Wiki source code of 10 Advanced Function

Version 12.1 by Theodore Xu on 2023/05/08 15:51

Show last authors
1 (% class="wikigeneratedid" %)
2 This chapter provides information about advanced functions in PIStudio. **These advanced functions work only on special HMI models.**
3
4 = **Audio** =
5
6 1. Audio playing could play audio on HMI. You need to configure the relevant information, triggered by the condition, broadcast the set the mp3 audio file. The audio file can only be stored in the flash mp3 file.
7 1. Only the 9000 Series HMIs with audio modules can use this feature, and an external 3.5mm headphone head is required.
8
9 == Configuration ==
10
11 In PIStudio software, the setting procedue is as follow.
12
13 (% style="text-align:center" %)
14 [[image:音频 1.png||height="655" width="528" class="img-thumbnail"]]
15
16 **Click "Set" to open "Audio settings" window.**
17
18 (% style="text-align:center" %)
19 [[image:11.Advanced Function_html_949272a66c003cd.png||height="402" width="588" class="img-thumbnail"]]
20
21 * Audio list: Display the audio files you added. Double click the audio to configure it.
22 * Add: Add a new audio file.
23 * Delete: Delete selected audio file.
24 * Audio set: Set the configurations of the audio, contolled by address.
25
26 **Trigger configuration for audio files**
27
28 (% style="text-align:center" %)
29 [[image:音频 2.png||class="img-thumbnail"]]
30
31 * **Audio files**
32 ** MP3 file supported only.
33 ** The audio filesize should be less than 30MB.
34 ** The suffix .mp3 is necessary. The length of name should be less than 20 (including .mp3).
35 ** Audio file needs to be saved into the folder named mp3 in HMI flash, if not, it would not play. User could use the ~[[[CopyFile>>path:#_CopyFile]]] script function to import audio files into the HMI flash.
36 * **Trigger mode settings: **There are 3 kinds trigger mode to choose. They coulf be valid at the same time.
37 ** **Play according to time interval: **Set the interval time. For example ,set 3 minutes, then it will play for each 3 minutes' interval.
38 ** **Trigger to play: **There are three bit trigger conditions: Rising edge, Falling edge and Bit change. You could trigger one condition to play the audio file.
39 ** **Play according to time: **Play the audio when the time is up.
40 * **Play settings.** Set the play times and the cycle interval when it is triggered.
41
42 **Audio file playback setting**
43
44 This function is to control the playback of audio file in the list by address. (It should be used with file list.)
45
46 (% style="text-align:center" %)
47 [[image:音频 3.png||height="429" width="620" class="img-thumbnail"]]
48
49 == Control address ==
50
51 The table below describes each bit address function (including play, pause, etc). If the audio control address is HDW120, then specific function details are as shown in the table below.
52
53 (% class="table-bordered" %)
54 |=(% scope="row" %)**Function**|=(% style="width: 177px;" %)**Address**|=(% style="width: 647px;" %)**Description**
55 |(% rowspan="7" %)Play Control|(% style="width:177px" %)HDX120.0 (0(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Play control bit: Play the audio file when this bit address is triggered
56 |(% style="width:177px" %)HDX120.1 (1(% style="font-size:10.5px" %)st(%%) bit)|(% style="width:647px" %)Pause control bit: Pause playback when this bit address is triggered, or resume playback after pause
57 |(% style="width:177px" %)HDX120.2 (2(% style="font-size:10.5px" %)nd(%%) bit)|(% style="width:647px" %)Stop control bit: Stop the play when this bit address is triggered
58 |(% style="width:177px" %)HDX120.3 (3(% style="font-size:10.5px" %)rd(%%) bit)|(% style="width:647px" %)Last audio: Play last audio when this bit address is triggered.
59 |(% style="width:177px" %)HDX120.4 (4(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Next audio: Play next audio when this bit address is triggered.
60 |(% style="width:177px" %)HDX120.5 (5(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Volume increase(not supported yet), increase by 10
61 |(% style="width:177px" %)HDX120.6 (6(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Volume decrease(not supported yet), decrease by 10
62 |(% rowspan="4" %)Mode Selection|(% style="width:177px" %)HDX120.7 (7(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)once: Only play current audio file only one time
63 |(% style="width:177px" %)HDX120.8 (8(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Single cycle: Repeat playing current audio file
64 |(% style="width:177px" %)HDX120.9 (9(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Order: Play audio file orderly and stop as soon as the tas finished
65 |(% style="width:177px" %)HDX120.10 (10(% style="font-size:10.5px" %)th(%%) bit)|(% style="width:647px" %)Repeat in order: Repeat to play the audio file of the list
66
67 == State address ==
68
69 The audio play status address occupies a continuous 35 word addresses. If audio play status address is set as HDW200, the specific function allocation details are shown as below table
70
71 (% class="table-bordered" %)
72 |=(% scope="row" style="width: 183px;" %)**Address**|=(% style="width: 314px;" %)**Function**|=(% style="width: 592px;" %)**Description**
73 |=(% style="width: 183px;" %)HDW200|(% style="width:314px" %)Playback status storage address|(% style="width:592px" %)(((
74 ~=0 : stop play
75
76 ~=1 : playing
77
78 ~=2 : pause play
79 )))
80 |=(% style="width: 183px;" %)HDW201|(% style="width:314px" %)Volume value storage address|(% style="width:592px" %)Range from 0 to 100(default value is 100, and it is not adjustable so fars
81 |=(% style="width: 183px;" %)HDW202~~HDW234|(% style="width:314px" %)Audio file name|(% style="width:592px" %)Displays the file name of the audio currently playing
82
83 ✎**Note:**
84
85 * The audio file needs to be stored in the flash of PI9000 series HMI.
86 * Only PI9000 series HMI with audio module could support this function, and an external 3.5mm headphone is required.
87
88 = **Video** =
89
90 **Introduction**
91
92 1. Configure related information and play video files through conditional trigger.
93 1. Only HMI 9000 and 8150ig series support this function.
94 1. Video playing could play video on HMI project screen.
95 1. It requires "Customized Object" and "File List" objects.
96 1. Currently, the video format support by Wecon HMI are including ASF, AVI, MKV, MP4, RM, and FLV.
97
98 == Configuration ==
99
100 **Custom object configuration**
101
102 (% style="text-align:center" %)
103 [[image:视频功能部件配置.png]]
104
105 **Basic**
106
107 The function address doesn't have to be configured. DLL file name needs to be "Custom_MoviePlayer".
108
109 **Custom Address**
110
111 * ID1 is the address for storing the video file name (including the suffix). It could not be empty and the length is 32 words.
112 * ID2 is the address for video control, and occupies 1 word. It could not be empty. Please refer to[[ "Video control address">>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HControladdress-1]].
113 * ID3 is the address of video status, and occupies 1 word. It could not be empty. 0 indicate stop, and 1 indicates play.
114 * ID4 is the address for stroring the volume of video file, and occupies 1 word. 8150ig can not adjust the volume, only 9000 series can be set.
115 * ID5 is the address for the video file path, and occupies 1 word. It could not be empty. Please refer to [["Video file path">>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HFilepath]].
116
117 == Control address ==
118
119 (% class="table-bordered" %)
120 |=(% style="width: 151px;" %)**Function**|=(% colspan="2" style="width: 200px;" %)**Address**|=(% style="width: 599px;" %)**Description**
121 |(% rowspan="7" style="width:151px" %)Play Control|(% style="width:92px" %)0(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.0|(% style="width:599px" %)(((
122 Bit for playing control:This address save the name of the video file to be played.
123 )))
124 |(% style="width:92px" %)1(% style="font-size:10.5px" %)st(%%) bit|(% style="width:107px" %)HDX100.1|(% style="width:599px" %)Bit for pause control:Pause playing when this bit address is triggered, or resume playing after pause
125 |(% style="width:92px" %)2(% style="font-size:10.5px" %)nd(%%) bit|(% style="width:107px" %)HDX100.2|(% style="width:599px" %)Bit for full screen control: Maximize the video when this bit address is triggered
126 |(% style="width:92px" %)3(% style="font-size:10.5px" %)rd(%%) bit|(% style="width:107px" %)HDX100.3|(% style="width:599px" %)Last video: Play the last video when this bit address is triggered.
127 |(% style="width:92px" %)4(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.4|(% style="width:599px" %)Next video: Play the next video when this bit address is triggered.
128 |(% style="width:92px" %)5(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.5|(% style="width:599px" %)Volume increase: Increased by 10 (only be supported 9000 series)
129 |(% style="width:92px" %)6(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.6|(% style="width:599px" %)Volume decrease: Decreased by 10 (only be supported 9000 series)
130 |(% rowspan="4" style="width:151px" %)Mode Selection|(% style="width:92px" %)7(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.7|(% style="width:599px" %)Once: Only play current video file once
131 |(% style="width:92px" %)8(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.8|(% style="width:599px" %)Single cycle: Repeat to play current video file
132 |(% style="width:92px" %)9(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.9|(% style="width:599px" %)Order: Play video file of the list and stop after done
133 |(% style="width:92px" %)10(% style="font-size:10.5px" %)th(%%) bit|(% style="width:107px" %)HDX100.10|(% style="width:599px" %)Repeat in order: Repeat to play the video file of the list
134
135 == (% style="color:inherit; font-family:inherit; font-size:23px" %)File path(%%) ==
136
137 (% class="table-bordered" %)
138 |=**Value**|=**Video File Path**|=**Description**
139 |0|USB flash disk|Please create a folder named mp4 in the U disk directory to store the video files to be played
140 |1|SD card|Please create a folder named mp4 in the SD card directory to store the video files to be played
141 |2|HMI flash|Copy the video files to the mp4 folder in the directory of flash
142
143 == Case ==
144
145 Operating Procedures of File List Object Settings
146
147 (% style="text-align:center" %)
148 [[image:file setting.png]]
149
150 Configure the customized object as the above picture
151
152 Configure the file list object as below:
153
154 1. Select the directory as the MP4 folder in USB flash disk. Set the file name address as HDW150
155 1. Add the video controlling address, refer to the above video controlling address table.
156 1. Compile the project and download it to HMI, trigger the bit address to play the video from the list.
157
158 == Demo ==
159
160 **PI8150ig Video Display: **[[Download link>>https://docs.we-con.com.cn/bin/view/PIStudio/2%20Demo/Applications/#H7PI8150igVideoDisplay]]
161
162 = **Email** =
163
164 Wecon HMI can send email with information from fields to the specified email address as soon as the conditions is triggered, but email sending is based on the network.
165
166 == Email setting ==
167
168 In "PIStudio" software, click "Project" → "E-mail" to open email function setting screen.
169
170 (% style="text-align:center" %)
171 [[image:邮件 1.png||height="780" width="597" class="img-thumbnail"]]
172
173 **SMTP Settings**
174
175 * **Sender Name: **Fill the sender's name, which is composed of Chinese characters, letters (case sensitive) and numbers. But it can not contain the following special English symbols:  ',', ';', '"', '<'. Maximum character length 32 is allowed.
176 * **Password:** Fill in the password or authorization code of the mailbox. If the server needs to set the authorization code, the authorization code needs to be used. If the authorization code is not used, the password is used. Please refer to the SMTP service in the mailbox for the authorization code information. It cases sensitive, maximum character length 32 allowed in password.
177 * **Confirm Password: **Confirm the password or authorization code of the mailbox.
178 * **Email Address: **Fill in the sender's email address, case sensitive, maximum character length 32 allowed in it.Such as [[support@we-con.com.cn>>path:mailto:support@we-con.com.cn]].
179 * **SMTP Server: **Please refer to the mailbox account settings. If you enter a common mailbox, the corresponding server address will be automatically written. such as smtp.exmail.qq.com.
180
181 (% class="table-bordered" %)
182 |=Email|=Email server|=Port number
183 |163 email|smtp.163.com|465
184 |126 email|smtp.126.com|465
185 |QQ email|smtp.qq.com|465
186 |Sina email|smtp.sina.com|465
187 |Sohu email|smtp.sohu.com|465
188 |Yahoo email|smtp.mail.yahoo.com.cn|465
189 |Google email|smtp.gmail.com|465
190
191 **✎Note:** Gmail also needs to enable the [allow unsafe apps] option in the account, otherwise the mail will not be sent normally.
192
193 (% style="list-style-type:disc" %)
194 * **Encryption Type: **SSL is a security protocol that provides security and data integrity for network communications. It encrypts network connections at the transport layer; TLS (STARTTLS) upgrades connections to SSL instead of using a separate encrypted communication port.
195 * **The Port Number: **Enter corresponding port number according to the SMTP serve addrress entered. You could only enter interger between 1 and 65535. Do not enter more than 6 digits in length. Common port numbers are port 25, 465 and 587.
196 ** Port 25: It does not protect the original data when transmitting data. The data can be seen. Generally, port 25 must be selected as no encryption or TLS(STARTTLS) encryption mode to send data correctly.
197 ** Port 465: It protect the original data when transmitting data. The data can not be seen. Generally, port 465 must be selected as SSL encryption mode to send data correctly.
198 ** Port 587: The original data is protected only after the TLS(STARTTLS) command is executed. Generally, port 587 must be selected as TLS(STARTTLS) encryption mode to send data correctly.
199
200 **✎Note: **Port 25 is open to SMTP servers, mainly for sending mail. But the port has vulnerability. Hackers often use port 25 to find SMTP servers to forward spam.
201
202 * **Error Message**
203 ** Set the error message receiving address, you could use the information to get the reasons of errors.
204 ** The error types in the mail function are divided into two types: custom rule error and server's error.
205 ** Custom rule errors are as follows.
206
207 (% class="table-bordered" %)
208 |**Message**
209 |Email settings are incorrect
210 |Email account is incorrect
211 |Email password could not include blank
212 |the settings of SMTP server are incorrect
213 |The range of SMTP server ports number should be integer, which is between 1 and 65535.
214 |The type of encryption for SMTP is incorrect
215 |The name of sender or email address setting is incorrect.
216 |The names of Recipients or email address setting are incorrect.
217 |The names of CC recipients or email address setting are incorrect.
218 |The names of Secret delivery recipients or email address setting are incorrect.
219 |Email topic could not be blank
220 |Email content could not be blank
221 |Total size of attachments should be below 25M
222 |Attachment "xxxx" is nonexistent
223
224 Server's errors are as follows.
225
226 (% class="table-bordered" %)
227 |**Message**
228 |smtp-server: 554 DT: SPM
229 |smtp-server: 550 RP: TRC
230 |smtp-server: 550 Limitation of connecting counts
231 |smtp-server: 535
232 |smtp-server: 550 Error: Content rejected
233 |smtp-server: 451 Internal server error
234 |smtp-server: 535 Invalid login user or password
235 |smtp-server: 550 too many sending requests today
236 |smtp-server: 452 Too many recipients received this hour.
237 |smtp-server: 535 Error: Authentication failed, system busy
238 |could not connect: Connection timed out
239 |Unexpected EOF on SMTP connection
240 |could not initiate SSL/TLS connection
241 |smtp-server: 530 Need to issue a STARTTLS command first.
242 |could not resolve host
243 |could not connect: Connection timed out
244 |could not connect: Connection refused
245 |smtp-server: 550 User not found: aaa.163.com
246
247 * **Manual Trigger**
248
249 It is for modifying the email sending settings when HMI is running. According to the set manual trigger address, the address is offset backward to get the address of the corresponding function (a total of 201 words). Take HDW100 as an example.
250
251 (% class="table-bordered" %)
252 |(% style="width:201px" %)**Address**|(% style="width:586px" %)**Description**
253 |(% style="width:201px" %)HDX100.0|(% style="width:586px" %)Sending trigger
254 |(% style="width:201px" %)HDX101.0 to HDX101.15|(% style="width:586px" %)It is used for triggering recipient groups, for example, HDW101.0 set ON, and the address in group 1 will be in recipient list.
255 |(% style="width:201px" %)HDX103.0 to HDX103.15|(% style="width:586px" %)It is used for triggering recipient groups, for example, HDW103.0 set ON, and the address in group 1 will be in CC list.
256 |(% style="width:201px" %)HDX105.0 to HDX105.15|(% style="width:586px" %)It is used for triggering recipient groups, for example, HDW105.0 set ON, and the address in group 1 will be in BCC list (Secret delivery).
257 |(% style="width:201px" %)HDW107 to HDW171|(% style="width:586px" %)The subject length is limited to 64 words. (If it exceeds, it will intercept 64 words of content)
258 |(% style="width:201px" %)HDW172 to HDW300|(% style="width:586px" %)The content length is limited to 128 words. (If it exceeds, it will intercept 128 words of content)
259 |(% style="width:201px" %)HDX301.0|(% style="width:586px" %)Whether to send an alarm record attachment (a file named AlarmDataFile.db)
260
261 1. Emails that sent manually are not queued. Emails trigger by bit change, rising edge, falling edge and timing need to be sent in the sequence of triggering. The maximum value is 100, and those who are added after it is exceeded will be discarded. If an email is sending, it would send immediately after the current email is sent. If there is no email sending, it would send immediately.
262 1. If the trigger condition sent manually is the rising edge trigger, before the mail is sent, no new mail will be sent even if it is triggered again. No matter the email is sent successfully or not, the corresponding trigger would be OFF.
263 1. Emails that sent manually would only be sent once no matter the sending error is custom error, network or other errors.
264
265 == Email sending settings ==
266
267 (% style="text-align:center" %)
268 [[image:邮件 2.png||class="img-thumbnail"]]
269
270 1. **Add. **A maximum of 1024 email can be added.
271 1. **Modify.** Select an email to modify the content and configuration.
272 1. **Delete. **You could select an email to delete or click the "ID" column to delete in batch.
273
274 (% style="text-align:center" %)
275 [[image:邮件 3.png||height="578" width="744" class="img-thumbnail"]]
276
277 **Email sending configuration.**
278
279 * **Theme. **The value cannot be empty and case sensitive. The total length  cannot exceed 256 characters.
280 * **Content of email. **The contents are divided into three combinations: text, alarm and variable. The list can contain only 32 items at most, and the total length of the preview cannot exceed 1024 items.
281 ** **Text. **You could directly edit the text of language 1 to language 3. If you need to set multiple languages, click "edit all text" to set. You may also select "Text library". The content is case sensitive, and the total length of English/Chinese characters/numbers/symbols does not exceed 253.
282 ** **Alarm. **You could select "bit alarm" or "word alarm" from the list. The content is from alarm text. if the alarm changes, the content changes with it. The content is case sensitive, and the total length of English/Chinese characters/numbers/symbols does not exceed 253.
283 ** **Variable. **Set the corresponding variable address. Read value or strings according to the specified format, and the read information will be displayed in the corresponding position in the mail content.
284 * **Preview. **Combine the content of current edited email and diaplay it for you to modify the content conviniently. The preview length cannot exceed 1024.
285 * **Sending method. **It is divided into timed send interval and bit address trigger tranmission. The two methods cannot be used at the same time.
286 ** timed send interval. After booting, the current system time is used to start calculating, and each time the time  is up, the information will be sent to the set recipient in the form of an email, and the minimum time should be set to 5 minutes. **Note: **The first boot is not sent.
287 ** Bit address trigger tranmission. When the set trigger address meets the trigger conditon, the information will be sent to the set recipient in the form of an email. If the content select alarm, the alarm address would be written in the trigger address. There are three methods to trigger: sending on rising edge, sending on falling edge and send when the bit changes.
288 * **Recipient.** It is set in groups. You could send  multiple groups, and each group can have multiple recipients.
289 * **Add CC.** Sends the current email to other recipients.
290 * **Add secret delivery. ** Sends the current email to other recipients, but the recipient and cc recipients do not see the BCC recipient.
291 * when sending an email, you must set a recipient. CC recipients and BCC recipients are not to be set. The total number of recipinet, CC recipients and BCC recipients is 40.
292 * **Recipient priority. **Set the priority order of recipients to recipient, BCC, and CC.
293
294 **✎Note: **If the recipient address you select exists in all three positions, it exist only in the highest priority position. For example, if the recipient of an email has aaa, the bcc has aaa, and the cc has aaa, then let aaa only be the recipient.
295
296 == Recipient group setting ==
297
298 (% style="text-align:center" %)
299 [[image:邮件 4.png||class="img-thumbnail"]]
300
301 1. **All Group.** The groups you added.
302 1. **Group to send. **The groups that you send the emails to.
303 1. **Open recipinet settings.** Set the information of recipients, and add and subtract groups.
304
305 == Recipient setting ==
306
307 (% style="text-align:center" %)
308 [[image:邮件 5.png||class="img-thumbnail"]]
309
310 1. **Add. **Add a recipient. There are non-dynamic recipient and dynamic recipient. They cannot be used at the same time. You may just fill in the  recipient's name and email address. The dynamic recipient address  is limited to 32 characters, and a maximum of 40 recipients can be added.
311
312 (% style="text-align:center" %)
313 [[image:邮件 6.png||class="img-thumbnail"]]
314
315 (% start="2" style="list-style-type:decimal" %)
316 1. **Modify. **Select one recipient and click "modify" or double click the recipient to modify. If it is non-dynamic recipient, you could modify the name and email address. The email is unique. If it is dynamic recipient, you could modify the address, and the address is unique.
317 1. **Delete.** Select one recipient or multiple recipents to delete, or click the ID column to select all.
318 1. **Nuber of group. **You could click the  up/down arrow to increase or devrease groups. The default number is 1. The maximum number is 16.
319 1. **Description. **To decribe the group information. The total length shall not exceed 32.
320
321 == Test sending settings ==
322
323 (% style="text-align:center" %)
324 [[image:邮件 7.png||class="img-thumbnail"]]
325
326 (% class="wikigeneratedid" %)
327 **✎Note: **
328
329 1. You can open this after the SMTP server is set.
330 1. When NetEase mail (126, 163 and yeah) occurs erros 554, it may be that the mailbox used is restricted by the anti-spam mechanism, and the performance may be that it cannot send emails in bulk or directly.
331 1. When TOM mail is sender's mail, the name of it and the recipient tested must be English, otherwise the email would be returned.
332 1. When testing with Zoho mailbox, there was a delay of less than 3 minutes.
333 1. The custom errors for the test error is as follows.
334
335 (% class="table-bordered" %)
336 |=(% style="width: 129px;" %)Error code|=(% style="width: 946px;" %)Cause of reason
337 |(% style="width:129px" %)0|(% style="width:946px" %)CSMTP_NO_ERROR
338 |(% style="width:129px" %)100|(% style="width:946px" %)WSA_STARTUP = Unable to initialize winsock2
339 |(% style="width:129px" %)101|(% style="width:946px" %)WSA_VER = Wrong version of the winsock2
340 |(% style="width:129px" %)102|(% style="width:946px" %)WSA_SEND = Function send() failed
341 |(% style="width:129px" %)103|(% style="width:946px" %)WSA_RECV = Function recv() failed
342 |(% style="width:129px" %)104|(% style="width:946px" %)WSA_CONNECT = Function connect failed
343 |(% style="width:129px" %)105|(% style="width:946px" %)WSA_GETHOSTBY_NAME_ADDR = Unable to determine remote server
344 |(% style="width:129px" %)106|(% style="width:946px" %)WSA_INVALID_SOCKET = Invalid winsock2 socket
345 |(% style="width:129px" %)107|(% style="width:946px" %)WSA_HOSTNAME = Function hostname() failed
346 |(% style="width:129px" %)108|(% style="width:946px" %)WSA_IOCTLSOCKET = Function ioctlsocket() failed
347 |(% style="width:129px" %)109|(% style="width:946px" %)WSA_SELECT
348 |(% style="width:129px" %)110|(% style="width:946px" %)BAD_IPV4_ADDR = Improper IPv4 address
349 |(% style="width:129px" %)200|(% style="width:946px" %)UNDEF_MSG_HEADER = Undefined message header
350 |(% style="width:129px" %)201|(% style="width:946px" %)UNDEF_MAIL_FROM = Undefined mail sender
351 |(% style="width:129px" %)202|(% style="width:946px" %)UNDEF_SUBJECT = Undefined message subject
352 |(% style="width:129px" %)203|(% style="width:946px" %)UNDEF_RECIPIENTS = Undefined recipient
353 |(% style="width:129px" %)204|(% style="width:946px" %)UNDEF_RECIPIENT_MAIL = Undefined mail recipent
354 |(% style="width:129px" %)205|(% style="width:946px" %)UNDEF_LOGIN = Undefined user login
355 |(% style="width:129px" %)206|(% style="width:946px" %)UNDEF_PASSWORD = Undefined user password
356 |(% style="width:129px" %)207|(% style="width:946px" %)BAD_LOGIN_PASSWORD = Invalid user login or password
357 |(% style="width:129px" %)208|(% style="width:946px" %)BAD_DIGEST_RESPONSE = Server returned a bad digest MD5 response
358 |(% style="width:129px" %)209|(% style="width:946px" %)BAD_SERVER_NAME = Unable to determine server name for digest MD5 response
359 |(% style="width:129px" %)300|(% style="width:946px" %)COMMAND_MAIL_FROM = Server returned error after sending MAIL FROM
360 |(% style="width:129px" %)301|(% style="width:946px" %)COMMAND_EHLO = Server returned error after sending EHLO
361 |(% style="width:129px" %)302|(% style="width:946px" %)COMMAND_AUTH_PLAIN = Server returned error after sending AUTH PLAIN
362 |(% style="width:129px" %)303|(% style="width:946px" %)COMMAND_AUTH_LOGIN = Server returned error after sending AUTH LOGIN
363 |(% style="width:129px" %)304|(% style="width:946px" %)COMMAND_AUTH_CRAMMD5 = Server returned error after sending AUTH CRAM-MD5
364 |(% style="width:129px" %)305|(% style="width:946px" %)COMMAND_AUTH_DIGESTMD5 = Server returned error after sending AUTH DIGEST-MD5
365 |(% style="width:129px" %)306|(% style="width:946px" %)COMMAND_DIGESTMD5 = Server returned error after sending MD5 DIGEST
366 |(% style="width:129px" %)307|(% style="width:946px" %)COMMAND_DATA = Server returned error after sending DATA
367 |(% style="width:129px" %)308|(% style="width:946px" %)COMMAND_QUIT = Server returned error after sending QUIT
368 |(% style="width:129px" %)309|(% style="width:946px" %)COMMAND_RCPT_TO = Server returned error after sending RCPT TO
369 |(% style="width:129px" %)310|(% style="width:946px" %)MSG_BODY_ERROR = Error in message body (邮件正文中出现错误)
370 |(% style="width:129px" %)400|(% style="width:946px" %)CONNECTION_CLOSED = Server has closed the connection
371 |(% style="width:129px" %)401|(% style="width:946px" %)SERVER_NOT_READY = Server is not ready
372 |(% style="width:129px" %)402|(% style="width:946px" %)SERVER_NOT_RESPONDING = Server not responding
373 |(% style="width:129px" %)403|(% style="width:946px" %)SELECT_TIMEOUT
374 |(% style="width:129px" %)404|(% style="width:946px" %)FILE_NOT_EXIST = File not exist
375 |(% style="width:129px" %)405|(% style="width:946px" %)MSG_TOO_BIG = Message is too big
376 |(% style="width:129px" %)406|(% style="width:946px" %)BAD_LOGIN_PASS = Bad login or password
377 |(% style="width:129px" %)407|(% style="width:946px" %)UNDEF_XYZ_RESPONSE = Undefined xyz SMTP response
378 |(% style="width:129px" %)408|(% style="width:946px" %)LACK_OF_MEMORY = Lack of memory
379 |(% style="width:129px" %)409|(% style="width:946px" %)TIME_ERROR = time() error
380 |(% style="width:129px" %)410|(% style="width:946px" %)RECVBUF_IS_EMPTY = RecvBuf is empty
381 |(% style="width:129px" %)411|(% style="width:946px" %)SENDBUF_IS_EMPTY = SendBuf is empty
382 |(% style="width:129px" %)412|(% style="width:946px" %)OUT_OF_MSG_RANGE = Specified line number is out of message size
383 |(% style="width:129px" %)413|(% style="width:946px" %)COMMAND_EHLO_STARTTLS = Server returned error after sending STARTTLS
384 |(% style="width:129px" %)414|(% style="width:946px" %)SSL_PROBLEM = SSL problem
385 |(% style="width:129px" %)415|(% style="width:946px" %)SSL_PROBLEM = SSL problem
386 |(% style="width:129px" %)416|(% style="width:946px" %)STARTTLS_NOT_SUPPORTED = The STARTTLS command is not supported by the server
387 |(% style="width:129px" %)417|(% style="width:946px" %)LOGIN_NOT_SUPPORTED = AUTH LOGIN is not supported by the server
388
389 == Email status ==
390
391 **Network disconnection error**
392
393 If the fault is determined as a network disconnection error, the system does not delete the sent information and does not record the number of errors, and it would make an infinite send attempt.
394
395 **Custom rule error**
396
397 If the fault is determined as a custom rule error, delete the information.
398
399 **Server return error**
400
401 If the fault is determined as a server return error, then the error time add 1. It would try to send the email for 3 times. Regardless of whether the transmission is successful or not, it would delete the email to be sent. The test results are as follows.
402
403 (% class="table-bordered" %)
404 |=(% style="width: 125px;" %)**Server name**|=(% style="width: 186px;" %)**The number of sent**|=(% style="width: 765px;" %)**Consequences of exceeding the limit**
405 |(% style="width:125px" %)126|(% style="width:186px" %)160|(% style="width:765px" %)No more delivery on that day
406 |(% style="width:125px" %)163|(% style="width:186px" %)160|(% style="width:765px" %)No more delivery on that day
407 |(% style="width:125px" %)we-con|(% style="width:186px" %)800|(% style="width:765px" %)No more delivery on that day
408 |(% style="width:125px" %)qq|(% style="width:186px" %)50|(% style="width:765px" %)It can be sent again after a few minutes or a few hours
409 |(% style="width:125px" %)sohu|(% style="width:186px" %)160|(% style="width:765px" %)No more delivery on that day
410 |(% style="width:125px" %)sina|(% style="width:186px" %)50|(% style="width:765px" %)It can be sent again after a few minutes or a few hours, but cannont be received normally
411 |(% style="width:125px" %)gmail|(% style="width:186px" %)500|(% style="width:765px" %)No more delivery on that day
412
413 **Message Prompt**
414
415 1. If the email to be sent is deleted, a message will pop up.
416 1. If the email is sent successfully, a messge will pop up: "The email is sent successfully."
417 1. If the five symbols ',' , ' | ', '<', '>' and '&' appear in the fields set by the message prompt, the message prompt will display an abnormal message.
418
419 **Mail attachment**
420
421 Currently, the email attachment function only supports sending the specified alarm record (AlarmDataFile.db file), and does not support selecting content to send.
422
423 = USB keyboard =
424
425 (% class="wikigeneratedid" id="HIntroduction" %)
426 **Introduction**
427
428 1. HMI support keyboard via USB port of HMI.
429 1. When the keyboard function is enabled, the "Cursor Display" function is enabled by default. The user could move the cursor through the "up, down, left and right buttons" of the keyboard, and then press the Enter key to select the object.
430 1. Multiple devices could be connected with HMI via USB HUB (up to 4 external devices), such as: mouse, keyboard, scanner, magnetic stripe reader, etc.
431
432 == Enable function ==
433
434 In the software PIStudio, Click "Project" → "Project settings" → "Extend", and check "Enable keyboard" in "Input device" settings area as below.
435
436 (% style="text-align:center" %)
437 [[image:11.Advanced Function_html_f6cded728eedf4ce.png||height="567" width="501" class="img-thumbnail"]]
438
439 == Configuration decription ==
440
441 1. When the keyboard function is enabled, the "Cursor Display" function is enabled by default. The user could move the cursor through the “up, down, left and right buttons” of the keyboard, and then press the Enter key to select the object;
442 1. NumLock: When NumLock key is not lit, the keypad number is not allowed to be input (offline simulation does not allow all numeric keys to be input, including the numeric keys on the left side of the keyboard);
443 1. Key combination: (1) "Shift" + the left side of the keyboard and the special symbol button, to achieve special character input, such as: ~~ ! @ # $ % ^ & * ( ) _ + { } : "<> ? ;
444 1. Use the system special addresses "HSW1073 and HSW1074" to write custom key combinations in the script (currently only two key combinations are supported);
445 1. Caps Lock: In lowercase mode, shift+ letters, to enter uppercase; in uppercase mode, shift+ letters enter lowercase;
446
447 == **System special address** ==
448
449 In practical application, the [Enable Keyboard] function could be combined with the related "system special address" to achieve multi-key combination operation.
450
451 (% class="table-bordered" %)
452 |=(% style="width: 114px;" %)**Address**|=(% style="width: 229px;" %)**Description**|=(% style="width: 733px;" %)**Function**
453 |(% style="width:114px" %)HSW1073|(% style="width:229px" %)Keyboard key value|(% style="width:733px" %)(((
454 The currently pressed key value is displayed. The key value is shown in Table 1
455
456 (The Numeric/Character display object is not updated when it is being entered)
457 )))
458 |(% style="width:114px" %)HSW1074|(% style="width:229px" %)Keyboard key status|(% style="width:733px" %)(((
459 Display current key states
460
461 ~=0: key release
462
463 ~=1: key press
464
465 ~=2: Press and hold long
466
467 (The Numeric/Character display object is not updated when it is being entered)
468 )))
469 |(% style="width:114px" %)HSW1075|(% style="width:229px" %)Cursor speed|(% style="width:733px" %)Control the movement speed of the cursor, the range is 0~~100, the default is 20
470 |(% style="width:114px" %)HSW1076|(% style="width:229px" %)X coordinate value of cursor|(% style="width:733px" %)The X value of the current position of the cursor, range: 0~~screen width-1
471 |(% style="width:114px" %)HSW1077|(% style="width:229px" %)Y coordinate value of cursor|(% style="width:733px" %)The Y value of the current position of the cursor, range: 0~~screen height-1
472 |(% style="width:114px" %)HSW1078|(% style="width:229px" %)The ASCII code of keyboard key|(% style="width:733px" %)(((
473 Only the ASCII values of letters, numbers, and symbols are displayed. The ASCII value of the function keys is not displayed, as shown in Table 2
474
475 (The Numeric/Character display object is not updated when it is being entered)
476 )))
477 |(% style="width:114px" %)HSW1079|(% style="width:229px" %)Enable cursor position and Enter key mode|(% style="width:733px" %)(((
478 HSX1079.0 = 1: Set the cursor position according to HSW1076 and HSW1077 value;
479
480 HSX1079.1 = 0: When Numeric/Character display object is entered, enter key is for end input instruction. When no Numeric/Character display object is entered, enter key is for normal click;
481
482 HSX1079.1 = 1: Enter key only for normal click, not for keyboard end input instruction;
483 )))
484
485 **Key-Value Appendix Table (Decimal) (104Keys)**
486
487 (% class="table-bordered" %)
488 |=**Key**|=**Value**|=**Key**|=**Value**|=**Key**|=**Value**
489 |ESC|1|i I|23|Alt (Right)|100
490 |F1|59|o O|24|windows(Right)|126
491 |F2|60|p P|25|Menu|127
492 |F3|61|[ {|26|Right_ctrl|97
493 |F4|62|] }|27|Print Screen|99
494 |F5|63|Enter|28|ScrollLock|70
495 |F6|64|CapsLock|58|PauseBreak|119
496 |F7|65|a A|30|Insert|110
497 |F8|66|s S|31|Home|102
498 |F9|67|d D|32|PageUp|104
499 |F10|68|f F|33|Delete|111
500 |F11|87|g G|34|End|107
501 |F12|88|h H|35|PageDown|109
502 |` ~~|41|j J|36|↑|103
503 |1 !|2|k K|37|↓|108
504 |2 @|3|l L|38|←|105
505 |3 #|4|; :|39|→|106
506 |4 $|5|' "|40|NumLock (Keypad)|69
507 |5%|6|\ ~||43|/ (Keypad)|98
508 |6 ^|7|Shift (Left)|42|* (Keypad)|55
509 |7 &|8|z Z|44|- (Keypad)|74
510 |8 *|9|x X|45|+ (Keypad)|78
511 |9 (|10|c C|46|Enter (Keypad)|96
512 |0 )|11|v V|47|. (Keypad)|83
513 |- _|12|b B|48|0 (Keypad)|82
514 |+ =|13|n N|49|1 (Keypad)|79
515 |Backspace|14|m M|50|2 (Keypad)|80
516 |Tab|15|, <|51|3 (Keypad)|81
517 |q Q|16|. >|52|4 (Keypad)|75
518 |w W|17|/ ?|53|5 (Keypad)|76
519 |e E|18|Shift (Right)|54 |6 (Keypad)|77
520 |r R|19|Ctrl (Left)|29|7 (Keypad)|71
521 |t T|20|Windows(Left)|125|8 (Keypad)|72
522 |Y y|21|Alt (Left)|56|9 (Keypad)|73
523 |u U|22|space|57| |
524
525 **ASCII Code**
526
527 (% class="table-bordered" %)
528 |**Code**|**Value**|**Code**|**Value**|**Code**|**Value**|**Code**|**Value**
529 |32|space|56|8|80|P|104|h
530 |33|!|57|9|81|Q|105|i
531 |34|"|58|:|82|R|106|j
532 |35|#|59|;|83|S|107|k
533 |36|$|60|<|84|T|108|l
534 |37| %|61|= |85|U|109|m
535 |38|&|62|>|86|V|110|n
536 |39|'|63|?|87|W|111|o
537 |40|(|64|@|88|X|112|p
538 |41|)|65|A|89|Y|113|q
539 |42|*|66|B|90|Z|114|r
540 |43|+|67|C|91|[|115|s
541 |44|,|68|D|92|\|116|t
542 |45|-|69|E|93|]|117|u
543 |46|.|70|F|94|^|118|v
544 |47|/|71|G|95|_|119|w
545 |48|0|72|H|96|`|120|x
546 |49|1|73|I|97|a|121|y
547 |50|2|74|J|98|b|122|z
548 |51|3|75|K|99|c|123|{
549 |52|4|76|L|100|d|124|~|
550 |53|5|77|M|101|e|125|}
551 |54|6|78|N|102|f|126|~~
552 |55|7|79|O|103|g| |
553
554 == **Scripts example** ==
555
556 'HSW1073 key value
557
558 'HSW1074 key states
559
560 * 0: released;
561 * 1: pressed;
562 * 2: Holding pressed
563
564 'HSW1078 ASCII value of key
565
566 **Example 1**
567
568 {{code language="lua"}}
569 if @W_HSW1073 = 29 then                                            'Ctrl key value is 29
570
571     if @W_HSW1074 = 1 or @W_HSW1074 = 2               'Press Ctrl key
572
573               @W_HDW1000 = 1
574
575     else                                                                               'Release Ctrl key
576
577               @W_HDW1000 = 0
578
579     endif
580
581 endif
582 {{/code}}
583
584 **Example 2**
585
586 {{code language="lua"}}
587 if @W_HSW1073 = 59 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then              'F1 key value is 59
588
589    if @W_HDW1000 = 1 then                                                                                          'Combination Ctrl + F1
590
591          @W_HDW2000 = @W_HDW2000 + 1                                                                  'Function of combination key is HDW2000 + 1
592
593     endif
594
595 endif
596 {{/code}}
597
598 **Example 3**
599
600 {{code language="lua"}}
601 if @W_HSW1073 = 60 and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then              'the value of F2 is 60
602
603    if @W_HDW1000 = 1 then                                                                                          'Combination Ctrl + F2
604
605             @W_HDW2000 = @W_HDW2000 - 1                                                                'Function of combination key is HDW2000 - 1
606
607   endif
608
609 endif
610 {{/code}}
611
612 **Example 4**
613
614 {{code language="lua"}}
615 if AsString(@W_HSW1078) = "a" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then          'Page up
616
617     if @W_HSW13 > 0 then
618
619            @W_HSW13 = @W_HSW13 - 1
620
621     endif
622
623 endif
624 {{/code}}
625
626 **Example 5**
627
628 {{code language="lua"}}
629 if AsString(@W_HSW1078) = "b" and (@W_HSW1074 = 1 or @W_HSW1074 = 2) then          'Page down
630
631     @W_HSW13 = @W_HSW13 + 1
632
633      if @W_HSW13 > 3 then
634
635               @W_HSW13 = 3
636
637      endif
638
639 endif
640 {{/code}}
641
642 = **rtsp web camera** =
643
644 **Introduction**
645
646 1. An external IP Camera (web camera) can be used to display the screen captured by the it to achieve real-time monitoring of the scene of the equipment.
647 1. ONVIF protocol and H.264 coding camera (RTSP web camera) are supported.
648
649 **Supported Model:**
650
651 * Hikvision
652 ** DS-2CD1321D-I
653 ** DS-2CD3T20FD-I3W
654 ** DS-2CD1221D-I3
655 ** DS-2CV3Q21FD-IW
656 * Dahua
657 ** DH-IPC-HFW1025D
658 ** DH-IPC-HFW1235M-I1
659
660 1. 8000 series HMI can view only **one **IP Camera monitoring screen at a time (only **one **camera object can be placed in a project).
661 1. 8000 series HMI can view only **four** IP Camera monitoring screen at a time (only **four **camera object can be placed in a project).
662
663 == **Camera search** ==
664
665 In the software PIStudio, Click "Project" -> "Project settings"-> "Extend", and check "Enable camera search module", shown as below.
666
667 (% style="text-align:center" %)
668 [[image:rtsp摄像头 1.png||class="img-thumbnail"]]
669
670 The maximum number of searches: Configure the number of online camera.  The maximum number of searches does not exceed 20, and should be greater than that of online camera.
671
672 === **Function address** ===
673
674 To configure the information of searches anf the records of search results. There are as follows.
675
676 (% class="table-bordered" %)
677 |(% style="width:226px" %)**Address**|(% style="width:533px" %)**Description**|(% style="width:240px" %)**Length**
678 |(% style="width:226px" %)HDW200|(% style="width:533px" %)Username|(% style="width:240px" %)20 words
679 |(% style="width:226px" %)HDW220|(% style="width:533px" %)Password|(% style="width:240px" %)20 words
680 |(% style="width:226px" %)HDX240.0|(% style="width:533px" %)Falling edge trigger search|(% style="width:240px" %)1 bit
681 |(% style="width:226px" %)HDX240.1|(% style="width:533px" %)(((
682 Search status
683
684 0: The search is complete.
685
686 1: It is searching.
687 )))|(% style="width:240px" %)1 bit
688 |(% colspan="2" rowspan="1" style="width:109px" %)The first search result|(% style="width:240px" %)80 words
689 |(% style="width:226px" %)HDW241|(% style="width:533px" %)IP address|(% style="width:240px" %)16 words
690 |(% style="width:226px" %)HDW257|(% style="width:533px" %)(((
691 ~=1: correct password
692
693 ~=0: wrong password
694 )))|(% style="width:240px" %)1 word
695 |(% style="width:226px" %)HDW258|(% style="width:533px" %)Device serial number|(% style="width:240px" %)43 words
696 |(% style="width:226px" %)HDW301|(% style="width:533px" %)Camera alias|(% style="width:240px" %)20 words
697 |(% colspan="2" rowspan="1" style="width:109px" %)The second search result|(% style="width:240px" %)80 words
698 |(% style="width:226px" %)HDW321|(% style="width:533px" %)IP address|(% style="width:240px" %)16 words
699 |(% style="width:226px" %)...|(% style="width:533px" %)...|(% style="width:240px" %)...
700
701 The username and password of function address need to entered manually. When searching for cameras, the username and password will be matched first, then each camera under the account will be retrieved, and the retrieved results will be stored in the response address. If the password is correct, the corresponding serial number would be displayed.
702
703 == **Camera display** ==
704
705 Add the object "camera display" to the project, click "Enable rtsp camera", as below.
706
707 (% style="text-align:center" %)
708 [[image:rtsp摄像头 2.png]]
709
710
711 Compile and download project, please click [Search Camera] button to get camera information in LAN The username and password here need to be entered manually. During searching camera, it will try to use this username and password to log in IP camera and store the result of login. If the password is correct, the “password correct” address will be displayed as 1 and the device serial number will be displayed. If the “password correct” address is 0, the device serial number would not be displayed.
712
713 === **Function address** ===
714
715 (% class="table-bordered" %)
716 |=(% style="width: 204px;" %)**Address**|=(% colspan="2" style="width: 702px;" %)**Description**|=(% style="width: 245px;" %)**Length**
717 |(% style="width:204px" %)HAW100|(% colspan="2" style="width:702px" %)Username|(% style="width:245px" %)20 words
718 |(% style="width:204px" %)HAW120|(% colspan="2" style="width:702px" %)password|(% style="width:245px" %)20 words
719 |(% style="width:204px" %)HAW140|(% colspan="2" style="width:702px" %)Alias|(% style="width:245px" %)20 words
720 |(% style="width:204px" %)HAW160|(% colspan="2" style="width:702px" %)Device serial number|(% style="width:245px" %)43 words
721 |(% style="width:204px" %)HAW203|(% colspan="2" style="width:702px" %)Camera ID|(% style="width:245px" %)1 word
722 |(% colspan="1" rowspan="11" style="width:204px" %)HAW204|(% colspan="2" rowspan="1" style="width:702px" %)Camera Control|(% colspan="1" style="width:245px" %)1 word
723 |(% style="width:211px" %)HAX204.0|(% style="width:787px" %)Open camera|(% colspan="1" style="width:245px" %)1 word
724 |(% style="width:211px" %)HAX204.1|(% style="width:787px" %)Close camera|(% colspan="1" style="width:245px" %)1 word
725 |(% style="width:211px" %)HAX204.2|(% style="width:787px" %)Camera up|(% colspan="1" style="width:245px" %)1 word
726 |(% style="width:211px" %)HAX204.3|(% style="width:787px" %)Camera down|(% colspan="1" style="width:245px" %)1 word
727 |(% style="width:211px" %)HAX204.4|(% style="width:787px" %)Camera left|(% colspan="1" style="width:245px" %)1 word
728 |(% style="width:211px" %)HAX204.5|(% style="width:787px" %)Camera right|(% colspan="1" style="width:245px" %)1 word
729 |(% style="width:211px" %)HAX204.6|(% style="width:787px" %)screenshot|(% colspan="1" style="width:245px" %)1 word
730 |(% style="width:211px" %)HAX204.7|(% style="width:787px" %)Binding camera|(% colspan="1" style="width:245px" %)1 word
731 |(% style="width:211px" %)HAX204.8|(% style="width:787px" %)Set Alias|(% colspan="1" style="width:245px" %)1 word
732 |(% style="width:211px" %)HAX204.9|(% style="width:787px" %)Camera stop moving|(% colspan="1" style="width:245px" %)1 word
733 |(% style="width:204px" %)HAW205|(% colspan="2" style="width:702px" %)(((
734 Camera status
735
736 ~=0: camera disconnected
737
738 ~=1: camera connected
739
740 ~=2: Camera is connecting
741 )))|(% style="width:245px" %)1 word
742 |(% style="width:204px" %)HAW206|(% colspan="2" style="width:702px" %)(((
743 Screenshot save location
744
745 ~=0: Screenshot is saved into flash
746
747 ~=1: Screenshot is saved into USB disk
748
749 ~=2: Screenshot is saved into SD card
750 )))|(% style="width:245px" %)1 word
751
752 **Operating Procedures**
753
754 Fill the camera ID address with the camera serial number searched by the camera search module, and trigger the binding address to fill username and password.
755
756 * If the camera searching is disabled, then users need to manually enter the information of this camera, including username, password, and device serial number. Device serial number could be obtained by checking the label of camera.
757
758 (% style="text-align:center" %)
759 [[image:11.Advanced Function_html_9ba06415a43f4264.png||height="232" width="412" class="img-thumbnail"]]
760
761 * If the IP CAMERA was triggered successfully, we could see the monitor screen and we could also set a alias for the camera and control the movement of the camera(up, down, left and right, some IP camera could not support the movement) or the screenshot. These operations could not be performed if camera off.
762
763 (% style="text-align:center" %)
764 [[image:11.Advanced Function_html_5e0967606b906db1.jpg||height="250" width="333" class="img-thumbnail"]]
765
766
767 **✎Note:**
768
769 * Camera configuration. When you get the camera, you need to activate the camera and enable the onvif protocol for the camera according to the user manual and tools provided by the camera manufacturer. If the configuration is not correct, the camera cannot be used on the HMI.
770 * When reading camera information, you need to configure the user name and password for the camera. When multiple cameras are enabled, you are advised to set the user names and passwords of all cameras to be the same.
771 * When using the camera function, ensure that the camera and HMI are on the same LAN. When the HMI is directly connected to the camera through a network cable, set both HMI and camera to static IP addresses as follows.
772
773 (% class="table-bordered" %)
774 |=(% style="width: 166px;" %) |=(% style="width: 256px;" %)HMI|=(% style="width: 332px;" %)Camera
775 |(% style="width:166px" %)IP address|(% style="width:256px" %)192.168.1.1|(% style="width:332px" %)192.168.1.2
776 |(% style="width:166px" %)Gateway|(% style="width:256px" %)192.168.1.1|(% style="width:332px" %)192.168.1.1
777
778 * You could obtain the camera from the "Camera Search module" in "Project parameters" or manually fill in the address. You can obtain resources for the camera display object in the Camera Search module or manually enter the parameters.
779 * You are advised to configure and confirm the user name and password of the camera before using it. Do not use the wrong user name (password) to search for or link to the camera. Once the wrong user name (password) is exceeded for a certain number of times, the camera will be locked. During the lock period, the camera will reject any connection for at least half an hour generally.
780 * When monitoring HMI cameras, do not monitor the same camera at the same time. Otherwise, the monitoring screen may be lost.
781 * When the camera is disconnected due to network reasons, the system wouyld try to reconnect the camera every 20 seconds.
782 * The alias of the camera is saved in the user database. The alias in old project is retained when downloading new project, if [user database] is selected. Otherwise the it will be deleted.
783
784 (% style="text-align:center" %)
785 [[image:11.Advanced Function_html_804b6a35561fc436.png||height="367" width="600" class="img-thumbnail"]]
786
787 **Demo download link**
788
789 [[https:~~/~~/drive.google.com/open?id=10UR1cg8KDjcTvKJYgk1KR8z4YIApIsD8>>url:https://drive.google.com/open?id=10UR1cg8KDjcTvKJYgk1KR8z4YIApIsD8]]
790
791 = **LAN Monitoring** =
792
793 WECON provides [HMI Monitor System] software for user to monitor PI3000 series HMI in Local area network (LAN).
794
795 This function is only for the model with -O. For example PI3070N-O.
796
797 == **[HMI Monitor System] software** ==
798
799 **Device List: **It displays HMIs, that connected into this monitor software;
800
801 **State Indicator:** It shows state of HMI, green means online, gray means offline;
802
803 **Operation Buttons: **It provides three operations for HMI device;
804
805 * Add: Click it to open add setting window;
806 * Delete: Click it to delete selected HMI device;
807 * Monitor: Click it to open monitor window for selected HMI device;
808
809 (% style="text-align:center" %)
810 [[image:11.Advanced Function_html_fdfb5186d5dd123d.png||height="302" width="600" class="img-thumbnail"]]
811
812 == **Operating procedures** ==
813
814 Click [Add] button to open setting window;
815
816 Enter HMI IP and Note;
817
818 Click [Connection test] button;
819
820 * If IP is correct, it will display tip as below;
821
822 (% style="text-align:center" %)
823 [[image:11.Advanced Function_html_130ed411da07f4c4.png||height="376" width="550" class="img-thumbnail"]]
824
825 * If IP is incorrect, it will display tip as below
826
827 (% style="text-align:center" %)
828 [[image:11.Advanced Function_html_878d04362f1b81b6.png||height="122" width="150" class="img-thumbnail"]]
829
830 **✎Note:** For using this function in PC, it requires the setup of LAN Monitoring Firewall, using Windows 7 system as example. **If this function works well in your PC, please ignore below content.**
831
832 **Solution 1: Disable Firmware Completely**
833
834 Open "Control Panel" and select "System Security".
835
836 (% style="text-align:center" %)
837 [[image:11.Advanced Function_html_9616a538bd5b8890.png||height="426" width="600" class="img-thumbnail"]]
838
839 Select "Windows Firewall"
840
841 (% style="text-align:center" %)
842 [[image:11.Advanced Function_html_4ff5d9c605179616.png||height="427" width="600" class="img-thumbnail"]]
843
844 Select "turn Windows Firewall on or off"
845
846 (% style="text-align:center" %)
847 [[image:11.Advanced Function_html_8cce81685e77dd93.png||height="532" width="850" class="img-thumbnail"]]
848
849 Select "Turn off Windows Firewall"
850
851 (% style="text-align:center" %)
852 [[image:11.Advanced Function_html_8e40bd24335bee5f.png||height="451" width="700" class="img-thumbnail"]]
853
854 **Solution 2: Do not close the firewall, but allow HMIUI to pass through the firewall**
855
856 Open Control Panel selection "system Security"
857
858 (% style="text-align:center" %)
859 [[image:11.Advanced Function_html_4a5370b15f8344bf.png||height="363" width="550" class="img-thumbnail"]]
860
861 Select "Windows Firewall"
862
863 (% style="text-align:center" %)
864 [[image:11.Advanced Function_html_3f00b4c76667d218.png||height="394" width="600" class="img-thumbnail"]]
865
866 Select "run a program or function through Windows Firewall"
867
868 (% style="text-align:center" %)
869 [[image:11.Advanced Function_html_2ce833853fe2fe08.png||height="422" width="600" class="img-thumbnail"]]
870
871 Select "Allow to run another program".
872
873 (% style="text-align:center" %)
874 [[image:11.Advanced Function_html_49e43fd3e9e58bc3.png||height="401" width="600" class="img-thumbnail"]]
875
876 Select "browse" in the pop-up dialog box.
877
878 (% style="text-align:center" %)
879 [[image:11.Advanced Function_html_714b05b4f66641fb.png||height="447" width="450"]]
880
881 Locate the HMIUI.exe file in the HMIUI directory under the installation path of the monitoring software, and double-click HMIUI.exe.
882
883 (% style="text-align:center" %)
884 [[image:11.Advanced Function_html_cdf52e5522e2e568.png||height="596" width="600" class="img-thumbnail"]]
885
886 Select "add".
887
888 (% style="text-align:center" %)
889 [[image:11.Advanced Function_html_2cf5b5f0c9aa4f7a.png||height="467" width="535" class="img-thumbnail"]]
890
891 Check the corresponding options.
892
893 (% style="text-align:center" %)
894 [[image:11.Advanced Function_html_ffc611cca1a173f9.png||height="361" width="600" class="img-thumbnail"]]
895
896 select "OK".
897
898 (% style="text-align:center" %)
899 [[image:11.Advanced Function_html_934ebd63c53af3ee.png||height="442" width="600" class="img-thumbnail"]]
900
901 = **Remote access config** =
902
903 **Introduction**
904
905 In the traditional concept, it is rather Difficult and complicated to remotely connect HMI via Ethernet. Users not only need to consider the security issue, but also need to set up complex network parameters. In addition, subject to the stage of the network environment, users have to do everything possible to think of ways through all levels of routers and switches. And an independent IP could only correspond to one HMI in tradition sense of the remote control. The WECON remote access system will solve all of those problems.
906
907 The solution of WECON HMI remote access is "Everything is possible with one network, one HMI, one cable". No matter where the HMI is, users could easily remote access HMI through the network, to achieve exclude exceptions and resolve them in the first time. In local area network or remote Internet, users could make HMI connect to Ethernet by one cable without setting any parameters. All network settings could be set by WECON remote access system.
908
909 **Set the IP of HMI**
910
911 (% style="text-align:center" %)
912 [[image:远程访问 1.png||class="img-thumbnail"]]
913
914 **Use mobile phones, computers, tablets, etc., open a browser, enter the IP, you could access the project in the HMI screen.**
915
916 * You are advised to use Chrome or Firefox. If you want to use Internet Explorer, use Internet Explorer 9 or later.
917 * 360, Sogou and other browsers need to use speed mode.
918 * Support the iphone's own browser, or install a latest UC browser.
919 * As long as the browser supports HTML5.
920
921 **Access through the cloud**
922
923 Access through the cloud platform, enter the machine code (the machine code of each HMI is independent) and model, then monitor the HMI remotely.
924
925 **Access through V-NET (ig series)**
926
927 Access through the V-NET, enter the machine code (the machine code of each HMI is independent) and the device password, bind the HMI, and monitor the HMI remotely.
928
929 **System Components**
930
931 WECON PI8000 and advanced HMI with [-R], such as PI8070-R;
932
933 WECON Smart APP or WECON Cloud platform
934
935 **User manual for WECON Smart and cloud platform download link**
936
937 [[https:~~/~~/drive.google.com/open?id=1hI8QI4vmJhAis2GFuCISChV9xGU0BxQ9>>url:https://drive.google.com/open?id=1hI8QI4vmJhAis2GFuCISChV9xGU0BxQ9]]
938
939 **FAQ**
940
941 * What is the difference between the-R model and the normal model?
942 ** The-R model can be accessed directly and unrestricted. Normal models need to buy cloudmonitoring products before access. The number of monitoring normal model is limitedaccording to the customer's purchase of cloud monitor packages.
943 * How many customers could remote access HMI at the same time?
944 ** It supports max. 4 customers access HMI in the same time.
945
946 = **Mulit-link** =
947
948 == **Introduction** ==
949
950 The main principle of Multi-link is to use the method of Master&Slave to implement the One machine-Multiple screens by ethernet port. For example, one Master HMI connect to one Slave HMI, the Slave one can write or read value from PLC which is communicated with Master.
951
952 In Multi-link, there is only one Master, and all the other HMIs are Slaves. The Master HMI is the only one device communicate with PLC, and the data received from the PLC is transmitted to each slave through the host HMI(Master).
953
954 (% style="text-align:center" %)
955 [[image:1652345241521-592.png||class="img-thumbnail"]]
956
957 At present, the Multi-link is regarded as special function. So not any model HMI support it. Need the HMI come with the special machine code. The series support Multi-link function right now: General, HMI+, i Series. Multi link doesn’t support the online simulaion. PI3000/PI3000+/PI3000i series can only have one Slave when using this function, while PI8000/9000,PI8000+/PI9000+ series can use at most 5 Slaves.
958
959 == **PIStudio settings** ==
960
961 Check to enable Multi-link, select the corresponding option. For example, if it is a slave HMI, select Slave.
962
963 (% style="text-align:center" %)
964 [[image:多机互联.png||class="img-thumbnail"]]
965
966
967 (% class="wikigeneratedid" %)
968 Master IP address setting: Click "Project"→"Project settings"→"HMI IP", as below.
969
970 (% style="text-align:center" %)
971 [[image:远程访问 1.png||height="516" width="594" class="img-thumbnail"]]
972
973 == **Slave project** ==
974
975 In order to let the fonts in the Slave and the Master consistent with each others, so Slave project needs to add one screen that can set the IP address of Master HMI for connecting to the Master, on the original the Master project. If Master project has components that use other font styles, and Slave project If there is no component corresponding to Master project, then the default font style SimSun would be displayed when the Multi-link is enabled. To avoid the Slave device prompts communication timeout message, you can add HSW9 = 1 in the initial script of Slave device.
976
977 == **Address** ==
978
979 |Address|Address Description|Usage Method
980 |HSW1100|(% rowspan="4" %)The IP of Master HMI|IP address high endian 1
981 |HSW1101|IP address high endian 2
982 |HSW1102|IP address high endian 3
983 |HSW1103|IP address high endian 4
984 |HSW1104|(((
985 Control the Slave to connect to
986
987 the Master or not
988 )))|(((
989 1: Connect to Master
990
991 0: Disconnect
992 )))
993
994 == **Notice** ==
995
996 During the connection, if the Master is downloading program, there is a highly chances that the slave screen is abnormal, and the Gallery and imported pictures cannot be displayed.
997
998 After the download process of Master HMI is finished, Slave needs to be restarted to monitor normally.
999
1000 * If the Master and Slave are operated on any screen, the screen also will follow the changes and synchronize for other side.
1001 ** Using HSW12 = 1 on the Master, which can not affect each other.
1002 * There is no momentary delay function for buttons.
1003 * Multi-link version bit switch has no Min. holding time.
1004 * PI3000 series can only have one Slave when using this function, while PI8000/9000 series can use this function at most 5 Slaves.
1005 * Only supports Multi-link connection in the LAN network (local area network), or direct connection between Master and Slave.
1006 * The Master and Slave projects must be consistent (mainly for keeping the font style used by the Master and Slave HMI consistent), and the Slave HMI always adds the configuration of the “Master IP address".
1007 * After the special address is enabled, Slave will remotely monitor the interfaces from Master, and the source project will not be executed.
1008
1009 ✎Note: Slave project only needs to ensure that there is "the HSW address of the Master HMI IP" and the font style used by the Master.
1010
1011 = **V-NET Access (PC Side)** =
1012
1013 == **Login interface** ==
1014
1015 Enter the platform, as shown in Figure 1:
1016
1017 New users need to register first.
1018
1019 * The successfully registered account is the administrator account, which can bind the device and other operations.
1020 * The user needs to remember the registered account and password, and able to log in simultaneously on the PC Client/APP.
1021 * If the user forgets the password, he can click "Forgot Password" to reconfigure the password.
1022
1023 (% style="text-align:center" %)
1024 [[image:11.2-1.png||class="img-thumbnail"]]
1025
1026 Figure 1
1027
1028 Enter the account and password, and then click the "Login" button.
1029
1030 After successfully logging in, enter the "V-NET" interface, as shown in Figure 2. Add the HMI information you want to access through the "+" in the lower left corner.
1031
1032 (% style="text-align:center" %)
1033 [[image:11.Advanced Function_html_7618c4f92465545c.png||height="670" width="1366" class="img-thumbnail"]]
1034
1035 Figure 2
1036
1037 After the Add Device window pops up, enter the machine code and password of the device to add the device, as shown in Figure 3:   
1038
1039 (% style="text-align:center" %)
1040 [[image:11.Advanced Function_html_9b4cc907cf4a8c13.png||height="502" width="601" class="img-thumbnail"]]
1041
1042 Figure 3
1043
1044 * **Device machine code:** Each HMI has a unique and independent machine code, which is used to identify every remote device. (When binding multiple devices at the same time, the device passwords must be the same. Only one machine code can be entered on one line. When entering multiple machine codes, use the "Enter" key to change the line. If the format is wrong, the binding operation will fail and error will occur). Method of obtain machine code:
1045 ** PIStudio → "Project" → "Tool"→ "Download" →Copy the machine code.        
1046 ** Long press the upper right corner of HMI to enter the backstage, you can see "Machine Id" in "Machine Info".       
1047 ** Obtain the machine code from the backlabel of the device.
1048 * **Device password**: Refers to the Cloud access password, the default is 6 digits 8 (888888). Please refer to the cloud configuration if you first time binding the device.
1049 ** The length is 6 digits, English and special characters in English are allowed, spaces are not allowed, and cannot be empty.
1050 * **Device alias:** Refers to the name recognition of device in the menu bar of V-NET.
1051 ** Maximum 12 digits, except ·_-+=}]",.?,;: ""”【】—()...! these Special characters allowed others are limited to input, no spaces or blanks are allowed.
1052 ** If the device is successfully bound, click OK, and it would prompt message: The device is bound successfully!
1053
1054 (% class="box infomessage" %)
1055 (((
1056 **✎Note: **If you bind multiple machine codes in batch, the device alias will use the input device alias as the prefix, and the system will automatically add a suffix. Example: Default group (device alias)_1 (automatically added suffix).
1057 )))
1058
1059 == **V-NET module** ==
1060
1061 **Remote Monitoring**
1062
1063 The remote monitoring module can display the project page of the current screen in real time, and can operate the project on the web page, and the control of the screen. As shown in Figure 4:
1064
1065 (% style="text-align:center" %)
1066 [[image:11.2-4.png||class="img-thumbnail"]]
1067
1068 Figure 4
1069
1070 **Data Viewing**
1071
1072 The data viewing module is divided into Communication port, Collection point, Alarm configuration, Alarm records, Data Record configuration , Data Record, etc. As shown in Figure 5:
1073
1074 (% style="text-align:center" %)
1075 [[image:11.2-5.png||class="img-thumbnail"]]
1076
1077 Figure 5
1078
1079 The parameter configuration is as follows:
1080
1081 * Communication port : The communication port information, includes connection method and protocol name, can only be viewed, and cannot be added or modified. This info comes from the settings from HMI.
1082 * Collect point:Data monitoring module of the device. The collection point is the monitoring data, and its read-write, write-only, and read-only permissions also come from the Tags settings from HMI.
1083 * Note: You cannot add or delete collection points here. The read & write permissions of the collection points in the HMI will directly restrict the modification of the read & write permissions of the collection points by V-NET.
1084 * Alarm configuration: Alarm records of the device, monitoring points cannot be added, confirming the Alarm record and exporting data can be performed.
1085 * Data Record configuration: Data Record is historical data of the device, monitoring points cannot be added, curve and list viewing method are supported, and data records can be exported.
1086
1087 **Remote Download**
1088
1089 This function allows application on the PC to download directly to PLC or HMI, as shown in Figure 6:
1090
1091 (% style="text-align:center" %)
1092 [[image:11.2-6.png||class="img-thumbnail"]]
1093
1094 Figure 6
1095
1096 (% class="box infomessage" %)
1097 (((
1098 **✎Note: **The pass through function of remote download is temporarily unavailable on the web page, and it can be used normally in PC client. The configuration is as follows:
1099 )))
1100
1101 PLC download (only for Pass-through)
1102
1103 * Click the setting (gear icon) in the upper right corner of PC Client, and a dialog will pop up. The red area is the COM port configuration when the PLC pass-through downloads. As shown in Figure 7:
1104
1105 (% style="text-align:center" %)
1106 [[image:11.Advanced Function_html_870ebc5415b1a534.png||height="565" width="526" class="img-thumbnail"]]
1107
1108 Figure 7
1109
1110 * After configuring the COM port, go to the remote downloaded, PLC download, to config the name, communication port, virtual serial port and other configurations as shown in Figure 6.
1111
1112 HMI Download (only for Pass-through)
1113
1114 * Click the setting (gear icon) button in the upper right corner of PC Client, and a dialog will pop up. The red area is the configuration of the HMI download tool. As shown in Figure 8:
1115
1116 (% style="text-align:center" %)
1117 [[image:11.Advanced Function_html_64e406f9862f887e.png||height="565" width="526" class="img-thumbnail"]]
1118
1119 Figure 8
1120
1121 * Click the setting (gear icon) button, a dialog box will pop up, and automatically detect and find the PIStudio that has been installed in PC and conforms to the version, as shown in Figure 9:
1122 ** Location: Display the installation path of the current PIStudio.
1123 ** Version: Corresponding to the version of the current PIStudio.
1124 ** Browse: Click to manually set the installation path of PIStudio.
1125
1126 [[image:11.Advanced Function_html_df9946a5a7574454.png||height="349" width="642"]]
1127
1128 Figure 9
1129
1130 **Basic**
1131
1132 In the "Basic" sub-page of Basic, HMI name, record reserved selection, password, location and remarks, etc. As shown in Figure 10:
1133
1134 [[image:11.Advanced Function_html_c76828978cb6b697.png||height="670" width="1366"]] Figure 10
1135
1136 The device name is an alias of HMI, which is mainly used for easy distinction.
1137
1138 Online status: You can click the refresh button to refresh the online status of the HMI.
1139
1140 Machine code: Each HMI has a unique and independent machine code.
1141
1142 Record reserved: Checking the corresponding options will let HMI to suspend updating the corresponding configuration after downloading a new project.
1143
1144 Password: Refers to the cloud access password, the default is 6 digits 8 (888888); the cloud access password can be set and modified, the specific location is:
1145
1146 * V-NET → specified HMI → Baisc → "password” → modify and save, as shown in Figure 10.        
1147 * "Project" → "Cloud" → "Basic" → "Password" → of PIStudio (only unbind HMI can be modified), see Cloud Configuration.
1148
1149 Maximum storage of Alarm data: The maximum number of alarm data saved, with a range of 1 to 50000.    
1150
1151 Positioning:
1152
1153 * Use the device base station positioning to locate.        
1154 * Use manual positioning.
1155
1156 (% class="box infomessage" %)