Changes for page 10 Advanced Function

Last modified by Jett on 2025/04/15 09:59

From version 18.1
edited by Mora Zhou
on 2023/11/21 16:30
Change comment: There is no comment for this version
To version 27.1
edited by Hunter
on 2024/04/28 18:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.Hunter
Content
... ... @@ -338,6 +338,8 @@
338 338  (% style="text-align:center" %)
339 339  [[image:邮件 7.png||class="img-thumbnail"]]
340 340  
341 +(% class="box infomessage" %)
342 +(((
341 341  (% class="wikigeneratedid" %)
342 342  **✎Note: **
343 343  
... ... @@ -346,6 +346,7 @@
346 346  1. When TOM mail is sender's mail, the name of it and the recipient tested must be English, otherwise the email would be returned.
347 347  1. When testing with Zoho mailbox, there was a delay of less than 3 minutes.
348 348  1. The custom errors for the test error is as follows.
351 +)))
349 349  
350 350  (% class="table-bordered" %)
351 351  |=(% style="width: 129px;" %)Error code|=(% style="width: 946px;" %)Cause of reason
... ... @@ -675,6 +675,16 @@
675 675  1. 8000 series HMI can view only **one **IP Camera monitoring screen at a time (only **one **camera object can be placed in a project).
676 676  1. 8000 series HMI can view only **four** IP Camera monitoring screen at a time (only **four **camera object can be placed in a project).
677 677  
681 +{{info}}
682 +✎Note:
683 +
684 +~1. General 8000 series HMI can only view **1** IP camera streaming media play at the same time(Only **1** camera object can be placed per project).
685 +
686 +2. General 9000 series HMI can only view **4** IP camera streaming media play at the same time(Only **4** camera objects can be placed per project).
687 +
688 +3. PI8000ig series HMI can only view **4** IP camera streaming media play at the same time(Only **4** camera objects can be placed per project).
689 +{{/info}}
690 +
678 678  == **Camera search** ==
679 679  
680 680  In the software PIStudio, Click "Project" -> "Project settings"-> "Extend", and check "Enable camera search module", shown as below.
... ... @@ -1172,3 +1172,110 @@
1172 1172  (((
1173 1173  **✎Note:** After modifying the basic information of the device, you need to click Save below to save the modification successfully. If it is not saved successfully, please click Force Synchronization.
1174 1174  )))
1188 +
1189 +== **RE Series Instructions** ==
1190 +
1191 +The RE series could easily meet advanced requirements such as real-time dashboard in industrial site.
1192 +
1193 +**Operation Steps**
1194 +
1195 +(1) New project
1196 +
1197 +1) Click [New Project];
1198 +
1199 +2) Name the project;
1200 +
1201 +3) Select [HMI Series] as [RE Series];
1202 +
1203 +4) Select [HMI Model] as [V-BOX RE-00/V-BOX RE-4G] (according to the actual needs);
1204 +
1205 +5) Optional Step: Select the resolution. (Due to the RE V-Box doesn't have the actual display, so it can select various resolutions)
1206 +
1207 +6) Optional Step: Same to the ig series, user could select the [[Screen style>>doc:PIStudio.04\.Software Menu.WebHome||anchor="HScreenstyle28Onlyigseries29"]] for RE series products;
1208 +
1209 +7) Click [OK] to finish the creation;
1210 +
1211 +(% style="text-align:center" %)
1212 +[[image:10-1remake.png]]
1213 +
1214 +8) Establish the communication protocol setup;
1215 +
1216 +(% style="text-align:center" %)
1217 +[[image:10-2.png]]
1218 +
1219 +(2) Enable Cloud
1220 +
1221 +Enable the Cloud function to let the RE V-Box able to access the V-NET platform.
1222 +
1223 +1) Click [Cloud];
1224 +
1225 +2) Click [Enable];
1226 +
1227 +3) Select the corresponding server;
1228 +
1229 +4) Click [OK] to finish the settings;
1230 +
1231 +(% style="text-align:center" %)
1232 +[[image:10-3.png]]
1233 +
1234 +(3) Project Download
1235 +
1236 +After project is done, user can compile and download the project into device. Same to the HMI, there are two download methods available for RE series, one is micro USB cable and the other one is the Ethernet.
1237 +
1238 +1) Click [Compile];
1239 +
1240 +2) Click [Download] to pop up the download tool;
1241 +
1242 +3) Select the download port;
1243 +
1244 +4) Click [PC to HMI];
1245 +
1246 +5) Click OK to reboot the device;
1247 +
1248 +(% style="text-align:center" %)
1249 +[[image:10-4.png]]
1250 +
1251 +{{info}}
1252 +✎Note: About the tool options' details, please go ahead: [[Download Tool>>||anchor="HDownloadTool"]]
1253 +{{/info}}
1254 +
1255 +(4) V-NET Platform Bind and browse
1256 +
1257 +About this part, please back to the heading [[V-NET Access>>doc:||anchor="HV-NETAccess28PCSide29"]] on the beginning or check the corresponding video: [[The ig V-NET Access>>https://youtu.be/j6i6KsCmnTE?list=PL_Bpnb2RgaktphrxRaCpFA809H_0xs-cU]](The general steps are same).
1258 +
1259 +1) Remote monitoring
1260 +
1261 +The remote monitoring module can display the project screen of the current HMI in real time and can operate the project on the web page.
1262 +
1263 +(% style="text-align:center" %)
1264 +[[image:10-5.png]]
1265 +
1266 +2) Data view
1267 +
1268 +It is divided into Communication port, Collection point, Alarm configuration, Alarm Recird, Data Record configuration, Data Record etc.
1269 +
1270 +About this part, please go to the [[Data Tool>>doc:PIStudio.08\.Basic Function.WebHome]] to check the details, or check the corresponding video: [[The ig Upload to Cloud Configuration>>https://youtu.be/vWXSF3qCwiQ]]
1271 +
1272 +(% style="text-align:center" %)
1273 +[[image:10-6.png]]
1274 +
1275 +3) Pass-through
1276 +
1277 +The pass-through function allows application files on the PC to maintenance the project program on site through RE devices.
1278 +
1279 +About this part, please go to the [[Device Pass-through>>doc:V-BOX.V-Net.Manual.3 V-NET Client.WebHome||anchor="HDevicePass-through"]] chapter to check the details,
1280 +
1281 +✎Note:
1282 +
1283 +* The pass-through function is unavailable on the browser web page, user need to change to V-NET Client to process the procedures;
1284 +* When the device is offline, button [Start Pass-through] cannot be clicked;
1285 +* When the device firmware is too low, button [Start Pass-through] cannot be clicked;
1286 +* Current user doesn't have permission for pass-through device or the device is shared by others, button [Start Pass-through] cannot be clicked;
1287 +* When the current user already has one device that is being penetrated, button [Start Pass-through] button cannot be clicked;
1288 +
1289 +4) LAN Monitoring
1290 +
1291 +Open the browser and enter the IP of the RE V-Box. Just like the following screenshot:
1292 +
1293 +(% style="text-align:center" %)
1294 +[[image:10-7.png]]
10-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +139.5 KB
Content
10-1remake.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +139.2 KB
Content
10-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +44.0 KB
Content
10-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +44.4 KB
Content
10-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.1 KB
Content
10-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +118.0 KB
Content
10-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +19.1 KB
Content
10-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +136.7 KB
Content