Changes for page 10 Advanced Function
Last modified by Jett on 2025/04/15 09:59
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1178,6 +1178,100 @@ 1178 1178 1179 1179 == **RE Series Instructions** == 1180 1180 1181 -The 1181 +The RE series could easily meet advanced requirements such as real-time dashboard in industrial site. 1182 1182 1183 - 1183 +**Operation Steps** 1184 + 1185 +(1) New project 1186 + 1187 +1) Click [New Project]; 1188 + 1189 +2) Name the project; 1190 + 1191 +3) Select [HMI Series] as [RE Series]; 1192 + 1193 +4) Select [HMI Model] as [V-BOX RE-00/V-BOX RE-4G] (according to the actual needs); 1194 + 1195 +5) Optional Step: Select the resolution. (Due to the RE V-Box doesn't have the actual display, so it can select various resolutions) 1196 + 1197 +6) Optional Step: Same to the ig series, user could select the [[Screen style>>doc:PIStudio.04\.Software Menu.WebHome||anchor="HScreenstyle28Onlyigseries29"]] for RE series products; 1198 + 1199 +7) Click [OK] to finish the creation; 1200 + 1201 +(% style="text-align:center" %) 1202 +[[image:10-1remake.png]] 1203 + 1204 +8) Establish the communication protocol setup; 1205 + 1206 +(% style="text-align:center" %) 1207 +[[image:10-2.png]] 1208 + 1209 +(2) Enable Cloud 1210 + 1211 +Enable the Cloud function to let the RE V-Box able to access the V-NET platform. 1212 + 1213 +1) Click [Cloud]; 1214 + 1215 +2) Click [Enable]; 1216 + 1217 +3) Select the corresponding server; 1218 + 1219 +4) Click [OK] to finish the settings; 1220 + 1221 +(% style="text-align:center" %) 1222 +[[image:10-3.png]] 1223 + 1224 +(3) Project Download 1225 + 1226 +After project is done, user can compile and download the project into device. Same to the HMI, there are two download methods available for RE series, one is micro USB cable and the other one is the Ethernet. 1227 + 1228 +1) Click [Compile]; 1229 + 1230 +2) Click [Download] to pop up the download tool; 1231 + 1232 +3) Select the download port; 1233 + 1234 +4) Click [PC to HMI]; 1235 + 1236 +5) Click OK to reboot the device; 1237 + 1238 +(% style="text-align:center" %) 1239 +[[image:10-4.png]] 1240 + 1241 +{{info}} 1242 +✎Note: About the tool options' details, please go ahead: [[Download Tool>>||anchor="HDownloadTool"]] 1243 +{{/info}} 1244 + 1245 +(4) V-NET Platform Bind and browse 1246 + 1247 +About this part, please back to the heading [[V-NET Access>>doc:||anchor="HV-NETAccess28PCSide29"]] on the beginning or check the corresponding video: [[The ig V-NET Access>>https://youtu.be/j6i6KsCmnTE?list=PL_Bpnb2RgaktphrxRaCpFA809H_0xs-cU]](The general steps are same). 1248 + 1249 +1) Remote monitoring 1250 + 1251 +The remote monitoring module can display the project screen of the current HMI in real time and can operate the project on the web page. 1252 + 1253 +(% style="text-align:center" %) 1254 +[[image:10-5.png]] 1255 + 1256 +2) Data view 1257 + 1258 +It is divided into Communication port, Collection point, Alarm configuration, Alarm Recird, Data Record configuration, Data Record etc. 1259 + 1260 +About this part, please go to the [[Data Tool>>doc:PIStudio.08\.Basic Function.WebHome]] to check the details, or check the corresponding video: [[The ig Upload to Cloud Configuration>>https://youtu.be/vWXSF3qCwiQ]] 1261 + 1262 +(% style="text-align:center" %) 1263 +[[image:10-6.png]] 1264 + 1265 +3) Pass-through 1266 + 1267 +The pass-through function allows application files on the PC to maintenance the project program on site through RE devices. 1268 + 1269 +About this part, please go to the [[Device Pass-through>>doc:V-BOX.V-Net.Manual.3 V-NET Client.WebHome||anchor="HDevicePass-through"]] chapter to check the details, 1270 + 1271 +✎Note: 1272 + 1273 +* The pass-through function is unavailable on the browser web page, user need to change to V-NET Client to process the procedures; 1274 +* When the device is offline, button [Start Pass-through] cannot be clicked; 1275 +* When the device firmware is too low, button [Start Pass-through] cannot be clicked; 1276 +* Current user doesn't have permission for pass-through device or the device is shared by others, button [Start Pass-through] cannot be clicked; 1277 +* When the current user already has one device that is being penetrated, button [Start Pass-through] button cannot be clicked;
- 10-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +139.5 KB - Content
- 10-1remake.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +139.2 KB - Content
- 10-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.0 KB - Content
- 10-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.4 KB - Content
- 10-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.1 KB - Content
- 10-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +118.0 KB - Content
- 10-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.1 KB - Content