Changes for page 10 Advanced Function
Last modified by Jett on 2025/04/15 09:59
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Hunter - Content
-
... ... @@ -176,7 +176,7 @@ 176 176 177 177 **SMTP Settings** 178 178 179 -* **Sender Name: **Fill the sender's name, which is composed of Chinese characters, letters (case sensitive) and numbers. Butit canthefollowingspecial English symbols:',',';','"','<'. Maximum character length 32 is allowed.179 +* **Sender Name: **Fill the sender's name, which is composed of Chinese characters, letters (case sensitive) and numbers. However, it cannot contain some special English characters such as spaces( ), commas(,), semicolons(;), double quotes("), or less-than signs(<). Maximum character length 32 is allowed. 180 180 * **Password:** Fill in the password or authorization code of the mailbox. If the server needs to set the authorization code, the authorization code needs to be used. If the authorization code is not used, the password is used. Please refer to the SMTP service in the mailbox for the authorization code information. It cases sensitive, maximum character length 32 allowed in password. 181 181 * **Confirm Password: **Confirm the password or authorization code of the mailbox. 182 182 * **Email Address: **Fill in the sender's email address, case sensitive, maximum character length 32 allowed in it.Such as [[support@we-con.com.cn>>path:mailto:support@we-con.com.cn]]. ... ... @@ -338,6 +338,8 @@ 338 338 (% style="text-align:center" %) 339 339 [[image:邮件 7.png||class="img-thumbnail"]] 340 340 341 +(% class="box infomessage" %) 342 +((( 341 341 (% class="wikigeneratedid" %) 342 342 **✎Note: ** 343 343 ... ... @@ -346,6 +346,7 @@ 346 346 1. When TOM mail is sender's mail, the name of it and the recipient tested must be English, otherwise the email would be returned. 347 347 1. When testing with Zoho mailbox, there was a delay of less than 3 minutes. 348 348 1. The custom errors for the test error is as follows. 351 +))) 349 349 350 350 (% class="table-bordered" %) 351 351 |=(% style="width: 129px;" %)Error code|=(% style="width: 946px;" %)Cause of reason ... ... @@ -580,10 +580,10 @@ 580 580 581 581 **Example 1** 582 582 583 -{{code language=" lua"}}584 -if @W_HSW1073 = 29 then 586 +{{code language="vb"}} 587 +if @W_HSW1073 = 29 then 'Ctrl key value is 29 585 585 586 - if @W_HSW1074 = 1 or @W_HSW1074 = 2 589 + if @W_HSW1074 = 1 or @W_HSW1074 = 2 'Press Ctrl key 587 587 588 588 @W_HDW1000 = 1 589 589 ... ... @@ -598,12 +598,12 @@ 598 598 599 599 **Example 2** 600 600 601 -{{code language=" lua"}}604 +{{code language="Visual Basic"}} 602 602 if @W_HSW1073 = 59 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then 'F1 key value is 59 603 603 604 - if @W_HDW1000 = 1 then 607 + if @W_HDW1000 = 1 then 'Combination Ctrl + F1 605 605 606 - @W_HDW2000 = @W_HDW2000 + 1 609 + @W_HDW2000 = @W_HDW2000 + 1 'Function of combination key is HDW2000 + 1 607 607 608 608 endif 609 609 ... ... @@ -612,12 +612,12 @@ 612 612 613 613 **Example 3** 614 614 615 -{{code language=" lua"}}616 -if @W_HSW1073 = 60 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then 618 +{{code language="vb"}} 619 +if @W_HSW1073 = 60 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then 'the value of F2 is 60 617 617 618 - if @W_HDW1000 = 1 then 621 + if @W_HDW1000 = 1 then 'Combination Ctrl + F2 619 619 620 - @W_HDW2000 = @W_HDW2000 - 1 623 + @W_HDW2000 = @W_HDW2000 - 1 'Function of combination key is HDW2000 - 1 621 621 622 622 endif 623 623 ... ... @@ -626,7 +626,7 @@ 626 626 627 627 **Example 4** 628 628 629 -{{code language=" lua"}}632 +{{code language="vb"}} 630 630 if AsString(@W_HSW1078) = "a" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then 'Page up 631 631 632 632 if @W_HSW13 > 0 then ... ... @@ -640,7 +640,7 @@ 640 640 641 641 **Example 5** 642 642 643 -{{code language=" lua"}}646 +{{code language="vb"}} 644 644 if AsString(@W_HSW1078) = "b" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then 'Page down 645 645 646 646 @W_HSW13 = @W_HSW13 + 1 ... ... @@ -659,9 +659,9 @@ 659 659 **Introduction** 660 660 661 661 1. An external IP Camera (web camera) can be used to display the screen captured by the it to achieve real-time monitoring of the scene of the equipment. 662 -1. ONVIF protocol and H.264 coding camera (RTSP web camera) are supported. 665 +1. **ONVIF **protocol and **H.264** coding camera (RTSP web camera) are supported. 663 663 664 -** Supported Model:**667 +**Recommended Models:** 665 665 666 666 * Hikvision 667 667 ** DS-2CD1321D-I ... ... @@ -672,9 +672,24 @@ 672 672 ** DH-IPC-HFW1025D 673 673 ** DH-IPC-HFW1235M-I1 674 674 675 -1. 8000 series HMI can view only **one **IP Camera monitoring screen at a time (only **one **camera object can be placed in a project). 676 -1. 8000 series HMI can view only **four** IP Camera monitoring screen at a time (only **four **camera object can be placed in a project). 678 +**IP Camera Parameters Comparison for HMI Series** 677 677 680 +|=(% style="width: 300px;" %)HMI Series|=(% style="width: 157px;" %)System Version|=(% style="width: 320px;" %)Support IP Camera or Not|=(% style="width: 645px;" %)Number of Cameras 681 +|=(% style="width: 300px;" %)PI8000|(% style="width:157px" %)HMI V1.0/V2.0|(% style="width:320px" %)Yes|(% style="width:645px" %)1 682 +|=(% style="width: 300px;" %)PI9000|(% style="width:157px" %)HMI V1.0/V2.0|(% style="width:320px" %)Yes|(% style="width:645px" %)4 683 +|=(% style="width: 300px;" %)PI3000ig|(% style="width:157px" %)HMI V2.0|(% style="width:320px" %)No|(% style="width:645px" %)N/A 684 +|=(% style="width: 300px;" %)PI8000ig|(% style="width:157px" %)HMI V2.0|(% style="width:320px" %)Yes|(% style="width:645px" %)4 685 + 686 +{{info}} 687 +✎Note: 688 + 689 +~1. General 8000 series HMI can only view **1** IP camera streaming media play at the same time(Only **1** camera object can be placed per project). 690 + 691 +2. General 9000 series HMI can only view **4** IP camera streaming media play at the same time(Only **4** camera objects can be placed per project). 692 + 693 +3. PI8000ig series HMI can only view **4** IP camera streaming media play at the same time(Only **4** camera objects can be placed per project). 694 +{{/info}} 695 + 678 678 == **Camera search** == 679 679 680 680 In the software PIStudio, Click "Project" -> "Project settings"-> "Extend", and check "Enable camera search module", shown as below. ... ... @@ -1172,3 +1172,110 @@ 1172 1172 ((( 1173 1173 **✎Note:** After modifying the basic information of the device, you need to click Save below to save the modification successfully. If it is not saved successfully, please click Force Synchronization. 1174 1174 ))) 1193 + 1194 +== **RE Series Instructions** == 1195 + 1196 +The RE series could easily meet advanced requirements such as real-time dashboard in industrial site. 1197 + 1198 +**Operation Steps** 1199 + 1200 +(1) New project 1201 + 1202 +1) Click [New Project]; 1203 + 1204 +2) Name the project; 1205 + 1206 +3) Select [HMI Series] as [RE Series]; 1207 + 1208 +4) Select [HMI Model] as [V-BOX RE-00/V-BOX RE-4G] (according to the actual needs); 1209 + 1210 +5) Optional Step: Select the resolution. (Due to the RE V-Box doesn't have the actual display, so it can select various resolutions) 1211 + 1212 +6) Optional Step: Same to the ig series, user could select the [[Screen style>>doc:PIStudio.04\.Software Menu.WebHome||anchor="HScreenstyle28Onlyigseries29"]] for RE series products; 1213 + 1214 +7) Click [OK] to finish the creation; 1215 + 1216 +(% style="text-align:center" %) 1217 +[[image:10-1remake.png]] 1218 + 1219 +8) Establish the communication protocol setup; 1220 + 1221 +(% style="text-align:center" %) 1222 +[[image:10-2.png]] 1223 + 1224 +(2) Enable Cloud 1225 + 1226 +Enable the Cloud function to let the RE V-Box able to access the V-NET platform. 1227 + 1228 +1) Click [Cloud]; 1229 + 1230 +2) Click [Enable]; 1231 + 1232 +3) Select the corresponding server; 1233 + 1234 +4) Click [OK] to finish the settings; 1235 + 1236 +(% style="text-align:center" %) 1237 +[[image:10-3.png]] 1238 + 1239 +(3) Project Download 1240 + 1241 +After project is done, user can compile and download the project into device. Same to the HMI, there are two download methods available for RE series, one is micro USB cable and the other one is the Ethernet. 1242 + 1243 +1) Click [Compile]; 1244 + 1245 +2) Click [Download] to pop up the download tool; 1246 + 1247 +3) Select the download port; 1248 + 1249 +4) Click [PC to HMI]; 1250 + 1251 +5) Click OK to reboot the device; 1252 + 1253 +(% style="text-align:center" %) 1254 +[[image:10-4.png]] 1255 + 1256 +{{info}} 1257 +✎Note: About the tool options' details, please go ahead: [[Download Tool>>||anchor="HDownloadTool"]] 1258 +{{/info}} 1259 + 1260 +(4) V-NET Platform Bind and browse 1261 + 1262 +About this part, please back to the heading [[V-NET Access>>doc:||anchor="HV-NETAccess28PCSide29"]] on the beginning or check the corresponding video: [[The ig V-NET Access>>https://youtu.be/j6i6KsCmnTE?list=PL_Bpnb2RgaktphrxRaCpFA809H_0xs-cU]](The general steps are same). 1263 + 1264 +1) Remote monitoring 1265 + 1266 +The remote monitoring module can display the project screen of the current HMI in real time and can operate the project on the web page. 1267 + 1268 +(% style="text-align:center" %) 1269 +[[image:10-5.png]] 1270 + 1271 +2) Data view 1272 + 1273 +It is divided into Communication port, Collection point, Alarm configuration, Alarm Recird, Data Record configuration, Data Record etc. 1274 + 1275 +About this part, please go to the [[Data Tool>>doc:PIStudio.08\.Basic Function.WebHome]] to check the details, or check the corresponding video: [[The ig Upload to Cloud Configuration>>https://youtu.be/vWXSF3qCwiQ]] 1276 + 1277 +(% style="text-align:center" %) 1278 +[[image:10-6.png]] 1279 + 1280 +3) Pass-through 1281 + 1282 +The pass-through function allows application files on the PC to maintenance the project program on site through RE devices. 1283 + 1284 +About this part, please go to the [[Device Pass-through>>doc:V-BOX.V-Net.Manual.3 V-NET Client.WebHome||anchor="HDevicePass-through"]] chapter to check the details, 1285 + 1286 +✎Note: 1287 + 1288 +* The pass-through function is unavailable on the browser web page, user need to change to V-NET Client to process the procedures; 1289 +* When the device is offline, button [Start Pass-through] cannot be clicked; 1290 +* When the device firmware is too low, button [Start Pass-through] cannot be clicked; 1291 +* Current user doesn't have permission for pass-through device or the device is shared by others, button [Start Pass-through] cannot be clicked; 1292 +* When the current user already has one device that is being penetrated, button [Start Pass-through] button cannot be clicked; 1293 + 1294 +4) LAN Monitoring 1295 + 1296 +Open the browser and enter the IP of the RE V-Box. Just like the following screenshot: 1297 + 1298 +(% style="text-align:center" %) 1299 +[[image:10-7.png]]
- 10-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +139.5 KB - Content
- 10-1remake.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +139.2 KB - Content
- 10-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.0 KB - Content
- 10-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.4 KB - Content
- 10-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.1 KB - Content
- 10-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +118.0 KB - Content
- 10-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.1 KB - Content
- 10-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +136.7 KB - Content