Changes for page 10 Advanced Function
Last modified by Jett on 2025/04/15 09:59
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -678,6 +678,16 @@ 678 678 1. 8000 series HMI can view only **one **IP Camera monitoring screen at a time (only **one **camera object can be placed in a project). 679 679 1. 8000 series HMI can view only **four** IP Camera monitoring screen at a time (only **four **camera object can be placed in a project). 680 680 681 +{{info}} 682 +✎Note: 683 + 684 +~1. General 8000 series HMI can only view **1** IP camera streaming media play at the same time(Only **1** camera object can be placed per project). 685 + 686 +2. General 9000 series HMI can only view **4** IP camera streaming media play at the same time(Only **4** camera objects can be placed per project). 687 + 688 +3. PI8000ig series HMI can only view **4** IP camera streaming media play at the same time(Only **4** camera objects can be placed per project). 689 +{{/info}} 690 + 681 681 == **Camera search** == 682 682 683 683 In the software PIStudio, Click "Project" -> "Project settings"-> "Extend", and check "Enable camera search module", shown as below. ... ... @@ -1186,15 +1186,99 @@ 1186 1186 1187 1187 1) Click [New Project]; 1188 1188 1189 -2) Select[HMI Series]as [RE Series];1199 +2) Name the project; 1190 1190 1191 -3) Select [HMI Model] as [V-BOXRE-00/V-BOXRE-4G] (according to theactual needs);1201 +3) Select [HMI Series] as [RE Series]; 1192 1192 1193 -4) Optional:Sameotheig series,usercouldselect thescreen stylefor RE series products;1203 +4) Select [HMI Model] as [V-BOX RE-00/V-BOX RE-4G] (according to the actual needs); 1194 1194 1195 -5) Click[OK]tofinish the creation;1205 +5) Optional Step: Select the resolution. (Due to the RE V-Box doesn't have the actual display, so it can select various resolutions) 1196 1196 1207 +6) Optional Step: Same to the ig series, user could select the [[Screen style>>doc:PIStudio.04\.Software Menu.WebHome||anchor="HScreenstyle28Onlyigseries29"]] for RE series products; 1208 + 1209 +7) Click [OK] to finish the creation; 1210 + 1197 1197 (% style="text-align:center" %) 1198 -[[image:10-1.png]] 1212 +[[image:10-1remake.png]] 1199 1199 1200 - 1214 +8) Establish the communication protocol setup; 1215 + 1216 +(% style="text-align:center" %) 1217 +[[image:10-2.png]] 1218 + 1219 +(2) Enable Cloud 1220 + 1221 +Enable the Cloud function to let the RE V-Box able to access the V-NET platform. 1222 + 1223 +1) Click [Cloud]; 1224 + 1225 +2) Click [Enable]; 1226 + 1227 +3) Select the corresponding server; 1228 + 1229 +4) Click [OK] to finish the settings; 1230 + 1231 +(% style="text-align:center" %) 1232 +[[image:10-3.png]] 1233 + 1234 +(3) Project Download 1235 + 1236 +After project is done, user can compile and download the project into device. Same to the HMI, there are two download methods available for RE series, one is micro USB cable and the other one is the Ethernet. 1237 + 1238 +1) Click [Compile]; 1239 + 1240 +2) Click [Download] to pop up the download tool; 1241 + 1242 +3) Select the download port; 1243 + 1244 +4) Click [PC to HMI]; 1245 + 1246 +5) Click OK to reboot the device; 1247 + 1248 +(% style="text-align:center" %) 1249 +[[image:10-4.png]] 1250 + 1251 +{{info}} 1252 +✎Note: About the tool options' details, please go ahead: [[Download Tool>>||anchor="HDownloadTool"]] 1253 +{{/info}} 1254 + 1255 +(4) V-NET Platform Bind and browse 1256 + 1257 +About this part, please back to the heading [[V-NET Access>>doc:||anchor="HV-NETAccess28PCSide29"]] on the beginning or check the corresponding video: [[The ig V-NET Access>>https://youtu.be/j6i6KsCmnTE?list=PL_Bpnb2RgaktphrxRaCpFA809H_0xs-cU]](The general steps are same). 1258 + 1259 +1) Remote monitoring 1260 + 1261 +The remote monitoring module can display the project screen of the current HMI in real time and can operate the project on the web page. 1262 + 1263 +(% style="text-align:center" %) 1264 +[[image:10-5.png]] 1265 + 1266 +2) Data view 1267 + 1268 +It is divided into Communication port, Collection point, Alarm configuration, Alarm Recird, Data Record configuration, Data Record etc. 1269 + 1270 +About this part, please go to the [[Data Tool>>doc:PIStudio.08\.Basic Function.WebHome]] to check the details, or check the corresponding video: [[The ig Upload to Cloud Configuration>>https://youtu.be/vWXSF3qCwiQ]] 1271 + 1272 +(% style="text-align:center" %) 1273 +[[image:10-6.png]] 1274 + 1275 +3) Pass-through 1276 + 1277 +The pass-through function allows application files on the PC to maintenance the project program on site through RE devices. 1278 + 1279 +About this part, please go to the [[Device Pass-through>>doc:V-BOX.V-Net.Manual.3 V-NET Client.WebHome||anchor="HDevicePass-through"]] chapter to check the details, 1280 + 1281 +✎Note: 1282 + 1283 +* The pass-through function is unavailable on the browser web page, user need to change to V-NET Client to process the procedures; 1284 +* When the device is offline, button [Start Pass-through] cannot be clicked; 1285 +* When the device firmware is too low, button [Start Pass-through] cannot be clicked; 1286 +* Current user doesn't have permission for pass-through device or the device is shared by others, button [Start Pass-through] cannot be clicked; 1287 +* When the current user already has one device that is being penetrated, button [Start Pass-through] button cannot be clicked; 1288 + 1289 +4) LAN Monitoring 1290 + 1291 +Open the browser and enter the IP of the RE V-Box. Just like the following screenshot: 1292 + 1293 +(% style="text-align:center" %) 1294 +[[image:10-7.png]]
- 10-1remake.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +139.2 KB - Content
- 10-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.0 KB - Content
- 10-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.4 KB - Content
- 10-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.1 KB - Content
- 10-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +118.0 KB - Content
- 10-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.1 KB - Content
- 10-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +136.7 KB - Content