="597" class="img-thumbnail"]]
176 +[[image:邮件 1.png||class="img-thumbnail" height="780" width="597"]]
176 176  
177 -**SMTP Settings**
178 +(**1) SMTP Settings**
178 178  
179 -* **Sender Name: **Fill the sender's name, which is composed of Chinese characters, letters (case sensitive) and numbers. But it can not contain the following special English symbols:  ',', ';', '"', '<'. Maximum character length 32 is allowed.
180 -* **Password:** Fill in the password or authorization code of the mailbox. If the server needs to set the authorization code, the authorization code needs to be used. If the authorization code is not used, the password is used. Please refer to the SMTP service in the mailbox for the authorization code information. It cases sensitive, maximum character length 32 allowed in password.
181 -* **Confirm Password: **Confirm the password or authorization code of the mailbox.
182 -* **Email Address: **Fill in the sender's email address, case sensitive, maximum character length 32 allowed in it.Such as [[support@we-con.com.cn>>path:mailto:support@we-con.com.cn]].
183 -* **SMTP Server: **Please refer to the mailbox account settings. If you enter a common mailbox, the corresponding server address will be automatically written. such as smtp.exmail.qq.com.
180 +**1) Sender Name: **Fill the sender's name, which is composed of Chinese characters, letters (case sensitive) and numbers. But it can not contain the following special English symbols:  ',', ';', '"', '<'. Maximum character length 32 is allowed.
184 184  
182 +**2) Password:** Fill in the password or authorization code of the mailbox. If the server needs to set the authorization code, the authorization code needs to be used. If the authorization code is not used, the password is used. Please refer to the SMTP service in the mailbox for the authorization code information. It cases sensitive, maximum character length 32 allowed in password.
183 +
184 +**3) Confirm Password: **Confirm the password or authorization code of the mailbox.
185 +
186 +**4) Email Address: **Fill in the sender's email address, case sensitive, maximum character length 32 allowed in it.Such as [[support@we-con.com.cn>>path:mailto:support@we-con.com.cn]].
187 +
188 +**5) SMTP Server: **Please refer to the mailbox account settings. If you enter a common mailbox, the corresponding server address will be automatically written. such as smtp.exmail.qq.com.
189 +
185 185  (% class="table-bordered" %)
186 186  |=Email|=Email server|=Port number
187 187  |163 email|smtp.163.com|465
... ... @@ -192,22 +192,29 @@
192 192  |Yahoo email|smtp.mail.yahoo.com.cn|465
193 193  |Google email|smtp.gmail.com|465
194 194  
195 -**✎Note:** Gmail also needs to enable the [allow unsafe apps] option in the account, otherwise the mail will not be sent normally.
200 +**✎Note:**
196 196  
202 +Gmail also needs to enable the [allow unsafe apps] option in the account, otherwise the mail will not be sent normally.
203 +
204 +**6) Encryption Type: **SSL is a security protocol that provides security and data integrity for network communications. It encrypts network connections at the transport layer; TLS (STARTTLS) upgrades connections to SSL instead of using a separate encrypted communication port.
205 +
206 +**7) The Port Number: **Enter corresponding port number according to the SMTP serve addrress entered. You could only enter interger between 1 and 65535. Do not enter more than 6 digits in length. Common port numbers are port 25, 465 and 587.
207 +
197 197  (% style="list-style-type:disc" %)
198 -* **Encryption Type: **SSL is a security protocol that provides security and data integrity for network communications. It encrypts network connections at the transport layer; TLS (STARTTLS) upgrades connections to SSL instead of using a separate encrypted communication port.
199 -* **The Port Number: **Enter corresponding port number according to the SMTP serve addrress entered. You could only enter interger between 1 and 65535. Do not enter more than 6 digits in length. Common port numbers are port 25, 465 and 587.
200 -** Port 25: It does not protect the original data when transmitting data. The data can be seen. Generally, port 25 must be selected as no encryption or TLS(STARTTLS) encryption mode to send data correctly.
201 -** Port 465: It protect the original data when transmitting data. The data can not be seen. Generally, port 465 must be selected as SSL encryption mode to send data correctly.
202 -** Port 587: The original data is protected only after the TLS(STARTTLS) command is executed. Generally, port 587 must be selected as TLS(STARTTLS) encryption mode to send data correctly.
209 +* Port 25: It does not protect the original data when transmitting data. The data can be seen. Generally, port 25 must be selected as no encryption or TLS(STARTTLS) encryption mode to send data correctly.
210 +* Port 465: It protect the original data when transmitting data. The data can not be seen. Generally, port 465 must be selected as SSL encryption mode to send data correctly.
211 +* Port 587: The original data is protected only after the TLS(STARTTLS) command is executed. Generally, port 587 must be selected as TLS(STARTTLS) encryption mode to send data correctly.
203 203  
204 204  **✎Note: **Port 25 is open to SMTP servers, mainly for sending mail. But the port has vulnerability. Hackers often use port 25 to find SMTP servers to forward spam.
205 205  
206 -* **Error Message**
207 -** Set the error message receiving address, you could use the information to get the reasons of errors.
208 -** The error types in the mail function are divided into two types: custom rule error and server's error.
209 -** Custom rule errors are as follows.
215 +**8) Error Message**
210 210  
217 +Set the error message receiving address, you could use the information to get the reasons of errors.
218 +
219 +The error types in the mail function are divided into two types: custom rule error and server's error.
220 +
221 +Custom rule errors are as follows.
222 +
211 211  (% class="table-bordered" %)
212 212  |**Message**
213 213  |Email settings are incorrect
... ... @@ -248,7 +248,7 @@
248 248  |could not connect: Connection refused
249 249  |smtp-server: 550 User not found: aaa.163.com
250 250  
251 -* **Manual Trigger**
263 +**9) Manual Trigger**
252 252  
253 253  It is for modifying the email sending settings when HMI is running. According to the set manual trigger address, the address is offset backward to get the address of the corresponding function (a total of 201 words). Take HDW100 as an example.
254 254  
... ... @@ -255,20 +255,18 @@
255 255  (% class="table-bordered" %)
256 256  |(% style="width:201px" %)**Address**|(% style="width:586px" %)**Description**
257 257  |(% style="width:201px" %)HDX100.0|(% style="width:586px" %)Sending trigger
258 -|(% style="width:201px" %)HDX101.0~~101.15|(% style="width:586px" %)It is used for triggering recipient groups, for example, HDW101.0 set ON, and the address in group 1 will be in recipient list.
259 -|(% style="width:201px" %)HDX103.0~~103.15|(% style="width:586px" %)It is used for triggering recipient groups, for example, HDW103.0 set ON, and the address in group 1 will be in CC list.
260 -|(% style="width:201px" %)HDX105.0~~105.15|(% style="width:586px" %)It is used for triggering recipient groups, for example, HDW105.0 set ON, and the address in group 1 will be in BCC list (Secret delivery).
261 -|(% style="width:201px" %)HDW107~~171|(% style="width:586px" %)The subject length is limited to 64 words. (If it exceeds, it will intercept 64 words of content); The length of 65 words only use 64 actually, the 65th word address is reserved;
262 -|(% style="width:201px" %)HDW172~~300|(% style="width:586px" %)The content length is limited to 128 words. (If it exceeds, it will intercept 128 words of content)
263 -|(% style="width:201px" %)HDX301.0|(% style="width:586px" %)Whether to send an alarm record file as attachment
264 -(HMI V1.0 filename: AlarmDataFile.db)
265 -(HMI V2.0 filename: AlarmDataFile_0.db)
270 +|(% style="width:201px" %)HDX101.0 to HDX101.15|(% style="width:586px" %)It is used for triggering recipient groups, for example, HDW101.0 set ON, and the address in group 1 will be in recipient list.
271 +|(% style="width:201px" %)HDX103.0 to HDX103.15|(% style="width:586px" %)It is used for triggering recipient groups, for example, HDW103.0 set ON, and the address in group 1 will be in CC list.
272 +|(% style="width:201px" %)HDX105.0 to HDX105.15|(% style="width:586px" %)It is used for triggering recipient groups, for example, HDW105.0 set ON, and the address in group 1 will be in BCC list (Secret delivery).
273 +|(% style="width:201px" %)HDW107 to HDW171|(% style="width:586px" %)The subject length is limited to 64 words. (If it exceeds, it will intercept 64 words of content)
274 +|(% style="width:201px" %)HDW172 to HDW300|(% style="width:586px" %)The content length is limited to 128 words. (If it exceeds, it will intercept 128 words of content)
275 +|(% style="width:201px" %)HDX301.0|(% style="width:586px" %)Whether to send an alarm record attachment (a file named AlarmDataFile.db)
266 266  
267 267  1. Emails that sent manually are not queued. Emails trigger by bit change, rising edge, falling edge and timing need to be sent in the sequence of triggering. The maximum value is 100, and those who are added after it is exceeded will be discarded. If an email is sending, it would send immediately after the current email is sent. If there is no email sending, it would send immediately.
268 268  1. If the trigger condition sent manually is the rising edge trigger, before the mail is sent, no new mail will be sent even if it is triggered again. No matter the email is sent successfully or not, the corresponding trigger would be OFF.
269 269  1. Emails that sent manually would only be sent once no matter the sending error is custom error, network or other errors.
270 270  
271 -== Email sending settings ==
281 +== **Email sending settings** ==
272 272  
273 273  (% style="text-align:center" %)
274 274  [[image:邮件 2.png||class="img-thumbnail"]]
... ... @@ -278,28 +278,38 @@
278 278  1. **Delete. **You could select an email to delete or click the "ID" column to delete in batch.
279 279  
280 280  (% style="text-align:center" %)
281 -[[image:邮件 3.png||height="578" width="744" class="img-thumbnail"]]
291 +[[image:邮件 3.png||class="img-thumbnail" height="578" width="744"]]
282 282  
283 -**Email sending configuration.**
293 +**(1) Email sending configuration.**
284 284  
285 -* **Theme. **The value cannot be empty and case sensitive. The total length  cannot exceed 256 characters.
286 -* **Content of email. **The contents are divided into three combinations: text, alarm and variable. The list can contain only 32 items at most, and the total length of the preview cannot exceed 1024 items.
287 -** **Text. **You could directly edit the text of language 1 to language 3. If you need to set multiple languages, click "edit all text" to set. You may also select "Text library". The content is case sensitive, and the total length of English/Chinese characters/numbers/symbols does not exceed 253.
288 -** **Alarm. **You could select "bit alarm" or "word alarm" from the list. The content is from alarm text. if the alarm changes, the content changes with it. The content is case sensitive, and the total length of English/Chinese characters/numbers/symbols does not exceed 253.
289 -** **Variable. **Set the corresponding variable address. Read value or strings according to the specified format, and the read information will be displayed in the corresponding position in the mail content.
290 -* **Preview. **Combine the content of current edited email and diaplay it for you to modify the content conviniently. The preview length cannot exceed 1024.
291 -* **Sending method. **It is divided into timed send interval and bit address trigger tranmission. The two methods cannot be used at the same time.
292 -** timed send interval. After booting, the current system time is used to start calculating, and each time the time  is up, the information will be sent to the set recipient in the form of an email, and the minimum time should be set to 5 minutes. **Note: **The first boot is not sent.
293 -** Bit address trigger tranmission. When the set trigger address meets the trigger conditon, the information will be sent to the set recipient in the form of an email. If the content select alarm, the alarm address would be written in the trigger address. There are three methods to trigger: sending on rising edge, sending on falling edge and send when the bit changes.
294 -* **Recipient.** It is set in groups. You could send  multiple groups, and each group can have multiple recipients.
295 -* **Add CC.** Sends the current email to other recipients.
296 -* **Add secret delivery. ** Sends the current email to other recipients, but the recipient and cc recipients do not see the BCC recipient.
297 -* when sending an email, you must set a recipient. CC recipients and BCC recipients are not to be set. The total number of recipinet, CC recipients and BCC recipients is 40.
298 -* **Recipient priority. **Set the priority order of recipients to recipient, BCC, and CC.
295 +**1) Theme. **The value cannot be empty and case sensitive. The total length  cannot exceed 256 characters.
299 299  
297 +**2) Content of email. **The contents are divided into three combinations: text, alarm and variable. The list can contain only 32 items at most, and the total length of the preview cannot exceed 1024 items.
298 +
299 +* **Text. **You could directly edit the text of language 1 to language 3. If you need to set multiple languages, click "edit all text" to set. You may also select "Text library". The content is case sensitive, and the total length of English/Chinese characters/numbers/symbols does not exceed 253.
300 +* **Alarm. **You could select "bit alarm" or "word alarm" from the list. The content is from alarm text. if the alarm changes, the content changes with it. The content is case sensitive, and the total length of English/Chinese characters/numbers/symbols does not exceed 253.
301 +* **Variable. **Set the corresponding variable address. Read value or strings according to the specified format, and the read information will be displayed in the corresponding position in the mail content.
302 +
303 +**3) Preview. **Combine the content of current edited email and diaplay it for you to modify the content conviniently. The preview length cannot exceed 1024.
304 +
305 +**4) Sending method. **It is divided into timed send interval and bit address trigger tranmission. The two methods cannot be used at the same time.
306 +
307 +* timed send interval. After booting, the current system time is used to start calculating, and each time the time  is up, the information will be sent to the set recipient in the form of an email, and the minimum time should be set to 5 minutes. **Note: **The first boot is not sent.
308 +* Bit address trigger tranmission. When the set trigger address meets the trigger conditon, the information will be sent to the set recipient in the form of an email. If the content select alarm, the alarm address would be written in the trigger address. There are three methods to trigger: sending on rising edge, sending on falling edge and send when the bit changes.
309 +
310 +**5) Recipient.** It is set in groups. You could send  multiple groups, and each group can have multiple recipients.
311 +
312 +**6) Add CC.** Sends the current email to other recipients.
313 +
314 +**7) Add secret delivery. ** Sends the current email to other recipients, but the recipient and cc recipients do not see the BCC recipient.
315 +
316 +when sending an email, you must set a recipient. CC recipients and BCC recipients are not to be set. The total number of recipinet, CC recipients and BCC recipients is 40.
317 +
318 +**8) Recipient priority. **Set the priority order of recipients to recipient, BCC, and CC.
319 +
300 300  **✎Note: **If the recipient address you select exists in all three positions, it exist only in the highest priority position. For example, if the recipient of an email has aaa, the bcc has aaa, and the cc has aaa, then let aaa only be the recipient.
301 301  
302 -== Recipient group setting ==
322 +== **Recipient group setting** ==
303 303  
304 304  (% style="text-align:center" %)
305 305  [[image:邮件 4.png||class="img-thumbnail"]]
... ... @@ -308,7 +308,7 @@
308 308  1. **Group to send. **The groups that you send the emails to.
309 309  1. **Open recipinet settings.** Set the information of recipients, and add and subtract groups.
310 310  
311 -== Recipient setting ==
331 +== **Recipient setting** ==
312 312  
313 313  (% style="text-align:center" %)
314 314  [[image:邮件 5.png||class="img-thumbnail"]]
... ... @@ -324,7 +324,7 @@
324 324  1. **Nuber of group. **You could click the  up/down arrow to increase or devrease groups. The default number is 1. The maximum number is 16.
325 325  1. **Description. **To decribe the group information. The total length shall not exceed 32.
326 326  
327 -== Test sending settings ==
347 +== **Test sending settings** ==
328 328  
329 329  (% style="text-align:center" %)
330 330  [[image:邮件 7.png||class="img-thumbnail"]]
... ... @@ -392,17 +392,17 @@
392 392  |(% style="width:129px" %)416|(% style="width:946px" %)STARTTLS_NOT_SUPPORTED = The STARTTLS command is not supported by the server
393 393  |(% style="width:129px" %)417|(% style="width:946px" %)LOGIN_NOT_SUPPORTED = AUTH LOGIN is not supported by the server
394 394  
395 -== Email status ==
415 +== **Email status** ==
396 396  
397 -**Network disconnection error**
417 +**(1) Network disconnection error**
398 398  
399 399  If the fault is determined as a network disconnection error, the system does not delete the sent information and does not record the number of errors, and it would make an infinite send attempt.
400 400  
401 -**Custom rule error**
421 +**(2) Custom rule error**
402 402  
403 403  If the fault is determined as a custom rule error, delete the information.
404 404  
405 -**Server return error**
425 +**(3) Server return error**
406 406  
407 407  If the fault is determined as a server return error, then the error time add 1. It would try to send the email for 3 times. Regardless of whether the transmission is successful or not, it would delete the email to be sent. The test results are as follows.
408 408  
... ... @@ -416,17 +416,17 @@
416 416  |(% style="width:125px" %)sina|(% style="width:186px" %)50|(% style="width:765px" %)It can be sent again after a few minutes or a few hours, but cannont be received normally
417 417  |(% style="width:125px" %)gmail|(% style="width:186px" %)500|(% style="width:765px" %)No more delivery on that day
418 418  
419 -**Message Prompt**
439 +**(4) Message Prompt**
420 420  
421 421  1. If the email to be sent is deleted, a message will pop up.
422 422  1. If the email is sent successfully, a messge will pop up: "The email is sent successfully."
423 423  1. If the five symbols ',' , ' | ', '<', '>' and '&' appear in the fields set by the message prompt, the message prompt will display an abnormal message.
424 424  
425 -**Mail attachment**
445 +**(5) Mail attachment**
426 426  
427 427  Currently, the email attachment function only supports sending the specified alarm record (AlarmDataFile.db file), and does not support selecting content to send.
428 428  
429 -= USB keyboard =
449 += **USB keyboard** =
430 430  
431 431  (% class="wikigeneratedid" id="HIntroduction" %)
432 432  **Introduction**
... ... @@ -435,14 +435,14 @@
435 435  1. When the keyboard function is enabled, the "Cursor Display" function is enabled by default. The user could move the cursor through the "up, down, left and right buttons" of the keyboard, and then press the Enter key to select the object.
436 436  1. Multiple devices could be connected with HMI via USB HUB (up to 4 external devices), such as: mouse, keyboard, scanner, magnetic stripe reader, etc.
437 437  
438 -== Enable function ==
458 +== **Enable function** ==
439 439  
440 -In the software PIStudio, Click "Project" "Project settings" → "Extend", and check "Enable keyboard" in "Input device" settings area as below.
460 +In the software PIStudio, Click "Project" -> "Project settings"-> "Extend", and check "Enable keyboard" in "Input device" settings area as below.
441 441  
442 442  (% style="text-align:center" %)
443 -[[image:11.Advanced Function_html_f6cded728eedf4ce.png||height="567" width="501" class="img-thumbnail"]]
463 +[[image:11.Advanced Function_html_f6cded728eedf4ce.png||class="img-thumbnail" height="567" width="501"]]
444 444  
445 -== Configuration decription ==
465 +== **Configuration decription** ==
446 446  
447 447  1. When the keyboard function is enabled, the "Cursor Display" function is enabled by default. The user could move the cursor through the “up, down, left and right buttons” of the keyboard, and then press the Enter key to select the object;
448 448  1. NumLock: When NumLock key is not lit, the keypad number is not allowed to be input (offline simulation does not allow all numeric keys to be input, including the numeric keys on the left side of the keyboard);
... ... @@ -455,13 +455,13 @@
455 455  In practical application, the [Enable Keyboard] function could be combined with the related "system special address" to achieve multi-key combination operation.
456 456  
457 457  (% class="table-bordered" %)
458 -|=(% style="width: 114px;" %)**Address**|=(% style="width: 229px;" %)**Description**|=(% style="width: 733px;" %)**Function**
459 -|(% style="width:114px" %)HSW1073|(% style="width:229px" %)Keyboard key value|(% style="width:733px" %)(((
478 +|=**Address**|=**Description**|=**Function**
479 +|HSW1073|Keyboard key value|(((
460 460  The currently pressed key value is displayed. The key value is shown in Table 1
461 461  
462 462  (The Numeric/Character display object is not updated when it is being entered)
463 463  )))
464 -|(% style="width:114px" %)HSW1074|(% style="width:229px" %)Keyboard key status|(% style="width:733px" %)(((
484 +|HSW1074|Keyboard key status|(((
465 465  Display current key states
466 466  
467 467  ~=0: key release
... ... @@ -472,15 +472,15 @@
472 472  
473 473  (The Numeric/Character display object is not updated when it is being entered)
474 474  )))
475 -|(% style="width:114px" %)HSW1075|(% style="width:229px" %)Cursor speed|(% style="width:733px" %)Control the movement speed of the cursor, the range is 0~~100, the default is 20
476 -|(% style="width:114px" %)HSW1076|(% style="width:229px" %)X coordinate value of cursor|(% style="width:733px" %)The X value of the current position of the cursor, range: 0~~screen width-1
477 -|(% style="width:114px" %)HSW1077|(% style="width:229px" %)Y coordinate value of cursor|(% style="width:733px" %)The Y value of the current position of the cursor, range: 0~~screen height-1
478 -|(% style="width:114px" %)HSW1078|(% style="width:229px" %)The ASCII code of keyboard key|(% style="width:733px" %)(((
495 +|HSW1075|Cursor speed|Control the movement speed of the cursor, the range is 0~~100, the default is 20
496 +|HSW1076|X coordinate value of cursor|The X value of the current position of the cursor, range: 0~~screen width-1
497 +|HSW1077|Y coordinate value of cursor|The Y value of the current position of the cursor, range: 0~~screen height-1
498 +|HSW1078|The ASCII code of keyboard key|(((
479 479  Only the ASCII values of letters, numbers, and symbols are displayed. The ASCII value of the function keys is not displayed, as shown in Table 2
480 480  
481 481  (The Numeric/Character display object is not updated when it is being entered)
482 482  )))
483 -|(% style="width:114px" %)HSW1079|(% style="width:229px" %)Enable cursor position and Enter key mode|(% style="width:733px" %)(((
503 +|HSW1079|Enable cursor position and Enter key mode|(((
484 484  HSX1079.0 = 1: Set the cursor position according to HSW1076 and HSW1077 value;
485 485  
486 486  HSX1079.1 = 0: When Numeric/Character display object is entered, enter key is for end input instruction. When no Numeric/Character display object is entered, enter key is for normal click;
... ... @@ -561,91 +561,77 @@
561 561  
562 562  'HSW1073 key value
563 563  
564 -'HSW1074 key states
584 +'HSW1074 key states 0: released; 1: pressed; 2: Holding pressed
565 565  
566 -* 0: released;
567 -* 1: pressed;
568 -* 2: Holding pressed
569 -
570 570  'HSW1078 ASCII value of key
571 571  
572 -**Example 1**
588 +**(1) Example 1**
573 573  
574 -{{code language="lua"}}
575 -if @W_HSW1073 = 29 then                                            'Ctrl key value is 29
590 +if @W_HSW1073 = 29 then  'Ctrl key value is 29
576 576  
577 -    if @W_HSW1074 = 1 or @W_HSW1074 = 2               'Press Ctrl key
592 + if @W_HSW1074 = 1 or @W_HSW1074 = 2  'Press Ctrl key
578 578  
579 -              @W_HDW1000 = 1
594 + @W_HDW1000 = 1
580 580  
581 -    else                                                                               'Release Ctrl key
596 + else  'Release Ctrl key
582 582  
583 -              @W_HDW1000 = 0
598 + @W_HDW1000 = 0
584 584  
585 -    endif
600 + endif
586 586  
587 587  endif
588 -{{/code}}
589 589  
590 -**Example 2**
604 +**(2) Example 2**
591 591  
592 -{{code language="lua"}}
593 -if @W_HSW1073 = 59 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then              'F1 key value is 59
606 +if @W_HSW1073 = 59 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then  'F1 key value is 59
594 594  
595 -   if @W_HDW1000 = 1 then                                                                                          'Combination Ctrl + F1
608 + if @W_HDW1000 = 1 then  'Combination Ctrl + F1
596 596  
597 -         @W_HDW2000 = @W_HDW2000 + 1                                                                  'Function of combination key is HDW2000 + 1
610 + @W_HDW2000 = @W_HDW2000 + 1  'Function of combination key is HDW2000 + 1
598 598  
599 -    endif
612 + endif
600 600  
601 601  endif
602 -{{/code}}
603 603  
604 -**Example 3**
616 +**(3) Example 3**
605 605  
606 -{{code language="lua"}}
607 -if @W_HSW1073 = 60 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then              'the value of F2 is 60
618 +if @W_HSW1073 = 60 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then  'the value of F2 is 60
608 608  
609 -   if @W_HDW1000 = 1 then                                                                                          'Combination Ctrl + F2
620 + if @W_HDW1000 = 1 then  'Combination Ctrl + F2
610 610  
611 -            @W_HDW2000 = @W_HDW2000 - 1                                                                'Function of combination key is HDW2000 - 1
622 + @W_HDW2000 = @W_HDW2000 - 1  'Function of combination key is HDW2000 - 1
612 612  
613 -  endif
624 + endif
614 614  
615 615  endif
616 -{{/code}}
617 617  
618 -**Example 4**
628 +**(4) Example 4**
619 619  
620 -{{code language="lua"}}
621 -if AsString(@W_HSW1078) = "a" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then          'Page up
630 +if AsString(@W_HSW1078) = "a" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then  'Page up
622 622  
623 -    if @W_HSW13 > 0 then
632 + if @W_HSW13 > 0 then
624 624  
625 -           @W_HSW13 = @W_HSW13 - 1
634 + @W_HSW13 = @W_HSW13 - 1
626 626  
627 -    endif
636 + endif
628 628  
629 629  endif
630 -{{/code}}
631 631  
632 -**Example 5**
640 +**(5) Example 5**
633 633  
634 -{{code language="lua"}}
635 -if AsString(@W_HSW1078) = "b" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then          'Page down
642 +if AsString(@W_HSW1078) = "b" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then  'Page down
636 636  
637 -    @W_HSW13 = @W_HSW13 + 1
644 + @W_HSW13 = @W_HSW13 + 1
638 638  
639 -     if @W_HSW13 > 3 then
646 + if @W_HSW13 > 3 then
640 640  
641 -              @W_HSW13 = 3
648 + @W_HSW13 = 3
642 642  
643 -     endif
650 + endif
644 644  
645 645  endif
646 -{{/code}}
647 647  
648 -= **rtsp web camera** =
654 += **{{id name="_Toc29624"/}}rtsp web camera** =
649 649  
650 650  **Introduction**
651 651  
... ... @@ -652,17 +652,20 @@
652 652  1. An external IP Camera (web camera) can be used to display the screen captured by the it to achieve real-time monitoring of the scene of the equipment.
653 653  1. ONVIF protocol and H.264 coding camera (RTSP web camera) are supported.
654 654  
655 -**Supported Model:**
661 +**~ Supported Model:**
656 656  
657 -* Hikvision
658 -** DS-2CD1321D-I
659 -** DS-2CD3T20FD-I3W
660 -** DS-2CD1221D-I3
661 -** DS-2CV3Q21FD-IW
662 -* Dahua
663 -** DH-IPC-HFW1025D
664 -** DH-IPC-HFW1235M-I1
663 + 1) Hikvision
665 665  
665 +* DS-2CD1321D-I
666 +* DS-2CD3T20FD-I3W
667 +* DS-2CD1221D-I3
668 +* DS-2CV3Q21FD-IW
669 +
670 + 2) Dahua
671 +
672 +* DH-IPC-HFW1025D
673 +* DH-IPC-HFW1235M-I1
674 +
666 666  1. 8000 series HMI can view only **one **IP Camera monitoring screen at a time (only **one **camera object can be placed in a project).
667 667  1. 8000 series HMI can view only **four** IP Camera monitoring screen at a time (only **four **camera object can be placed in a project).
668 668  
... ... @@ -680,11 +680,11 @@
680 680  To configure the information of searches anf the records of search results. There are as follows.
681 681  
682 682  (% class="table-bordered" %)
683 -|(% style="width:226px" %)**Address**|(% style="width:533px" %)**Description**|(% style="width:240px" %)**Length**
684 -|(% style="width:226px" %)HDW200|(% style="width:533px" %)Username|(% style="width:240px" %)20 words
685 -|(% style="width:226px" %)HDW220|(% style="width:533px" %)Password|(% style="width:240px" %)20 words
686 -|(% style="width:226px" %)HDX240.0|(% style="width:533px" %)Falling edge trigger search|(% style="width:240px" %)1 bit
687 -|(% style="width:226px" %)HDX240.1|(% style="width:533px" %)(((
692 +|(% style="width:109px" %)**Address**|(% style="width:468px" %)**Description**|(% style="width:240px" %)**Length**
693 +|(% style="width:109px" %)HDW200|(% style="width:468px" %)Username|(% style="width:240px" %)20 words
694 +|(% style="width:109px" %)HDW220|(% style="width:468px" %)Password|(% style="width:240px" %)20 words
695 +|(% style="width:109px" %)HDX240.0|(% style="width:468px" %)Falling edge trigger search|(% style="width:240px" %)1 bit
696 +|(% style="width:109px" %)HDX240.1|(% style="width:468px" %)(((
688 688  Search status
689 689  
690 690  0: The search is complete.
... ... @@ -692,17 +692,17 @@
692 692  1: It is searching.
693 693  )))|(% style="width:240px" %)1 bit
694 694  |(% colspan="2" rowspan="1" style="width:109px" %)The first search result|(% style="width:240px" %)80 words
695 -|(% style="width:226px" %)HDW241|(% style="width:533px" %)IP address|(% style="width:240px" %)16 words
696 -|(% style="width:226px" %)HDW257|(% style="width:533px" %)(((
704 +|(% style="width:109px" %)HDW241|(% style="width:468px" %)IP address|(% style="width:240px" %)16 words
705 +|(% style="width:109px" %)HDW257|(% style="width:468px" %)(((
697 697  ~=1: correct password
698 698  
699 699  ~=0: wrong password
700 700  )))|(% style="width:240px" %)1 word
701 -|(% style="width:226px" %)HDW258|(% style="width:533px" %)Device serial number|(% style="width:240px" %)43 words
702 -|(% style="width:226px" %)HDW301|(% style="width:533px" %)Camera alias|(% style="width:240px" %)20 words
710 +|(% style="width:109px" %)HDW258|(% style="width:468px" %)Device serial number|(% style="width:240px" %)43 words
711 +|(% style="width:109px" %)HDW301|(% style="width:468px" %)Camera alias|(% style="width:240px" %)20 words
703 703  |(% colspan="2" rowspan="1" style="width:109px" %)The second search result|(% style="width:240px" %)80 words
704 -|(% style="width:226px" %)HDW321|(% style="width:533px" %)IP address|(% style="width:240px" %)16 words
705 -|(% style="width:226px" %)...|(% style="width:533px" %)...|(% style="width:240px" %)...
713 +|(% style="width:109px" %)HDW321|(% style="width:468px" %)IP address|(% style="width:240px" %)16 words
714 +|(% style="width:109px" %)...|(% style="width:468px" %)...|(% style="width:240px" %)...
706 706  
707 707  The username and password of function address need to entered manually. When searching for cameras, the username and password will be matched first, then each camera under the account will be retrieved, and the retrieved results will be stored in the response address. If the password is correct, the corresponding serial number would be displayed.
708 708  
... ... @@ -714,7 +714,7 @@
714 714  [[image:rtsp摄像头 2.png]]
715 715  
716 716  
717 -Compile and download project, please click [Search Camera] button to get camera information in LAN The username and password here need to be entered manually. During searching camera, it will try to use this username and password to log in IP camera and store the result of login. If the password is correct, the “password correct” address will be displayed as 1 and the device serial number will be displayed. If the “password correct” address is 0, the device serial number would not be displayed.
726 +3) Compile and download project, please click [Search Camera] button to get camera information in LAN The username and password here need to be entered manually. During searching camera, it will try to use this username and password to log in IP camera and store the result of login. If the password is correct, the “password correct” address will be displayed as 1 and the device serial number will be displayed. If the “password correct” address is 0, the device serial number would not be displayed.
718 718  
719 719  === **Function address** ===
720 720  
... ... @@ -757,24 +757,24 @@
757 757  
758 758  **Operating Procedures**
759 759  
760 -Fill the camera ID address with the camera serial number searched by the camera search module, and trigger the binding address to fill username and password.
769 +1) Fill the camera ID address with the camera serial number searched by the camera search module, and trigger the binding address to fill username and password.
761 761  
762 -* If the camera searching is disabled, then users need to manually enter the information of this camera, including username, password, and device serial number. Device serial number could be obtained by checking the label of camera.
771 +If the camera searching is disabled, then users need to manually enter the information of this camera, including username, password, and device serial number. Device serial number could be obtained by checking the label of camera.
763 763  
764 764  (% style="text-align:center" %)
765 -[[image:11.Advanced Function_html_9ba06415a43f4264.png||height="232" width="412" class="img-thumbnail"]]
774 +[[image:11.Advanced Function_html_9ba06415a43f4264.png||class="img-thumbnail" height="232" width="412"]]
766 766  
767 -* If the IP CAMERA was triggered successfully, we could see the monitor screen and we could also set a alias for the camera and control the movement of the camera(up, down, left and right, some IP camera could not support the movement) or the screenshot. These operations could not be performed if camera off.
776 +2) If the IP CAMERA was triggered successfully, we could see the monitor screen and we could also set a alias for the camera and control the movement of the camera(up, down, left and right, some IP camera could not support the movement) or the screenshot. These operations could not be performed if camera off.
768 768  
769 769  (% style="text-align:center" %)
770 -[[image:11.Advanced Function_html_5e0967606b906db1.jpg||height="250" width="333" class="img-thumbnail"]]
779 +[[image:11.Advanced Function_html_5e0967606b906db1.jpg||class="img-thumbnail" height="250" width="333"]]
771 771  
772 772  
773 773  **✎Note:**
774 774  
775 -* Camera configuration. When you get the camera, you need to activate the camera and enable the onvif protocol for the camera according to the user manual and tools provided by the camera manufacturer. If the configuration is not correct, the camera cannot be used on the HMI.
776 -* When reading camera information, you need to configure the user name and password for the camera. When multiple cameras are enabled, you are advised to set the user names and passwords of all cameras to be the same.
777 -* When using the camera function, ensure that the camera and HMI are on the same LAN. When the HMI is directly connected to the camera through a network cable, set both HMI and camera to static IP addresses as follows.
784 +1. Camera configuration. When you get the camera, you need to activate the camera and enable the onvif protocol for the camera according to the user manual and tools provided by the camera manufacturer. If the configuration is not correct, the camera cannot be used on the HMI.
785 +1. When reading camera information, you need to configure the user name and password for the camera. When multiple cameras are enabled, you are advised to set the user names and passwords of all cameras to be the same.
786 +1. When using the camera function, ensure that the camera and HMI are on the same LAN. When the HMI is directly connected to the camera through a network cable, set both HMI and camera to static IP addresses as follows.
778 778  
779 779  (% class="table-bordered" %)
780 780  |=(% style="width: 166px;" %) |=(% style="width: 256px;" %)HMI|=(% style="width: 332px;" %)Camera
... ... @@ -781,14 +781,15 @@
781 781  |(% style="width:166px" %)IP address|(% style="width:256px" %)192.168.1.1|(% style="width:332px" %)192.168.1.2
782 782  |(% style="width:166px" %)Gateway|(% style="width:256px" %)192.168.1.1|(% style="width:332px" %)192.168.1.1
783 783  
784 -* You could obtain the camera from the "Camera Search module" in "Project parameters" or manually fill in the address. You can obtain resources for the camera display object in the Camera Search module or manually enter the parameters.
785 -* You are advised to configure and confirm the user name and password of the camera before using it. Do not use the wrong user name (password) to search for or link to the camera. Once the wrong user name (password) is exceeded for a certain number of times, the camera will be locked. During the lock period, the camera will reject any connection for at least half an hour generally.
786 -* When monitoring HMI cameras, do not monitor the same camera at the same time. Otherwise, the monitoring screen may be lost.
787 -* When the camera is disconnected due to network reasons, the system wouyld try to reconnect the camera every 20 seconds.
788 -* The alias of the camera is saved in the user database. The alias in old project is retained when downloading new project, if [user database] is selected. Otherwise the it will be deleted.
793 +(% start="4" %)
794 +1. You could obtain the camera from the "Camera Search module" in "Project parameters" or manually fill in the address. You can obtain resources for the camera display object in the Camera Search module or manually enter the parameters.
795 +1. You are advised to configure and confirm the user name and password of the camera before using it. Do not use the wrong user name (password) to search for or link to the camera. Once the wrong user name (password) is exceeded for a certain number of times, the camera will be locked. During the lock period, the camera will reject any connection for at least half an hour generally.
796 +1. When monitoring HMI cameras, do not monitor the same camera at the same time. Otherwise, the monitoring screen may be lost.
797 +1. When the camera is disconnected due to network reasons, the system wouyld try to reconnect the camera every 20 seconds.
798 +1. The alias of the camera is saved in the user database. The alias in old project is retained when downloading new project, if [user database] is selected. Otherwise the it will be deleted.
789 789  
790 790  (% style="text-align:center" %)
791 -[[image:11.Advanced Function_html_804b6a35561fc436.png||height="367" width="600" class="img-thumbnail"]]
801 +[[image:11.Advanced Function_html_804b6a35561fc436.png||class="img-thumbnail" height="367" width="600"]]
792 792  
793 793  **Demo download link**
794 794  
... ... @@ -796,6 +796,9 @@
796 796  
797 797  = **LAN Monitoring** =
798 798  
809 +(% class="wikigeneratedid" id="H11.7.1Introduction" %)
810 +**Introduction**
811 +
799 799  WECON provides [HMI Monitor System] software for user to monitor PI3000 series HMI in Local area network (LAN).
800 800  
801 801  This function is only for the model with -O. For example PI3070N-O.
... ... @@ -802,11 +802,11 @@
802 802  
803 803  == **[HMI Monitor System] software** ==
804 804  
805 -**Device List: **It displays HMIs, that connected into this monitor software;
818 +(1) Device List: It displays HMIs, that connected into this monitor software;
806 806  
807 -**State Indicator:** It shows state of HMI, green means online, gray means offline;
820 +(2) State Indicator: It shows state of HMI, green means online, gray means offline;
808 808  
809 -**Operation Buttons: **It provides three operations for HMI device;
822 +(3) Operation Buttons: It provides three operations for HMI device;
810 810  
811 811  * Add: Click it to open add setting window;
812 812  * Delete: Click it to delete selected HMI device;
... ... @@ -813,96 +813,99 @@
813 813  * Monitor: Click it to open monitor window for selected HMI device;
814 814  
815 815  (% style="text-align:center" %)
816 -[[image:11.Advanced Function_html_fdfb5186d5dd123d.png||height="302" width="600" class="img-thumbnail"]]
829 +[[image:11.Advanced Function_html_fdfb5186d5dd123d.png||class="img-thumbnail" height="302" width="600"]]
817 817  
818 -== **Operating procedures** ==
831 +== **Operating Procedures** ==
819 819  
820 -Click [Add] button to open setting window;
833 +(1) Click [Add] button to open setting window;
821 821  
822 -Enter HMI IP and Note;
835 +(2) Enter HMI IP and Note;
823 823  
824 -Click [Connection test] button;
837 +(3) Click [Connection test] button;
825 825  
826 826  * If IP is correct, it will display tip as below;
827 827  
828 828  (% style="text-align:center" %)
829 -[[image:11.Advanced Function_html_130ed411da07f4c4.png||height="376" width="550" class="img-thumbnail"]]
842 +[[image:11.Advanced Function_html_130ed411da07f4c4.png||class="img-thumbnail" height="376" width="550"]]
830 830  
831 -* If IP is incorrect, it will display tip as below
844 +If IP is incorrect, it will display tip as below
832 832  
833 833  (% style="text-align:center" %)
834 -[[image:11.Advanced Function_html_878d04362f1b81b6.png||height="122" width="150" class="img-thumbnail"]]
847 +[[image:11.Advanced Function_html_878d04362f1b81b6.png||class="img-thumbnail" height="122" width="150"]]
835 835  
836 -**✎Note:** For using this function in PC, it requires the setup of LAN Monitoring Firewall, using Windows 7 system as example. **If this function works well in your PC, please ignore below content.**
849 +**✎Note:**
837 837  
851 +For using this function in PC, it requires the setup of LAN Monitoring Firewall, using Windows 7 system as example. **If this function works well in your PC, please ignore below content.**
852 +
838 838  **Solution 1: Disable Firmware Completely**
839 839  
840 -Open "Control Panel" and select "System Security".
855 +(1) Open [Control Panel] and select [System Security]
841 841  
842 842  (% style="text-align:center" %)
843 -[[image:11.Advanced Function_html_9616a538bd5b8890.png||height="426" width="600" class="img-thumbnail"]]
858 +[[image:11.Advanced Function_html_9616a538bd5b8890.png||class="img-thumbnail" height="426" width="600"]]
844 844  
845 -Select "Windows Firewall"
860 +(2) Select [Windows Firewall];
846 846  
847 847  (% style="text-align:center" %)
848 -[[image:11.Advanced Function_html_4ff5d9c605179616.png||height="427" width="600" class="img-thumbnail"]]
863 +[[image:11.Advanced Function_html_4ff5d9c605179616.png||class="img-thumbnail" height="427" width="600"]]
849 849  
850 -Select "turn Windows Firewall on or off"
865 +(3) Select [turn Windows Firewall on or off]
851 851  
852 852  (% style="text-align:center" %)
853 -[[image:11.Advanced Function_html_8cce81685e77dd93.png||height="532" width="850" class="img-thumbnail"]]
868 +[[image:11.Advanced Function_html_8cce81685e77dd93.png||class="img-thumbnail" height="532" width="850"]]
854 854  
855 -Select "Turn off Windows Firewall"
870 +(4) Select [Turn off Windows Firewall]
856 856  
857 857  (% style="text-align:center" %)
858 -[[image:11.Advanced Function_html_8e40bd24335bee5f.png||height="451" width="700" class="img-thumbnail"]]
873 +[[image:11.Advanced Function_html_8e40bd24335bee5f.png||class="img-thumbnail" height="451" width="700"]]
859 859  
860 860  **Solution 2: Do not close the firewall, but allow HMIUI to pass through the firewall**
861 861  
862 -Open Control Panel selection "system Security"
877 +(1) Open Control Panel selection [system Security]
863 863  
864 864  (% style="text-align:center" %)
865 -[[image:11.Advanced Function_html_4a5370b15f8344bf.png||height="363" width="550" class="img-thumbnail"]]
880 +[[image:11.Advanced Function_html_4a5370b15f8344bf.png||class="img-thumbnail" height="363" width="550"]]
866 866  
867 -Select "Windows Firewall"
882 +(2) Select [Windows Firewall]
868 868  
869 869  (% style="text-align:center" %)
870 -[[image:11.Advanced Function_html_3f00b4c76667d218.png||height="394" width="600" class="img-thumbnail"]]
885 +[[image:11.Advanced Function_html_3f00b4c76667d218.png||class="img-thumbnail" height="394" width="600"]]
871 871  
872 -Select "run a program or function through Windows Firewall"
887 +(3) Select [run a program or function through Windows Firewall]
873 873  
874 874  (% style="text-align:center" %)
875 -[[image:11.Advanced Function_html_2ce833853fe2fe08.png||height="422" width="600" class="img-thumbnail"]]
890 +[[image:11.Advanced Function_html_2ce833853fe2fe08.png||class="img-thumbnail" height="422" width="600"]]
876 876  
877 -Select "Allow to run another program".
892 +(4) Select [Allow to run another program].
878 878  
879 879  (% style="text-align:center" %)
880 -[[image:11.Advanced Function_html_49e43fd3e9e58bc3.png||height="401" width="600" class="img-thumbnail"]]
895 +[[image:11.Advanced Function_html_49e43fd3e9e58bc3.png||class="img-thumbnail" height="401" width="600"]]
881 881  
882 -Select "browse" in the pop-up dialog box.
897 +(5) Select [browse] in the pop-up dialog box
883 883  
884 884  (% style="text-align:center" %)
885 885  [[image:11.Advanced Function_html_714b05b4f66641fb.png||height="447" width="450"]]
886 886  
887 -Locate the HMIUI.exe file in the HMIUI directory under the installation path of the monitoring software, and double-click HMIUI.exe.
902 +(6) Locate the HMIUI.exe file in the HMIUI directory under the installation path of the monitoring software, and double-click HMIUI.exe
888 888  
889 889  (% style="text-align:center" %)
890 -[[image:11.Advanced Function_html_cdf52e5522e2e568.png||height="596" width="600" class="img-thumbnail"]]
905 +[[image:11.Advanced Function_html_cdf52e5522e2e568.png||class="img-thumbnail" height="596" width="600"]]
891 891  
892 -Select "add".
907 +(7) Select add
893 893  
894 894  (% style="text-align:center" %)
895 -[[image:11.Advanced Function_html_2cf5b5f0c9aa4f7a.png||height="467" width="535" class="img-thumbnail"]]
910 +[[image:11.Advanced Function_html_2cf5b5f0c9aa4f7a.png||class="img-thumbnail" height="467" width="535"]]
896 896  
897 -Check the corresponding options.
912 +(8) Check the corresponding options
898 898  
914 +
899 899  (% style="text-align:center" %)
900 -[[image:11.Advanced Function_html_ffc611cca1a173f9.png||height="361" width="600" class="img-thumbnail"]]
916 +[[image:11.Advanced Function_html_ffc611cca1a173f9.png||class="img-thumbnail" height="361" width="600"]]
901 901  
902 -select "OK".
918 +(9) select OK
903 903  
904 904  (% style="text-align:center" %)
905 -[[image:11.Advanced Function_html_934ebd63c53af3ee.png||height="442" width="600" class="img-thumbnail"]]
921 +[[image:11.Advanced Function_html_934ebd63c53af3ee.png||class="img-thumbnail" height="442" width="600"]]
906 906  
907 907  = **Remote access config** =
908 908  
... ... @@ -912,12 +912,12 @@
912 912  
913 913  The solution of WECON HMI remote access is "Everything is possible with one network, one HMI, one cable". No matter where the HMI is, users could easily remote access HMI through the network, to achieve exclude exceptions and resolve them in the first time. In local area network or remote Internet, users could make HMI connect to Ethernet by one cable without setting any parameters. All network settings could be set by WECON remote access system.
914 914  
915 -**Set the IP of HMI**
931 +**(1) Set the IP of HMI**
916 916  
917 917  (% style="text-align:center" %)
918 918  [[image:远程访问 1.png||class="img-thumbnail"]]
919 919  
920 -**Use mobile phones, computers, tablets, etc., open a browser, enter the IP, you could access the project in the HMI screen.**
936 +**(2) Use mobile phones, computers, tablets, etc., open a browser, enter the IP, you could access the project in the HMI screen.**
921 921  
922 922  * You are advised to use Chrome or Firefox. If you want to use Internet Explorer, use Internet Explorer 9 or later.
923 923  * 360, Sogou and other browsers need to use speed mode.
... ... @@ -924,11 +924,11 @@
924 924  * Support the iphone's own browser, or install a latest UC browser.
925 925  * As long as the browser supports HTML5.
926 926  
927 -**Access through the cloud**
943 +**(3) Access through the cloud**
928 928  
929 929  Access through the cloud platform, enter the machine code (the machine code of each HMI is independent) and model, then monitor the HMI remotely.
930 930  
931 -**Access through V-NET (ig series)**
947 +**(4) Access through V-NET (ig series)**
932 932  
933 933  Access through the V-NET, enter the machine code (the machine code of each HMI is independent) and the device password, bind the HMI, and monitor the HMI remotely.
934 934  
... ... @@ -936,7 +936,7 @@
936 936  
937 937  WECON PI8000 and advanced HMI with [-R], such as PI8070-R;
938 938  
939 -WECON Smart APP or WECON Cloud platform
955 +1) WECON Smart APP or WECON Cloud platform
940 940  
941 941  **User manual for WECON Smart and cloud platform download link**
942 942  
... ... @@ -944,27 +944,30 @@
944 944  
945 945  **FAQ**
946 946  
947 -* What is the difference between the-R model and the normal model?
948 -** The-R model can be accessed directly and unrestricted. Normal models need to buy cloudmonitoring products before access. The number of monitoring normal model is limitedaccording to the customer's purchase of cloud monitor packages.
949 -* How many customers could remote access HMI at the same time?
950 -** It supports max. 4 customers access HMI in the same time.
963 +1) What is the difference between the-R model and the normal model?
951 951  
965 +A: The-R model can be accessed directly and unrestricted. Normal models need to buy cloudmonitoring products before access. The number of monitoring normal model is limitedaccording to the customer's purchase of cloud monitor packages.
966 +
967 +2) How many customers could remote access HMI at the same time?
968 +
969 +A: It supports max. 4 customers access HMI in the same time.
970 +
952 952  = **Mulit-link** =
953 953  
954 954  == **Introduction** ==
955 955  
956 -The main principle of Multi-link is to use the method of Master&Slave to implement the One machine-Multiple screens by ethernet port. For example, one Master HMI connect to one Slave HMI, the Slave one can write or read value from PLC which is communicated with Master.
975 +1) The main principle of Multi-link is to use the method of Master&Slave to implement the One machine-Multiple screens by ethernet port. For example, one Master HMI connect to one Slave HMI, the Slave one can write or read value from PLC which is communicated with Master.
957 957  
958 -In Multi-link, there is only one Master, and all the other HMIs are Slaves. The Master HMI is the only one device communicate with PLC, and the data received from the PLC is transmitted to each slave through the host HMI(Master).
977 +2) In Multi-link, there is only one Master, and all the other HMIs are Slaves. The Master HMI is the only one device communicate with PLC, and the data received from the PLC is transmitted to each slave through the host HMI(Master).
959 959  
960 960  (% style="text-align:center" %)
961 961  [[image:1652345241521-592.png||class="img-thumbnail"]]
962 962  
963 -At present, the Multi-link is regarded as special function. So not any model HMI support it. Need the HMI come with the special machine code. The series support Multi-link function right now: General, HMI+, i Series. Multi link doesn’t support the online simulaion. PI3000/PI3000+/PI3000i series can only have one Slave when using this function, while PI8000/9000,PI8000+/PI9000+ series can use at most 5 Slaves.
982 +3) At present, the Multi-link is regarded as special function. So not any model HMI support it. Need the HMI come with the special machine code. The series support Multi-link function right now: General, HMI+, i Series. Multi link doesn’t support the online simulaion. PI3000/PI3000+/PI3000i series can only have one Slave when using this function, while PI8000/9000,PI8000+/PI9000+ series can use at most 5 Slaves.
964 964  
965 -== **PIStudio settings** ==
984 +== **PIStudio Settings** ==
966 966  
967 -Check to enable Multi-link, select the corresponding option. For example, if it is a slave HMI, select Slave.
986 +(1) Check to enable Multi-link, select the corresponding option. For example, if it is a slave HMI, select Slave.
968 968  
969 969  (% style="text-align:center" %)
970 970  [[image:多机互联.png||class="img-thumbnail"]]
... ... @@ -971,12 +971,12 @@
971 971  
972 972  
973 973  (% class="wikigeneratedid" %)
974 -Master IP address setting: Click "Project""Project settings""HMI IP", as below.
993 +(2) Master IP address setting: Click "Project"- "Project settings" - "HMI IP", as below.
975 975  
976 976  (% style="text-align:center" %)
977 -[[image:远程访问 1.png||height="516" width="594" class="img-thumbnail"]]
996 +[[image:远程访问 1.png||class="img-thumbnail" height="516" width="594"]]
978 978  
979 -== **Slave project** ==
998 +== **Slave Project** ==
980 980  
981 981  In order to let the fonts in the Slave and the Master consistent with each others, so Slave project needs to add one screen that can set the IP address of Master HMI for connecting to the Master, on the original the Master project. If Master project has components that use other font styles, and Slave project If there is no component corresponding to Master project, then the default font style SimSun would be displayed when the Multi-link is enabled. To avoid the Slave device prompts communication timeout message, you can add HSW9 = 1 in the initial script of Slave device.
982 982  
... ... @@ -999,72 +999,85 @@
999 999  
1000 1000  == **Notice** ==
1001 1001  
1002 -During the connection, if the Master is downloading program, there is a highly chances that the slave screen is abnormal, and the Gallery and imported pictures cannot be displayed.
1021 +1) During the connection, if the Master is downloading program, there is a highly chances that the slave screen is abnormal, and the Gallery and imported pictures cannot be displayed.
1003 1003  
1004 1004  After the download process of Master HMI is finished, Slave needs to be restarted to monitor normally.
1005 1005  
1006 -* If the Master and Slave are operated on any screen, the screen also will follow the changes and synchronize for other side.
1007 -** Using HSW12 = 1 on the Master, which can not affect each other.
1008 -* There is no momentary delay function for buttons.
1009 -* Multi-link version bit switch has no Min. holding time.
1010 -* PI3000 series can only have one Slave when using this function, while PI8000/9000 series can use this function at most 5 Slaves.
1011 -* Only supports Multi-link connection in the LAN network (local area network), or direct connection between Master and Slave.
1012 -* The Master and Slave projects must be consistent (mainly for keeping the font style used by the Master and Slave HMI consistent), and the Slave HMI always adds the configuration of the “Master IP address".
1013 -* After the special address is enabled, Slave will remotely monitor the interfaces from Master, and the source project will not be executed.
1025 +1. If the Master and Slave are operated on any screen, the screen also will follow the changes and synchronize for other side.
1014 1014  
1027 +Using HSW12 = 1 on the Master, which can not affect each other.
1028 +
1029 +1. There is no momentary delay function for buttons.
1030 +1. Multi-link version bit switch has no Min. holding time.
1031 +1. PI3000 series can only have one Slave when using this function, while PI8000/9000 series can use this function at most 5 Slaves.
1032 +1. Only supports Multi-link connection in the LAN network (local area network), or direct connection between Master and Slave.
1033 +1. The Master and Slave projects must be consistent (mainly for keeping the font style used by the Master and Slave HMI consistent), and the Slave HMI always adds the configuration of the “Master IP address".
1034 +1. After the special address is enabled, Slave will remotely monitor the interfaces from Master, and the source project will not be executed.
1035 +
1015 1015  ✎Note: Slave project only needs to ensure that there is "the HSW address of the Master HMI IP" and the font style used by the Master.
1016 1016  
1017 1017  = **V-NET Access (PC Side)** =
1018 1018  
1019 -== **Login interface** ==
1040 +== **Login Interface** ==
1020 1020  
1021 -Enter the platform, as shown in Figure 1:
1042 +~1. Enter the platform, as shown in Figure 1:
1022 1022  
1023 1023  New users need to register first.
1024 1024  
1025 -* The successfully registered account is the administrator account, which can bind the device and other operations.
1026 -* The user needs to remember the registered account and password, and able to log in simultaneously on the PC Client/APP.
1027 -* If the user forgets the password, he can click "Forgot Password" to reconfigure the password.
1046 +(1) The successfully registered account is the administrator account, which can bind the device and other operations.
1028 1028  
1048 +(2) The user needs to remember the registered account and password, and able to log in simultaneously on the PC Client/APP.
1049 +
1050 +(3) If the user forgets the password, he can click "Forgot Password" to reconfigure the password.
1051 +
1029 1029  (% style="text-align:center" %)
1030 1030  [[image:11.2-1.png||class="img-thumbnail"]]
1031 1031  
1032 1032  Figure 1
1033 1033  
1034 -Enter the account and password, and then click the "Login" button.
1057 +2. Enter the account and password, and then click the [Login] button.
1035 1035  
1036 -After successfully logging in, enter the "V-NET" interface, as shown in Figure 2. Add the HMI information you want to access through the "+" in the lower left corner.
1059 +3. After successfully logging in, enter the "V-NET" interface, as shown in Figure 2. Add the HMI information you want to access through the "+" in the lower left corner.
1037 1037  
1038 1038  (% style="text-align:center" %)
1039 -[[image:11.Advanced Function_html_7618c4f92465545c.png||height="670" width="1366" class="img-thumbnail"]]
1062 +[[image:11.Advanced Function_html_7618c4f92465545c.png||class="img-thumbnail" height="670" width="1366"]]
1040 1040  
1041 1041  Figure 2
1042 1042  
1043 -After the Add Device window pops up, enter the machine code and password of the device to add the device, as shown in Figure 3:   
1066 +4. After the Add Device window pops up, enter the machine code and password of the device to add the device, as shown in Figure 3:   
1044 1044  
1045 1045  (% style="text-align:center" %)
1046 -[[image:11.Advanced Function_html_9b4cc907cf4a8c13.png||height="502" width="601" class="img-thumbnail"]]
1069 +[[image:11.Advanced Function_html_9b4cc907cf4a8c13.png||class="img-thumbnail" height="502" width="601"]]
1047 1047  
1048 1048  Figure 3
1049 1049  
1050 -* **Device machine code:** Each HMI has a unique and independent machine code, which is used to identify every remote device. (When binding multiple devices at the same time, the device passwords must be the same. Only one machine code can be entered on one line. When entering multiple machine codes, use the "Enter" key to change the line. If the format is wrong, the binding operation will fail and error will occur). Method of obtain machine code:
1051 -** PIStudio → "Project" → "Tool"→ "Download" →Copy the machine code.        
1052 -** Long press the upper right corner of HMI to enter the backstage, you can see "Machine Id" in "Machine Info".       
1053 -** Obtain the machine code from the backlabel of the device.
1054 -* **Device password**: Refers to the Cloud access password, the default is 6 digits 8 (888888). Please refer to the cloud configuration if you first time binding the device.
1055 -** The length is 6 digits, English and special characters in English are allowed, spaces are not allowed, and cannot be empty.
1056 -* **Device alias:** Refers to the name recognition of device in the menu bar of V-NET.
1057 -** Maximum 12 digits, except ·_-+=}]",.?,;: ""”【】—()...! these Special characters allowed others are limited to input, no spaces or blanks are allowed.
1058 -** If the device is successfully bound, click OK, and it would prompt message: The device is bound successfully!
1073 +①Device machine code: Each HMI has a unique and independent machine code, which is used to identify every remote device.
1059 1059  
1060 -(% class="box infomessage" %)
1061 -(((
1075 + (When binding multiple devices at the same time, the device passwords must be the same. Only one machine code can be entered on one line. When entering multiple machine codes, use the "Enter" key to change the line. If the format is wrong, the binding operation will fail and error will occur)
1076 +
1077 + Method of obtain machine code:
1078 +
1079 + 1) PIStudio -[Project]-[Tool]-[Download]-Copy the machine code.        
1080 +
1081 + 2) Long press the upper right corner of HMI to enter the backstage, you can see [Machine Id] in "Machine Info".       
1082 +
1083 + 3) Obtain the machine code from the backlabel of the device.
1084 +
1085 +② Device password: Refers to the Cloud access password, the default is 6 digits 8 (888888). Please refer to the cloud configuration if you first time binding the device.
1086 +
1087 +(The length is 6 digits, English and special characters in English are allowed, spaces are not allowed, and cannot be empty).
1088 +
1089 +③ Device alias: Refers to the name recognition of device in the menu bar of V-NET.
1090 +
1091 +(Maximum 12 digits, except ·_-+=}]",.?,;: ""”【】—()...! these Special characters allowed others are limited to input, no spaces or blanks are allowed).
1092 +
1093 +5. If the device is successfully bound, click OK, and it would prompt message: The device is bound successfully!
1094 +
1062 1062  **✎Note: **If you bind multiple machine codes in batch, the device alias will use the input device alias as the prefix, and the system will automatically add a suffix. Example: Default group (device alias)_1 (automatically added suffix).
1063 -)))
1064 1064  
1065 -== **V-NET module** ==
1097 +== **V-NET Module** ==
1066 1066  
1067 -**Remote Monitoring**
1099 +{{id name="_GoBack"/}}1. Remote Monitoring
1068 1068  
1069 1069  The remote monitoring module can display the project page of the current screen in real time, and can operate the project on the web page, and the control of the screen. As shown in Figure 4:
1070 1070  
... ... @@ -1073,7 +1073,7 @@
1073 1073  
1074 1074   Figure 4
1075 1075  
1076 -**Data Viewing**
1108 +2. Data Viewing
1077 1077  
1078 1078  The data viewing module is divided into Communication port, Collection point, Alarm configuration, Alarm records, Data Record configuration , Data Record, etc. As shown in Figure 5:
1079 1079  
... ... @@ -1082,16 +1082,20 @@
1082 1082  
1083 1083  Figure 5
1084 1084  
1085 -The parameter configuration is as follows:
1117 + The parameter configuration is as follows:
1086 1086  
1087 -* Communication port : The communication port information, includes connection method and protocol name, can only be viewed, and cannot be added or modified. This info comes from the settings from HMI.
1088 -* Collect point:Data monitoring module of the device. The collection point is the monitoring data, and its read-write, write-only, and read-only permissions also come from the Tags settings from HMI.
1089 -* Note: You cannot add or delete collection points here. The read & write permissions of the collection points in the HMI will directly restrict the modification of the read & write permissions of the collection points by V-NET.
1090 -* Alarm configuration: Alarm records of the device, monitoring points cannot be added, confirming the Alarm record and exporting data can be performed.
1091 -* Data Record configuration: Data Record is historical data of the device, monitoring points cannot be added, curve and list viewing method are supported, and data records can be exported.
1119 + ①Communication port : The communication port information, includes connection method and protocol name, can only be viewed, and cannot be added or modified. This info comes from the settings from HMI.
1092 1092  
1093 -**Remote Download**
1121 + ②Collect point:Data monitoring module of the device. The collection point is the monitoring data, and its read-write, write-only, and read-only permissions also come from the Tags settings from HMI.
1094 1094  
1123 +Note: You cannot add or delete collection points here. The read & write permissions of the collection points in the HMI will directly restrict the modification of the read & write permissions of the collection points by V-NET.
1124 +
1125 + ③Alarm configuration: Alarm records of the device, monitoring points cannot be added, confirming the Alarm record and exporting data can be performed.
1126 +
1127 + ④Data Record configuration: Data Record is historical data of the device, monitoring points cannot be added, curve and list viewing method are supported, and data records can be exported.
1128 +
1129 +3. Remote Download
1130 +
1095 1095  This function allows application on the PC to download directly to PLC or HMI, as shown in Figure 6:
1096 1096  
1097 1097  (% style="text-align:center" %)
... ... @@ -1099,67 +1099,68 @@
1099 1099  
1100 1100  Figure 6
1101 1101  
1102 -(% class="box infomessage" %)
1103 -(((
1104 1104  **✎Note: **The pass through function of remote download is temporarily unavailable on the web page, and it can be used normally in PC client. The configuration is as follows:
1105 -)))
1106 1106  
1107 -PLC download (only for Pass-through)
1140 +(1) PLC download (only for Pass-through)
1108 1108  
1109 -* Click the setting (gear icon) in the upper right corner of PC Client, and a dialog will pop up. The red area is the COM port configuration when the PLC pass-through downloads. As shown in Figure 7:
1142 + Click the setting (gear icon) in the upper right corner of PC Client, and a dialog will pop up. The red area is the COM port configuration when the PLC pass-through downloads. As shown in Figure 7:
1110 1110  
1111 1111  (% style="text-align:center" %)
1112 -[[image:11.Advanced Function_html_870ebc5415b1a534.png||height="565" width="526" class="img-thumbnail"]]
1145 +[[image:11.Advanced Function_html_870ebc5415b1a534.png||class="img-thumbnail" height="565" width="526"]]
1113 1113  
1114 1114  Figure 7
1115 1115  
1116 -* After configuring the COM port, go to the remote downloaded, PLC download, to config the name, communication port, virtual serial port and other configurations as shown in Figure 6.
1149 + ②. After configuring the COM port, go to the remote downloaded, PLC download, to config the name, communication port, virtual serial port and other configurations as shown in Figure 6.
1117 1117  
1118 -HMI Download (only for Pass-through)
1151 +(2) HMI Download (only for Pass-through)
1119 1119  
1120 -* Click the setting (gear icon) button in the upper right corner of PC Client, and a dialog will pop up. The red area is the configuration of the HMI download tool. As shown in Figure 8:
1153 + ①. Click the setting (gear icon) button in the upper right corner of PC Client, and a dialog will pop up. The red area is the configuration of the HMI download tool. As shown in Figure 8:
1121 1121  
1122 1122  (% style="text-align:center" %)
1123 -[[image:11.Advanced Function_html_64e406f9862f887e.png||height="565" width="526" class="img-thumbnail"]]
1156 +[[image:11.Advanced Function_html_64e406f9862f887e.png||class="img-thumbnail" height="565" width="526"]]
1124 1124  
1125 1125  Figure 8
1126 1126  
1127 -* Click the setting (gear icon) button, a dialog box will pop up, and automatically detect and find the PIStudio that has been installed in PC and conforms to the version, as shown in Figure 9:
1128 -** Location: Display the installation path of the current PIStudio.
1129 -** Version: Corresponding to the version of the current PIStudio.
1130 -** Browse: Click to manually set the installation path of PIStudio.
1160 + ②. Click the setting (gear icon) button, a dialog box will pop up, and automatically detect and find the PIStudio that has been installed in PC and conforms to the version, as shown in Figure 9:
1131 1131  
1162 + Location: Display the installation path of the current PIStudio.
1163 +
1164 + Version: Corresponding to the version of the current PIStudio.
1165 +
1166 + Browse: Click to manually set the installation path of PIStudio.
1167 +
1132 1132  [[image:11.Advanced Function_html_df9946a5a7574454.png||height="349" width="642"]]
1133 1133  
1134 1134  Figure 9
1135 1135  
1136 -**Basic**
1172 +4. Basic
1137 1137  
1138 1138  In the "Basic" sub-page of Basic, HMI name, record reserved selection, password, location and remarks, etc. As shown in Figure 10:
1139 1139  
1140 1140  [[image:11.Advanced Function_html_c76828978cb6b697.png||height="670" width="1366"]] Figure 10
1141 1141  
1142 -The device name is an alias of HMI, which is mainly used for easy distinction.
1178 +(1) The device name is an alias of HMI, which is mainly used for easy distinction.
1143 1143  
1144 -Online status: You can click the refresh button to refresh the online status of the HMI.
1180 +(2) Online status: You can click the refresh button to refresh the online status of the HMI.
1145 1145  
1146 -Machine code: Each HMI has a unique and independent machine code.
1182 +(3) Machine code: Each HMI has a unique and independent machine code.
1147 1147  
1148 -Record reserved: Checking the corresponding options will let HMI to suspend updating the corresponding configuration after downloading a new project.
1184 +(4) Record reserved: Checking the corresponding options will let HMI to suspend updating the corresponding configuration after downloading a new project.
1149 1149  
1150 -Password: Refers to the cloud access password, the default is 6 digits 8 (888888); the cloud access password can be set and modified, the specific location is:
1186 +(5) Password:
1151 1151  
1152 -* V-NET → specified HMI → Baisc → "password” → modify and save, as shown in Figure 10.        
1153 -* "Project" → "Cloud" → "Basic" → "Password" → of PIStudio (only unbind HMI can be modified), see Cloud Configuration.
1188 + Refers to the cloud access password, the default is 6 digits 8 (888888); the cloud access password can be set and modified, the specific location is:
1154 1154  
1155 -Maximum storage of Alarm data: The maximum number of alarm data saved, with a range of 1 to 50000.    
1190 + ① V-NET —specified HMI—Baisc—Basic —"password”—modify and save, as shown in Figure 10.        
1156 1156  
1157 -Positioning:
1192 + ② [Project]-[Cloud]-Basic-" Password" of PIStudio (only unbind HMI can be modified), see Cloud Configuration.
1158 1158  
1159 -* Use the device base station positioning to locate.        
1160 -* Use manual positioning.
1194 +(6) Maximum storage of Alarm data: The maximum number of alarm data saved, with a range of 1-50000.    
1161 1161  
1162 -(% class="box infomessage" %)
1163 -(((
1196 +(7) Positioning:
1197 +
1198 + ①Use the device base station positioning to locate.        
1199 +
1200 + ②Use manual positioning.
1201 +
1164 1164  **✎Note:** After modifying the basic information of the device, you need to click Save below to save the modification successfully. If it is not saved successfully, please click Force Synchronization.
1165 -)))
file setting.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -21.2 KB
Content
视频功能部件配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -10.5 KB
Content