Changes for page 10 Advanced Function

Last modified by Jett on 2025/04/15 09:59

From version 21.2
edited by Hunter
on 2024/02/04 17:15
Change comment: There is no comment for this version
To version 30.1
edited by Devin Chen
on 2024/06/04 15:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.DevinChen
Content
... ... @@ -176,7 +176,7 @@
176 176  
177 177  **SMTP Settings**
178 178  
179 -* **Sender Name: **Fill the sender's name, which is composed of Chinese characters, letters (case sensitive) and numbers. But it can not contain the following special English symbols ',', ';', '"', '<'. Maximum character length 32 is allowed.
179 +* **Sender Name: **Fill the sender's name, which is composed of Chinese characters, letters (case sensitive) and numbers. However, it cannot contain some special English characters such as spaces( ), commas(,), semicolons(;), double quotes("), or less-than signs(<). Maximum character length 32 is allowed.
180 180  * **Password:** Fill in the password or authorization code of the mailbox. If the server needs to set the authorization code, the authorization code needs to be used. If the authorization code is not used, the password is used. Please refer to the SMTP service in the mailbox for the authorization code information. It cases sensitive, maximum character length 32 allowed in password.
181 181  * **Confirm Password: **Confirm the password or authorization code of the mailbox.
182 182  * **Email Address: **Fill in the sender's email address, case sensitive, maximum character length 32 allowed in it.Such as [[support@we-con.com.cn>>path:mailto:support@we-con.com.cn]].
... ... @@ -583,10 +583,10 @@
583 583  
584 584  **Example 1**
585 585  
586 -{{code language="lua"}}
587 -if @W_HSW1073 = 29 then                                            'Ctrl key value is 29
586 +{{code language="vb"}}
587 +if @W_HSW1073 = 29 then      'Ctrl key value is 29
588 588  
589 -    if @W_HSW1074 = 1 or @W_HSW1074 = 2               'Press Ctrl key
589 +    if @W_HSW1074 = 1 or @W_HSW1074 = 2       'Press Ctrl key
590 590  
591 591                @W_HDW1000 = 1
592 592  
... ... @@ -601,12 +601,12 @@
601 601  
602 602  **Example 2**
603 603  
604 -{{code language="lua"}}
604 +{{code language="Visual Basic"}}
605 605  if @W_HSW1073 = 59 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then              'F1 key value is 59
606 606  
607 -   if @W_HDW1000 = 1 then                                                                                          'Combination Ctrl + F1
607 +   if @W_HDW1000 = 1 then                                                                 'Combination Ctrl + F1
608 608  
609 -         @W_HDW2000 = @W_HDW2000 + 1                                                                  'Function of combination key is HDW2000 + 1
609 +         @W_HDW2000 = @W_HDW2000 + 1                                  'Function of combination key is HDW2000 + 1
610 610  
611 611      endif
612 612  
... ... @@ -615,12 +615,12 @@
615 615  
616 616  **Example 3**
617 617  
618 -{{code language="lua"}}
619 -if @W_HSW1073 = 60 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then              'the value of F2 is 60
618 +{{code language="vb"}}
619 +if @W_HSW1073 = 60 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then            'the value of F2 is 60
620 620  
621 -   if @W_HDW1000 = 1 then                                                                                          'Combination Ctrl + F2
621 +   if @W_HDW1000 = 1 then                                                     'Combination Ctrl + F2
622 622  
623 -            @W_HDW2000 = @W_HDW2000 - 1                                                                'Function of combination key is HDW2000 - 1
623 +            @W_HDW2000 = @W_HDW2000 - 1                                  'Function of combination key is HDW2000 - 1
624 624  
625 625    endif
626 626  
... ... @@ -629,7 +629,7 @@
629 629  
630 630  **Example 4**
631 631  
632 -{{code language="lua"}}
632 +{{code language="vb"}}
633 633  if AsString(@W_HSW1078) = "a" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then          'Page up
634 634  
635 635      if @W_HSW13 > 0 then
... ... @@ -643,7 +643,7 @@
643 643  
644 644  **Example 5**
645 645  
646 -{{code language="lua"}}
646 +{{code language="vb"}}
647 647  if AsString(@W_HSW1078) = "b" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then          'Page down
648 648  
649 649      @W_HSW13 = @W_HSW13 + 1
... ... @@ -675,9 +675,16 @@
675 675  ** DH-IPC-HFW1025D
676 676  ** DH-IPC-HFW1235M-I1
677 677  
678 -1. 8000 series HMI can view only **one **IP Camera monitoring screen at a time (only **one **camera object can be placed in a project).
679 -1. 8000 series HMI can view only **four** IP Camera monitoring screen at a time (only **four **camera object can be placed in a project).
678 +{{info}}
679 +✎Note:
680 680  
681 +~1. General 8000 series HMI can only view **1** IP camera streaming media play at the same time(Only **1** camera object can be placed per project).
682 +
683 +2. General 9000 series HMI can only view **4** IP camera streaming media play at the same time(Only **4** camera objects can be placed per project).
684 +
685 +3. PI8000ig series HMI can only view **4** IP camera streaming media play at the same time(Only **4** camera objects can be placed per project).
686 +{{/info}}
687 +
681 681  == **Camera search** ==
682 682  
683 683  In the software PIStudio, Click "Project" -> "Project settings"-> "Extend", and check "Enable camera search module", shown as below.
... ... @@ -1212,4 +1212,73 @@
1212 1212  
1213 1213  1) Click [Cloud];
1214 1214  
1215 -2)
1222 +2) Click [Enable];
1223 +
1224 +3) Select the corresponding server;
1225 +
1226 +4) Click [OK] to finish the settings;
1227 +
1228 +(% style="text-align:center" %)
1229 +[[image:10-3.png]]
1230 +
1231 +(3) Project Download
1232 +
1233 +After project is done, user can compile and download the project into device. Same to the HMI, there are two download methods available for RE series, one is micro USB cable and the other one is the Ethernet.
1234 +
1235 +1) Click [Compile];
1236 +
1237 +2) Click [Download] to pop up the download tool;
1238 +
1239 +3) Select the download port;
1240 +
1241 +4) Click [PC to HMI];
1242 +
1243 +5) Click OK to reboot the device;
1244 +
1245 +(% style="text-align:center" %)
1246 +[[image:10-4.png]]
1247 +
1248 +{{info}}
1249 +✎Note: About the tool options' details, please go ahead: [[Download Tool>>||anchor="HDownloadTool"]]
1250 +{{/info}}
1251 +
1252 +(4) V-NET Platform Bind and browse
1253 +
1254 +About this part, please back to the heading [[V-NET Access>>doc:||anchor="HV-NETAccess28PCSide29"]] on the beginning or check the corresponding video: [[The ig V-NET Access>>https://youtu.be/j6i6KsCmnTE?list=PL_Bpnb2RgaktphrxRaCpFA809H_0xs-cU]](The general steps are same).
1255 +
1256 +1) Remote monitoring
1257 +
1258 +The remote monitoring module can display the project screen of the current HMI in real time and can operate the project on the web page.
1259 +
1260 +(% style="text-align:center" %)
1261 +[[image:10-5.png]]
1262 +
1263 +2) Data view
1264 +
1265 +It is divided into Communication port, Collection point, Alarm configuration, Alarm Recird, Data Record configuration, Data Record etc.
1266 +
1267 +About this part, please go to the [[Data Tool>>doc:PIStudio.08\.Basic Function.WebHome]] to check the details, or check the corresponding video: [[The ig Upload to Cloud Configuration>>https://youtu.be/vWXSF3qCwiQ]]
1268 +
1269 +(% style="text-align:center" %)
1270 +[[image:10-6.png]]
1271 +
1272 +3) Pass-through
1273 +
1274 +The pass-through function allows application files on the PC to maintenance the project program on site through RE devices.
1275 +
1276 +About this part, please go to the [[Device Pass-through>>doc:V-BOX.V-Net.Manual.3 V-NET Client.WebHome||anchor="HDevicePass-through"]] chapter to check the details,
1277 +
1278 +✎Note:
1279 +
1280 +* The pass-through function is unavailable on the browser web page, user need to change to V-NET Client to process the procedures;
1281 +* When the device is offline, button [Start Pass-through] cannot be clicked;
1282 +* When the device firmware is too low, button [Start Pass-through] cannot be clicked;
1283 +* Current user doesn't have permission for pass-through device or the device is shared by others, button [Start Pass-through] cannot be clicked;
1284 +* When the current user already has one device that is being penetrated, button [Start Pass-through] button cannot be clicked;
1285 +
1286 +4) LAN Monitoring
1287 +
1288 +Open the browser and enter the IP of the RE V-Box. Just like the following screenshot:
1289 +
1290 +(% style="text-align:center" %)
1291 +[[image:10-7.png]]
10-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +44.4 KB
Content
10-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.1 KB
Content
10-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +118.0 KB
Content
10-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +19.1 KB
Content
10-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +136.7 KB
Content